Acceleration of the direct reconstruction of linear parametric images using nested algorithms

Parametric imaging using dynamic positron emission tomography (PET) provides important information for biological research and clinical diagnosis. Indirect and direct methods have been developed for reconstructing linear parametric images from dynamic PET data. Indirect methods are relatively simple and easy to implement because the image reconstruction and kinetic modeling are performed in two separate steps. Direct methods estimate parametric images directly from raw PET data and are statistically more efficient. However, the convergence rate of direct algorithms can be slow due to the coupling between the reconstruction and kinetic modeling. Here we present two fast gradient-type algorithms for direct reconstruction of linear parametric images. The new algorithms decouple the reconstruction and linear parametric modeling at each iteration by employing the principle of optimization transfer. Convergence speed is accelerated by running more sub-iterations of linear parametric estimation because the computation cost of the linear parametric modeling is much less than that of the image reconstruction. Computer simulation studies demonstrated that the new algorithms converge much faster than the traditional expectation maximization (EM) and the preconditioned conjugate gradient algorithms for dynamic PET.

[1]  D. Brooks,et al.  Direct brain infusion of glial cell line–derived neurotrophic factor in Parkinson disease , 2003, Nature Medicine.

[2]  C. Comtat,et al.  Fully 4D image reconstruction by estimation of an input function and spectral coefficients , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  T. Jones,et al.  Spectral Analysis of Dynamic PET Studies , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[4]  Richard E. Carson,et al.  Comment: The EM Parametric Image Reconstruction Algorithm , 1985 .

[5]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[6]  R. Huesman,et al.  Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections , 2002 .

[7]  Habib Zaidi,et al.  Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction. , 2009, Medical physics.

[8]  Ken D. Sauer,et al.  Direct reconstruction of kinetic parameter images from dynamic PET data , 2005, IEEE Transactions on Medical Imaging.

[9]  C. Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. Generalizations , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  R. Huesman,et al.  Kinetic parameter estimation from attenuated SPECT projection measurements , 1997 .

[11]  Wan-Chi Siu,et al.  A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study , 1997, IEEE Transactions on Information Technology in Biomedicine.

[12]  I. Buvat,et al.  Iterative Kinetic Parameter Estimation within Fully 4D PET Image Reconstruction , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[13]  M. Phelps,et al.  Parametric images of myocardial metabolic rate of glucose generated from dynamic cardiac PET and 2-[18F]fluoro-2-deoxy-d-glucose studies. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Simon R. Cherry,et al.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images , 1994, IEEE Trans. Medical Imaging.

[15]  T. Jones,et al.  Parametric image reconstruction using spectral analysis of PET projection data. , 1998, Physics in medicine and biology.

[16]  D. Hunter,et al.  Optimization Transfer Using Surrogate Objective Functions , 2000 .

[17]  Andreas Robert Formiconi,et al.  Kinetic parameter estimation from renal measurements with a three-headed SPECT system: a Simulation study , 2004, IEEE Transactions on Medical Imaging.

[18]  Guobao Wang,et al.  Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data , 2009, IEEE Transactions on Medical Imaging.

[19]  D. Bailey,et al.  The direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction. , 1997 .

[20]  Kris Thielemans,et al.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography. , 2008, Medical physics.

[21]  R. Huesman,et al.  Direct least-squares estimation of spatiotemporal distributions from dynamic SPECT projections using a spatial segmentation and temporal B-splines , 2000, IEEE Transactions on Medical Imaging.

[22]  Linda Kaufman,et al.  Implementing and Accelerating the EM Algorithm for Positron Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[23]  Guobao Wang,et al.  MAXIMUM A POSTERIORI RECONSTRUCTION OF PATLAK PARAMETRIC IMAGE FROM SINOGRAMS IN DYNAMIC PET , 2008, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[24]  J. Bloch,et al.  Neurodegeneration prevented by lentiviral vector delivery of GDNF in primate models of Parkinson's disease. , 2000, Science.

[25]  M. Phelps,et al.  A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  Kenneth Lange,et al.  A Statistical Model for Positron Emission Tomography: Comment , 1985 .

[27]  Richard M. Leahy,et al.  Spatiotemporal reconstruction of list-mode PET data , 2002, IEEE Transactions on Medical Imaging.

[28]  Irène Buvat,et al.  Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM , 2006, Physics in medicine and biology.

[29]  C. Tsoumpas,et al.  Convergence properties of algorithms for direct parametric estimation of linear models in dynamic PET , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.