Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation.

BACKGROUND It is thought that only a thin layer of tissue adjacent to the electrode is heated directly by electrical current (resistive heating) during radiofrequency ablation. Most of the thermal injury is thought to result from conduction of heat from the surface layer. The purpose of this study was to determine whether lesion depth could be increased by producing direct resistive heating deeper in the tissue with higher radiofrequency power, allowed by cooling the ablation electrode with saline irrigation to prevent the rise in impedance that occurs when the electrode-tissue interface temperature reaches 100 degrees C. METHODS AND RESULTS In 11 anesthetized dogs, the thigh muscle was exposed and bathed with heparinized canine blood (36 degrees C to 37 degrees C). A 7F catheter, with a central lumen, a 5-mm tip electrode with six irrigation holes, and an internal thermistor, was positioned perpendicular to the thigh muscle and held at a constant contact weight of 10 g. Radiofrequency current was delivered to 145 sites (1) at high constant voltage (66 V) without irrigation (CV group, n = 31), (2) at variable voltage (20 to 66 V) to maintain tip-electrode temperature at 80 degrees C to 90 degrees C without irrigation (temperature-control group, n = 39), and (3) at high CV (66 V) with saline irrigation through the catheter lumen and ablation electrode at 20 mL/min (CV irrigation group, n = 75). Radiofrequency current was applied for 60 seconds but was terminated immediately in the event of an impedance rise > or = 10 omega. Tip-electrode temperature and tissue temperature at depths of 3.5 and 7.0 mm were measured in all three groups (n = 145). In 33 CV irrigation group applications, temperature was also measured with a separate probe at the center (n = 18) or edge (n = 15) of the electrode-tissue interface. In all 31 CV group applications, radiofrequency energy delivery was terminated prematurely (at 11.6 +/- 4.8 seconds) owing to an impedance rise associated with an electrode temperature of 98.8 +/- 2.1 degrees C. All 39 temperature-control applications were delivered for 60 seconds without an impedance rise, but voltage had to be reduced to 38.4 +/- 6.1 V to avoid temperatures > 90 degrees C (mean tip-electrode temperature, 84.5 +/- 1.4 degrees C). In CV irrigation applications, the tip-electrode temperature was not > 48 degrees C (mean, 38.4 +/- 5.1 degrees C) and the electrode-tissue interface temperature was not > 80 degrees C (mean, 69.4 +/- 5.7 degrees C). An abrupt impedance rise with an audible pop and without coagulum occurred in 6 of 75 CV irrigation group applications at 30 to 51 seconds, probably owing to release of steam from below the surface. In the CV and temperature-control group applications, the temperatures at depths of 3.5 (62.1 +/- 15.1 degrees C and 67.9 +/- 7.5 degrees C) and 7.0 mm (40.3 +/- 5.3 degrees C and 48.3 +/- 4.8 degrees C) were always lower than the electrode temperature. Conversely, in CV irrigation group applications, electrode and electrode-tissue interface temperatures were consistently exceeded by the tissue temperature at depths of 3.5 mm (94.7 +/- 9.1 degrees C) and occasionally 7.0 mm (65.1 +/- 9.7 degrees C). Lesion dimensions were smallest in CV group applications (depth, 4.7 +/- 0.6 mm; maximal diameter, 9.8 +/- 0.8 mm; volume, 135 +/- 33 mm3), intermediate in temperature-control group applications (depth, 6.1 +/- 0.5 mm; maximal diameter, 11.3 +/- 0.9 mm; volume, 275 +/- 55 mm3), and largest in CV irrigation group applications (depth, 9.9 +/- 1.1 mm; maximal diameter, 14.3 +/- 1.5 mm; volume, 700 +/- 217 mm3; P < .01, respectively). CONCLUSIONS Saline irrigation maintains a low electrode-tissue interface temperature during radiofrequency application at high power, which prevents an impedance rise and produces deeper and larger lesions. A higher temperature in the tissue (3.5 mm deep) than at the electrode-tissue interface indicates that direct resistive heating occurred deeper

[1]  H Calkins,et al.  Temperature monitoring during radiofrequency catheter ablation of accessory pathways. , 1992, Circulation.

[2]  Hue-Teh Shih,et al.  Radiofrequency Catheter Ablation of Ventricular Tachycardia in Patients Without Structural Heart Disease , 1992, Circulation.

[3]  J. Langberg,et al.  Diagnosis and cure of the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardias during a single electrophysiologic test. , 1991, The New England journal of medicine.

[4]  G. Breithardt,et al.  Coagulation of Ventricular Myocardium Using Radiofrequency Alternating Current: Bio‐Physical Aspects and Experimental Findings , 1989, Pacing and clinical electrophysiology : PACE.

