BIACORE data processing: an evaluation of the global fitting procedure.

Data from real-time molecular interaction analysis using BIACORE are currently evaluated by numerical integration. We have investigated the ability of two software packages (BIAevaluation 3.0 and CLAMP99) to analyze complex interactions. Three experimental data sets of high quality obtained with BIACORE upgraded and 2000 instruments, representative of simple bimolecular, heterogeneous ligand, and mass-transport-limited interactions, were processed by the global fitting procedure. The two software, which differ mainly in the statistical assessment of the output values, were able to discriminate correctly between various interacting models and provided very close output parameters with satisfactory statistical tests.

[1]  M. O’Connor-McCourt,et al.  Real-time kinetic studies on the interaction of transforming growth factor alpha with the epidermal growth factor receptor extracellular domain reveal a conformational change model. , 2000, Biochemistry.

[2]  Laurence Choulier,et al.  Effects on interaction kinetics of mutations at the VH–VL interface of Fabs depend on the structural context , 2000, Journal of molecular recognition : JMR.

[3]  S. Smith‐Gill,et al.  Experimental design for analysis of complex kinetics using surface plasmon resonance. , 2000, Methods.

[4]  D. Myszka,et al.  Improving biosensor analysis , 1999, Journal of molecular recognition : JMR.

[5]  J. Witz Kinetic analysis of analyte binding by optical biosensors: hydrodynamic penetration of the analyte flow into the polymer matrix reduces the influence of mass transport. , 1999, Analytical biochemistry.

[6]  D. Millar,et al.  Determination of binding constants by equilibrium titration with circulating sample in a surface plasmon resonance biosensor. , 1998, Analytical biochemistry.

[7]  M. Doyle,et al.  Interpreting kinetic rate constants from optical biosensor data recorded on a decaying surface. , 1998, Analytical biochemistry.

[8]  D G Myszka,et al.  Extending the range of rate constants available from BIACORE: interpreting mass transport-influenced binding data. , 1998, Biophysical journal.

[9]  H. Lortat-Jacob,et al.  The Heparan Sulfate Binding Sequence of Interferon-γ Increased the On Rate of the Interferon-γ-Interferon-γ Receptor Complex Formation* , 1998, The Journal of Biological Chemistry.

[10]  R. Fisher,et al.  BIAcore for macromolecular interaction. , 1998, Current opinion in biotechnology.

[11]  D G Myszka,et al.  Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors. , 1997, Methods in enzymology.

[12]  R. Karlsson,et al.  Biomolecular interaction analysis: affinity biosensor technologies for functional analysis of proteins. , 1997, Current opinion in chemical biology.

[13]  P. Schuck,et al.  Reliable determination of binding affinity and kinetics using surface plasmon resonance biosensors. , 1997, Current opinion in biotechnology.

[14]  M. V. Van Regenmortel,et al.  Concentration measurement of unpurified proteins using biosensor technology under conditions of partial mass transport limitation. , 1997, Analytical biochemistry.

[15]  M. Doyle,et al.  Kinetic analysis of a protein antigen-antibody interaction limited by mass transport on an optical biosensor. , 1997, Biophysical chemistry.

[16]  D. Myszka,et al.  Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors. , 1997, Current opinion in biotechnology.

[17]  R. Karlsson,et al.  Experimental design for kinetic analysis of protein-protein interactions with surface plasmon resonance biosensors. , 1997, Journal of immunological methods.

[18]  D Altschuh,et al.  Functional mapping of conserved residues located at the VL and VH domain interface of a Fab. , 1996, Journal of molecular biology.

[19]  D G Myszka,et al.  Global analysis of a macromolecular interaction measured on BIAcore. , 1996, Biochemical and biophysical research communications.

[20]  D. Winzor,et al.  Interpretation of deviations from pseudo-first-order kinetic behavior in the characterization of ligand binding by biosensor technology. , 1996, Analytical biochemistry.

[21]  H. Le,et al.  Human interleukin 4 receptor complex: neutralization effect of two monoclonal antibodies. , 1996, Biochemistry.

[22]  G. Hausdorf,et al.  Binding kinetics of an antibody against HIV p24 core protein measured with real-time biomolecular interaction analysis suggest a slow conformational change in antigen p24. , 1996, Journal of immunological methods.

[23]  I. Chaiken,et al.  Interpreting complex binding kinetics from optical biosensors: a comparison of analysis by linearization, the integrated rate equation, and numerical integration. , 1995, Analytical biochemistry.

[24]  J. Erickson,et al.  Real‐time DNA binding measurements of the ETSl recombinant oncoproteins reveal significant kinetic differences between the p42 and p51 isoforms , 1994, Protein science : a publication of the Protein Society.

[25]  I. Brooks,et al.  Determination of rate and equilibrium binding constants for macromolecular interactions using surface plasmon resonance: use of nonlinear least squares analysis methods. , 1993, Analytical biochemistry.

[26]  D. Altschuh,et al.  Interaction of cyclosporin A with an Fab fragment or cyclophilin Affinity measurements and time‐dependent changes in binding , 1993, FEBS letters.

[27]  D. Altschuh,et al.  Determination of kinetic constants for the interaction between a monoclonal antibody and peptides using surface plasmon resonance. , 1992, Biochemistry.

[28]  J M Beechem,et al.  Global analysis of biochemical and biophysical data. , 1992, Methods in enzymology.

[29]  R. Karlsson,et al.  Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system. , 1991, Journal of immunological methods.

[30]  R. Karlsson,et al.  Real-time biospecific interaction analysis using surface plasmon resonance and a sensor chip technology. , 1991, BioTechniques.

[31]  S. Loefas,et al.  Immobilization of proteins to a carboxymethyldextran-modified gold surface for biospecific interaction analysis in surface plasmon resonance sensors. , 1991, Analytical biochemistry.