A new multi-modal similarity measure for fast gradient-based 2D-3D image registration

2D-3D image registration has been adopted in many clinical applications such as image-guided surgery and the kinematic analysis of bones in knee and ankle joints. In this paper we propose a new single-plane 2D-3D registration algorithm which requires far less iteration than previous techniques. The new algorithm includes a new multi-modal similarity measure and a novel technique for the analytic calculation of the required gradients. Our experimental results show that, when compared to existing gradient and non-gradient based techniques, the proposed algorithm has a wider range of initial poses for which registration can be achieved and requires significantly fewer iterations to converge to the true 3D position of the anatomical structure.

[1]  Laurent Sarry,et al.  Accurate and precise 2D-3D registration based on X-ray intensity , 2008, Comput. Vis. Image Underst..

[2]  Paul Suetens,et al.  Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information , 1999, Medical Image Anal..

[3]  Mark R. Pickering,et al.  Registration of multi-sensor remote sensing imagery by gradient-based optimization of cross-cumulative residual entropy , 2008, SPIE Defense + Commercial Sensing.

[4]  Nathan D. Cahill,et al.  Revisiting overlap invariance in medical image alignment , 2008, 2008 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops.

[5]  D. Dennis,et al.  In Vivo Fluoroscopic Analysis of the Normal Human Knee , 2003, Clinical orthopaedics and related research.

[6]  Max A. Viergever,et al.  Mutual-information-based registration of medical images: a survey , 2003, IEEE Transactions on Medical Imaging.

[7]  Baba C. Vemuri,et al.  Non-Rigid Multi-Modal Image Registration Using Cross-Cumulative Residual Entropy , 2007, International Journal of Computer Vision.

[8]  P. Abolmaesumi,et al.  2D/3D Registration of Multiple Bones , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  William E. Higgins,et al.  Real-time CT-video registration for continuous endoscopic guidance , 2006, SPIE Medical Imaging.

[10]  Michael Unser,et al.  Optimization of mutual information for multiresolution image registration , 2000, IEEE Trans. Image Process..

[11]  David A Jaffray,et al.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement. , 2008, Medical physics.