Root-end fracture during retropreparation: a comparison between zirconium nitride-coated and stainless steel microsurgical ultrasonic instruments.

The purpose of this study was to evaluate a stainless steel (CT-5) and zirconium nitride coated (KiS) microsurgical ultrasonic instrument with regard to possible root-end fracture production during retropreparation. Forty extracted human central incisors were prepared in a crown-down fashion. Canals were obturated with gutta-percha by lateral condensation. Root-ends were resected. Teeth were placed in methylene blue for 48 h and evaluated by three independent evaluators under microscope. Teeth with existing fractures were eliminated from the study. The remaining teeth were randomly divided into two equal groups. Group A was prepared with the CT-5 tip and Group B with the KiS tip. Preparation time was recorded for all roots. The teeth were again immersed in methylene blue for 48 h and reevaluated. No root-end fractures were produced by either the KiS or CT-5 microsurgical ultrasonic instruments.

[1]  B. Jeansonne,et al.  Effects of ultrasonic root-end preparation on microcrack formation and leakage. , 2000, Journal of endodontics.

[2]  J. Nicholls,et al.  Further investigation of spreader loads required to cause vertical root fracture during lateral condensation. , 1987, Journal of endodontics.

[3]  L. A. Morgan,et al.  Evaluation of diamond-coated ultrasonic instruments for root-end preparation. , 1999, Journal of endodontics.

[4]  H. Steiman,et al.  Preliminary investigation of ultrasonic root end preparation. , 1995, Journal of endodontics.

[5]  L. A. Morgan,et al.  The topography of root ends resected with fissure burs and refined with two types of finishing burs. , 1998, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[6]  J. Gutmann,et al.  Ultrasonic root-end preparation, Part 2. Microleakage of EBA root-end fillings. , 1994, International endodontic journal.

[7]  G. Carr Advanced techniques and visual enhancement for endodontic surgery. , 1992, The Endodontic report.

[8]  J. J. Legan,et al.  In vitro evaluation of effects of ultrasonic root-end preparation on resected root surfaces. , 1997, Journal of endodontics.

[9]  C. P. Lin,et al.  Root deformation during root-end preparation. , 1999, Journal of endodontics.

[10]  L. A. Morgan,et al.  Evaluation for cracks associated with ultrasonic root-end preparation of gutta-percha filled canals. , 1997, Journal of endodontics.

[11]  Stephen Cohen,et al.  Pathways of the Pulp , 1976 .

[12]  M. Torabinejad,et al.  A comparison between two root end preparation techniques in human cadavers. , 1994, Journal of endodontics.

[13]  L. A. Morgan,et al.  Evaluation of cracks associated with ultrasonic root-end preparation. , 1995, Journal of endodontics.

[14]  G Sundqvist,et al.  Factors affecting the long-term results of endodontic treatment. , 1990, Journal of endodontics.

[15]  F. Marshall,et al.  Methylene blue dye: an aid to endodontic surgery. , 1985, Journal of endodontics.

[16]  J. Baumgartner,et al.  Comparison of ultrasonic and high-speed-bur root-end preparations using bilaterally matched teeth. , 1997, Journal of endodontics.