High-throughput semi-automated 96-well liquid/liquid extraction and liquid chromatography/mass spectrometric analysis of everolimus (RAD 001) and cyclosporin a (CsA) in whole blood.

A semi-automated high-throughput liquid/liquid extraction (LLE) assay was developed for RAD001 and cyclosporin A (CsA) in human blood. After addition of internal standard and ammonium hydroxide, samples were extracted twice with methyl tert-butyl ether (MTBE). The organic extract was evaporated to dryness and reconstituted in mobile phase. Where possible, sample transfer and LLE steps were automated using a Tomtec Quadra 96 workstation. Samples were analyzed using ESI-LC/MS/MS employing the transitions of ([M + NH(4)](+) --> [M + H](+)) for CsA and ([M + NH(4)](+) --> [M + H-(CH(3)OH + H(2)O)](+)) for RAD001, under isocratic chromatographic conditions (75:25, (v/v), acetonitrile/20 mM ammonium acetate) with a run time of 3.6 min. A lower limit of quantitation (LLOQ) of 0.368 ng/mL and 5.23 ng/mL was achieved for RAD001 and CsA, respectively, using a sample volume of 0.3 mL for the analysis. The method was validated over a 3-day period and the resulting calibration curves had a correlation coefficient >0.99 over the concentration range 0.368 to 409 ng/mL and 5.24 to 1748 ng/mL for RAD001 and CsA, respectively. The inter-day coefficient of variation (CV) was less than 15% at the LLOQ for both compounds. The method was applied to the analysis of clinical samples. Under normal working conditions four 96-well plates could be extracted and LC/MS analysis completed in less than 28 h. A marked improvement in sample throughput efficiency was realized with this LLE method when compared to existing solid phase extraction (SPE) methods which deal with both RAD001 and CsA.

[1]  P. Taylor,et al.  Quantitative analysis of sirolimus (Rapamycin) in blood by high-performance liquid chromatography-electrospray tandem mass spectrometry. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[2]  U. Christians,et al.  Simultaneous on-line extraction and analysis of sirolimus (rapamycin) and ciclosporin in blood by liquid chromatography-electrospray mass spectrometry. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[3]  G. Berry,et al.  Coadministration of neoral and the novel rapamycin analog, SDZ RAD, to rat lung allograft recipients: potentiation of immunosuppressive efficacy and improvement of tolerability of staggered versus simultaneous treatment. , 1999, Transplantation.

[4]  L M McMahon,et al.  High-throughput analysis of everolimus (RAD001) and cyclosporin A (CsA) in whole blood by liquid chromatography/mass spectrometry using a semi-automated 96-well solid-phase extraction system. , 2000, Rapid communications in mass spectrometry : RCM.

[5]  D. Holt,et al.  Consensus Guidelines for Therapeutic Drug Monitoring of Rapamycin: Report of the Consensus Panel , 1995, Therapeutic drug monitoring.

[6]  K. Sewing,et al.  Automated simultaneous quantification of the immunosuppressants 40-O-(2-hydroxyethyl) rapamycin and cyclosporine in blood with electrospray-mass spectrometric detection. , 1998, Clinical chemistry.

[7]  Z. Ouyang,et al.  Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by high-performance liquid chromatography with tandem mass spectrometry. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[8]  T. Meerloo,et al.  SDZ RAD, a new rapamycin derivative: synergism with cyclosporine. , 1997, Transplantation.

[9]  U. Christians,et al.  Development of a high-performance liquid chromatographic-electrospray mass spectrometric assay for the specific and sensitive quantification of the novel immunosuppressive macrolide 40-O-(2-hydroxyethyl)rapamycin. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[10]  G. Berry,et al.  Tissue distribution and clinical monitoring of the novel macrolide immunosuppressant SDZ-RAD and its metabolites in monkey lung transplant recipients: interaction with cyclosporine. , 2000, The Journal of pharmacology and experimental therapeutics.

[11]  W. Jacobsen,et al.  LC/ESI-MS allows simultaneous and specific quantification of SDZ RAD and cyclosporine, including groups of their metabolites in human blood. , 1999, Therapeutic drug monitoring.

[12]  J. Henion,et al.  Quantitative liquid chromatographic-tandem mass spectrometric determination of reserpine in FVB/N mouse plasma using a "chelating" agent (disodium EDTA) for releasing protein-bound analytes during 96-well liquid-liquid extraction. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[13]  K. Sewing,et al.  Structural elucidation by electrospray mass spectrometry: An approach to the in vitro metabolism of the macrolide immunosuppressant SDZ RAD , 1998, Journal of the American Society for Mass Spectrometry.

[14]  F. Tse,et al.  Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin) in human plasma. , 2000, Rapid communications in mass spectrometry : RCM.

[15]  M. Oellerich,et al.  Lake Louise Consensus Conference on Cyclosporin Monitoring in Organ Transplantation: Report of the Consensus Panel , 1995, Therapeutic drug monitoring.

[16]  J. Henion,et al.  High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12 hours. , 1999, Analytical Chemistry.

[17]  J. Henion,et al.  Liquid-liquid extraction in the 96-well plate format with SRM LC/MS quantitative determination of methotrexate and its major metabolite in human plasma. , 1999, Analytical chemistry.

[18]  M. Manns,et al.  Automated, fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: immunosuppressants. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[19]  K. Hoffman,et al.  Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids. , 2000, Journal of pharmaceutical and biomedical analysis.

[20]  J. Henion,et al.  Bioanalytical high-throughput selected reaction monitoring-LC/MS determination of selected estrogen receptor modulators in human plasma: 2000 samples/day. , 2000, Analytical chemistry.

[21]  C. Campañá,et al.  Clinically Significant Drug Interactions with Cyclosporin An Update , 1996, Clinical pharmacokinetics.