Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection

The precise sizing of the stent graft in thoracic endovascular aortic repair (TEVAR) affects aortic remodeling and hence, further outcome. Covering the proximal entry tear is essential for successful treatment of Type B aortic dissection. Intravascular ultrasound (IVUS) enables real-time aortic diameter assessment, and is especially useful when computed tomography (CT) image quality is poor. IVUS, however, is not routinely utilized due to cost inefficiency. We investigated the impact of IVUS-assisted stent graft sizing on aortic remodeling in TEVAR. In this single-center retrospective study we evaluated patients with Type B aortic dissection undergoing both CT and IVUS before TEVAR. We assessed the aortic diameter at the level of the left subclavian artery via both methods before stent implantation and analyzed due to which method the implanted stent graft was chosen, retrospectively. To determine the degrees of aortic remodeling involved, we evaluated true lumen and false lumen diameters, and total aortic remodeling in CT. We analyzed 45 patients with Type B aortic dissection undergoing TEVAR. The mean ages were 66.9±10.0 years fo0072 IVUS (n = 20) and 62.3±14.2 years for CT-assisted TEVAR (n = 25; p = 0.226). The follow-up time for both groups did not differ between the two groups (IVUS: 22.9±23.1 months, CT: 25.6±23.0 months; p = 0.700). While both methods were associated with advantages regarding aortic remodeling, IVUS-assisted sizing yielded a greater increase in true lumen (30.4±6.2 vs. 25.6±5.3; p = 0.008) and reductions in false lumen (14.4±8.5 vs. 23.9±9.3; p = 0.001) and total aortic diameter (35.5±6.0 vs. 39.9±8.1; p = 0.045). IVUS-guided stent graft sizing in Type B aortic dissection shows beneficial effects on aortic remodeling and might be of additional advantage in aortic diseases, especially when CT image quality is poor.

[1]  Po-Lin Chen,et al.  The Impact of Distal Stent Graft-Induced New Entry on Aortic Remodeling of Chronic Type B Dissection. , 2017, The Annals of thoracic surgery.

[2]  J. Binongo,et al.  Aortic Remodeling After Endovascular Repair of Complicated Acute Type B Aortic Dissection. , 2017, The Annals of thoracic surgery.

[3]  M. Farber,et al.  Management of acute type B aortic dissections , 2016, Expert review of cardiovascular therapy.

[4]  Zhenyu Shi,et al.  Outcomes and aortic remodelling after proximal thoracic endovascular aortic repair of post type B aortic dissection thoracic aneurysm. , 2016, VASA. Zeitschrift fur Gefasskrankheiten.

[5]  S. Puppala,et al.  Acute aortic syndrome—pitfalls on gated and non-gated CT scan , 2016, Emergency Radiology.

[6]  M. Ciccone,et al.  Advances in the diagnosis of acute aortic syndromes: Role of imaging techniques , 2016, Vascular medicine.

[7]  R. Erbel,et al.  Validation of intravascular ultrasound for measurement of aortic diameters: Comparison with multi-detector computed tomography , 2015, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[8]  T. Hatsukami,et al.  Intravascular ultrasound is a critical tool for accurate endograft sizing in the management of blunt thoracic aortic injury. , 2015, Journal of vascular surgery.

[9]  R. Erbel,et al.  PERIPHERAL VASCULAR DISEASE Original Studies Thoracic Aortic Aneurysm Expansion Due to Late Distal Stent Graft-Induced New Entry , 2015 .

[10]  L. Lönn,et al.  Endovascular repair of acute uncomplicated aortic type B dissection promotes aortic remodelling: 1 year results of the ADSORB trial. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[11]  L. Brewster,et al.  Anatomic characteristics of aortic transection: centerline analysis to facilitate graft selection. , 2014, Annals of vascular surgery.

[12]  V. Aboyans,et al.  [2014 ESC Guidelines on the diagnosis and treatment of aortic diseases]. , 2014, Kardiologia polska.

[13]  H. Rousseau,et al.  Endovascular Repair of Type B Aortic Dissection: Long-term Results of the Randomized Investigation of Stent Grafts in Aortic Dissection Trial , 2013, Circulation. Cardiovascular interventions.

[14]  R. Erbel,et al.  Recent advances in the diagnosis of acute aortic syndromes. , 2012, Expert opinion on medical diagnostics.

[15]  R. S. Mitchell,et al.  Endovascular repair of traumatic thoracic aortic injury: clinical practice guidelines of the Society for Vascular Surgery. , 2011, Journal of vascular surgery.

[16]  Joss D Fernandez,et al.  Endovascular Thoracic Aortic Aneurysm Repair: Evaluating the Utility of Intravascular Ultrasound Measurements , 2008, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[17]  G. Fraedrich,et al.  Serial CT Volume and Thrombus Length Measurements after Endovascular Repair of Stanford Type B Aortic Dissection , 2004, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[18]  Raimund Erbel,et al.  Effect of Medical and Surgical Therapy on Aortic Dissection Evaluated by Transesophageal Echocardiography Implications for Prognosis and Therapy , 1993, Circulation.