Lung monitoring at the bedside in mechanically ventilated patients

Purpose of reviewIt has become clear that mechanical ventilation itself can cause damage to the lung in critically ill patients, also known as ventilator-induced lung injury (VILI). Insight into the mechanisms of VILI has learned that a compromise must be found between positive end-expiratory pressure (PEEP) induced alveolar recruitment and prevention of hyperinflation. Therefore, there is a need for clinicians to optimize the PEEP settings for the individual patient at the bedside. In this review, we will discuss several lung-monitoring techniques to improve patient ventilator settings. Recent findingsRecently, new monitoring tools like electrical impedance tomography (EIT), vibration response imaging, respiratory inductive plethysmography and functional residual capacity (FRC) have been (re-)introduced in our ICU. Nowadays, FRC can be measured without the use of tracer gases and without disconnection from the ventilator. EIT is another noninvasive bedside monitoring tool that provides regional ventilation distribution images and can be used for qualitative and quantitative assessment of regional change in ventilation after a ventilator change. These new noninvasive techniques are discussed and seem promising to help clinicians to improve their ventilator settings in the individual patient at the bedside. SummaryIn conclusion, both FRC and EIT are promising clinical monitoring systems but clinical studies are needed to prove whether these monitors help the clinician toward effective and better ventilator management.

[1]  J. Nunn,et al.  Functional residual capacity during anaesthesia. I: Methodology. , 1974, British journal of anaesthesia.

[2]  Ilya Kagan,et al.  Computerized Lung Acoustic Monitoring Can Help to Differentiate between Various Chest Radiographic Densities in Critically Ill Patients , 2010, Respiration.

[3]  J. Ibáñez,et al.  Normal values of functional residual capacity in the sitting and supine positions , 2005, Intensive Care Medicine.

[4]  W. Brunow de Carvalho,et al.  Electric impedance tomography, the final frontier is close: the bedside reality. , 2007, Critical care medicine.

[5]  C Weissman,et al.  Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume. , 1992, Chest.

[6]  Matthias Briel,et al.  Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: systematic review and meta-analysis. , 2010, JAMA.

[7]  Jordi Mancebo,et al.  PEEP-induced changes in lung volume in acute respiratory distress syndrome. Two methods to estimate alveolar recruitment , 2011, Intensive Care Medicine.

[8]  S. Bohm,et al.  Compliance and Dead Space Fraction Indicate an Optimal Level of Positive End-Expiratory Pressure After Recruitment in Anesthetized Patients , 2008, Anesthesia and analgesia.

[9]  Steffen Leonhardt,et al.  Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography , 2008, Intensive Care Medicine.

[10]  S. Lundin,et al.  Validation and clinical feasibility of nitrogen washin/washout functional residual capacity measurements in children , 2010, Acta anaesthesiologica Scandinavica.

[11]  Diederik Gommers,et al.  End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions , 2008, Critical care.

[12]  S. Lundin,et al.  Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction , 2005, Anesthesia and analgesia.

[13]  J. M. Raurich,et al.  A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation. , 1982, Critical care medicine.

[14]  J. Bakker,et al.  Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial , 2011, Critical care.

[15]  S. Leonhardt,et al.  Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients , 2010, Critical care.

[16]  S. Lundin,et al.  Positive end‐expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery , 2006, Acta anaesthesiologica Scandinavica.

[17]  D. Schoenfeld,et al.  Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. , 2000, The New England journal of medicine.

[18]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[19]  Marek Ancukiewicz,et al.  Higher versus lower positive end-expiratory pressures in patients with the acute respiratory distress syndrome. , 2009, The New England journal of medicine.

[20]  Steffen Leonhardt,et al.  Experimental case report: development of a pneumothorax monitored by electrical impedance tomography , 2009, Clinical physiology and functional imaging.

[21]  K. Lowhagen,et al.  Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography. , 2010, Minerva anestesiologica.

[22]  Christian Putensen,et al.  Electrical impedance tomography guided ventilation therapy , 2007, Current opinion in critical care.

[23]  S. Leonhardt,et al.  Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels , 2009, Intensive Care Medicine.

[24]  J. Bakker,et al.  Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation , 2009, Intensive Care Medicine.

[25]  Guillermo Bugedo,et al.  Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome* , 2008, Critical care medicine.

[26]  Yael A. Glickman,et al.  Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode , 2007, Critical care.

[27]  D. Chiumello,et al.  Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume , 2008, Critical Care.

[28]  Josep Solà,et al.  Heart-lung interactions measured by electrical impedance tomography* , 2011, Critical care medicine.

[29]  C. Putensen,et al.  Meta-analysis: Ventilation Strategies and Outcomes of the Acute Respiratory Distress Syndrome and Acute Lung Injury , 2009, Annals of Internal Medicine.

[30]  G. Hedenstierna Using electric impedance tomography to assess regional ventilation at the bedside. , 2004, American journal of respiratory and critical care medicine.

[31]  Marcelo B. P. Amato,et al.  Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography , 2009, Intensive Care Medicine.

[32]  G. Hedenstierna,et al.  The effects of anesthesia and muscle paralysis on the respiratory system , 2005, Intensive Care Medicine.

[33]  Respiratory-inductive-plethysmography-derived flow can be a useful clinical tool to detect patients with obstructive sleep apnea syndrome. , 2011, Journal of the Formosan Medical Association = Taiwan yi zhi.