PPG motion artifact handling using a self-mixing interferometric sensor

Pulse oximeters measure a patient's heart rate and blood oxygenation by illuminating the skin and measuring the intensity of the light that has propagated through it. The measured intensities, called photoplethysmograms (PPGs), are highly susceptible to motion, which can distort the PPG derived data. Part of the motion artifacts are considered to result from sensor deformation, leading to a change in emitter-detector distance. It is hypothesized that these motion artifacts correlate to movement of the emitter with respect to the skin. This has been investigated in a laboratory setup in which motion artifacts can be reproducibly generated by translating the emitter with respect to a flowcell that models skin perfusion. The top of the flowcell is a diffuse scattering Delrin skin phantom under which a cardiac induced blood pulse is modeled by a changing milk volume. By illuminating the flowcell, a PPG can be measured. The emitter's translation has been accurately measured using self-mixing interferometry (SMI). The motion artifacts in the PPG as a result of emitter motion are shown to correlate with the emitter's displacement. Moreover, it is shown that these artifacts are significantly reduced by a least-mean-square algorithm that uses the emitter's displacement measured via SMI as artifact reference.

[1]  P. D. de Groot,et al.  Ranging and velocimetry signal generation in a backscatter-modulated laser diode. , 1988, Applied optics.

[2]  M. H. Koelink,et al.  Laser Doppler velocimeter based on the self-mixing effect in a fiber-coupled semiconductor laser: theory. , 1992, Applied optics.

[3]  M. Michalski,et al.  Optical parameters of milk fat globules for laser light scattering measurements , 2001 .

[4]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[5]  P. Mannheimer,et al.  The Light–Tissue Interaction of Pulse Oximetry , 2007, Anesthesia and analgesia.

[6]  Paolo Bonato,et al.  Wearable Sensors and Systems , 2010, IEEE Engineering in Medicine and Biology Magazine.

[7]  S. Thomas Alexander,et al.  Adaptive Signal Processing , 1986, Texts and Monographs in Computer Science.

[8]  K. Petermann Laser Diode Modulation and Noise , 1988 .

[9]  M. J. Hayes,et al.  Artefact reduction in photoplethysmography , 1998 .

[10]  John M. Graybeal,et al.  The Effect of Motion on Pulse Oximetry and Its Clinical Significance , 2007, Anesthesia and analgesia.

[11]  J. Muehlsteff,et al.  The Challenge of Motion Artifact Suppression in Wearable Monitoring Solutions , 2006, 2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors.

[12]  P. Å. Öberg,et al.  Accuracy of pulse oximetry at various haematocrits and during haemolysis in anin vitro model , 1993, Medical and Biological Engineering and Computing.

[13]  I M Braverman,et al.  The cutaneous microcirculation. , 2000, The journal of investigative dermatology. Symposium proceedings.

[14]  G. Soelkner,et al.  Experimental and theoretical laser-Doppler frequency spectra of a tissuelike model of a human head with capillaries. , 1999, Applied optics.

[15]  H Harry Asada,et al.  Mobile monitoring with wearable photoplethysmographic biosensors. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.