[5]  K. Kuck,et al.  Radiofrequency current catheter ablation of accessory atrioventricular pathways , 1991, The Lancet.

[6]  Ralph Lazzara,et al.  Radiofrequency Catheter Ablation of Idiopathic Left Ventricular Tachycardia Guided by a Purkinje Potential , 1993, Circulation.

[7]  J. Langberg,et al.  Temperature‐Guided Radiofrequency Catheter Ablation With Very Large Distal Electrodes , 1993, Circulation.

[8]  M. Haissaguerre,et al.  Radiofrequency Catheter Ablation of Left Lateral Accessory Pathways Via the Coronary Sinus , 1992, Circulation.

[9]  G. Kay,et al.  Selective Radiofrequency Ablation of the Slow Pathway for the Treatment of Atrioventricular Nodal Reentrant Tachycardia: Evidence for Involvement of Perinodal Myocardium Within the Reentrant Circuit , 1992, Circulation.

[10]  J. Langberg,et al.  Radiofrequency Catheter Ablation of Ventricular Tachycardia in Patients With Coronary Artery Disease , 1993, Circulation.

[11]  J. Gallagher,et al.  Functional Role of the Epicardium in Postinfarction Ventricular Tachycardia: Observations Derived From Computerized Epicardial Activation Mapping, Entrainment, and Epicardial Laser Photoablation , 1991, Circulation.

[12]  E. Downar,et al.  Endocardial mapping of ventricular tachycardia in the intact human heart. II. Evidence for multiuse reentry in a functional sheet of surviving myocardium. , 1992, Journal of the American College of Cardiology.

[13]  L. Organ Electrophysiologic principles of radiofrequency lesion making. , 1976, Applied neurophysiology.

[14]  D. Haines,et al.  Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. , 1990, Circulation.

[15]  D. Haines,et al.  The Biophysics of Radiofrequency Catheter Ablation in the Heart: The Importance of Temperature Monitoring , 1993, Pacing and clinical electrophysiology : PACE.

[16]  J. Langberg,et al.  Catheter Ablation with Radiofrequency Energy: Biophysical Aspects and Clinical Applications , 1992 .

[17]  Michael D. Lesh,et al.  Catheter Modification of the Atrioventricular Junction With Radiofrequency Energy for Control of Atrioventricular Nodal Reentry Tachycardia , 1991, Circulation.

[18]  J. Ruskin,et al.  Treatment of ventricular tachycardia by transcatheter radiofrequency ablation in patients with ischemic heart disease. , 1994, Circulation.

[19]  A Shitzer,et al.  Controlled destruction and temperature distributions in biological tissues subjected to monoactive electrocoagulation. , 1980, Journal of biomechanical engineering.

[20]  J. Langberg,et al.  Radiofrequency Catheter Ablation: The Effect of Electrode Size on Lesion Volume In Vivo , 1990, Pacing and clinical electrophysiology : PACE.

[21]  R. Lazzara,et al.  Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current. , 1991, The New England journal of medicine.

[22]  K. Kuck,et al.  Successful Catheter Ablation of Human Ventricular Tachycardia with Radiofrequency Current Guided by an Endocardial Map of the Area of Slow Conduction , 1991, Pacing and clinical electrophysiology : PACE.

[23]  M. R. Spiegel Mathematical handbook of formulas and tables , 1968 .

[24]  A. Graham,et al.  Determinants of Impedance Rise During Catheter Ablation of Bovine Myocardium with Radiofrequency Energy , 1989, Pacing and clinical electrophysiology : PACE.

[25]  D D Watson,et al.  Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. , 1990, Circulation research.

[26]  R. Lazzara,et al.  Myocardial Regions of Slow Conduction Participating in the Reentrant Circuit of Multiple Ventricular Tachycardias: Report on Ten Patients , 1991 .

[27]  D D Watson,et al.  Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free Wall , 1989, Pacing and clinical electrophysiology : PACE.

[28]  R N Hauer,et al.  Control of radiofrequency lesion size by power regulation. , 1989, Circulation.

[29]  D. Krum,et al.  Selective Transcatheter Ablation of the Fast and Slow Pathways Using Radiofrequency Energy in Patients With Atrioventricular Nodal Reentrant Tachycardia , 1992, Circulation.

[30]  J. Langberg,et al.  Catheter Ablation of Canine Myocardium with Radiofrequency Energy , 1989, Pacing and clinical electrophysiology : PACE.

[31]  R. Lazzara,et al.  Treatment of supraventricular tachycardia due to atrioventricular nodal reentry by radiofrequency catheter ablation of slow-pathway conduction. , 1992, The New England journal of medicine.

[32]  J. Langberg,et al.  Curative percutaneous catheter ablation using radiofrequency energy for accessory pathways in all locations: results in 100 consecutive patients. , 1992, Journal of the American College of Cardiology.