The Accuracy of Ultrasound Volume Flow Measurements in the Complex Flow Setting of a Forearm Vascular Access

Purpose Maturation of an arterio-venous fistula (AVF) frequently fails, with low post-operative fistula flow as a prognostic marker for this event. As pulsed wave Doppler (PWD) is commonly used to assess volume flow, we studied the accuracy of this measurement in the setting of a radio-cephalic AVF. Methods As in-vivo validation of fistula flow measurements is cumbersome, we performed simulations, integrating computational fluid dynamics with an ultrasound (US) simulator. Flow in the arm was calculated, based on a patient-specific model of the arm vasculature pre and post AVF creation. Raw ultrasound signals were subsequently simulated, from which Doppler spectra were calculated in both a proximal and a distal location. Results The velocity component in the direction of the PWD-US beam (vPWD), in a centered, small, sample volume, can be captured accurately using PWD spectrum mean-tracking (maximum bias [mB] 8.1%). However, when deriving flow rate from these measurements, a high degree of inaccuracy occurs. First, the angle-correction of vPWD towards the velocity along the axis of the vessel is largely influenced by the radial velocity components in the complex flow field (mB=16.3%). Second, the largest error is introduced when transferring the centerline velocity to the cross-sectional mean velocity without any knowledge of the flow profile (mB=97.7%). Conclusions In the setting of a forearm AVF, flow estimates based on PWD are hampered by the complex flow patterns. Overall, flow estimation based on centerline measurement, analyzed by mean-tracking of the RF-spectral estimates, under the assumption of a parabolic flow profile, appeared to provide the most reasonable values.

[1]  R S Reneman,et al.  Spectral composition of Doppler signals. , 1991, Ultrasound in medicine & biology.

[2]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  T. How,et al.  Factors associated with early failure of arteriovenous fistulae for haemodialysis access. , 1996, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[4]  P. Hoskins,et al.  Accuracy of maximum velocity estimates made using Doppler ultrasound systems. , 1996, The British journal of radiology.

[5]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[6]  M. Fillinger,et al.  Longitudinal comparison of dialysis access methods: risk factors for failure. , 1997, Journal of vascular surgery.

[7]  P J Brands,et al.  Reduction of the Clutter Component in Doppler Ultrasound Signals Based on Singular Value Decomposition: A Simulation Study , 1997, Ultrasonic imaging.

[8]  W. McDicken,et al.  Doppler Ultrasound: Physics, Instrumentation and Signal Processing , 2000 .

[9]  M. Robbin,et al.  Increasing arteriovenous fistulas in hemodialysis patients: problems and solutions. , 2002, Kidney international.

[10]  J. Tordoir,et al.  European guidelines for vascular access: clinical algorithms on vascular access for haemodialysis. , 2003, EDTNA/ERCA journal.

[11]  F. M. van der Sande,et al.  Prospective evaluation of failure modes in autogenous radiocephalic wrist access for haemodialysis. , 2003, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[12]  Simona Gioberge,et al.  ESRD patients in 2004: global overview of patient numbers, treatment modalities and associated trends. , 2005, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[13]  Nils R Planken,et al.  The relation between vascular access flow and different types of vascular access with systemic hemodynamics in hemodialysis patients. , 2005, Artificial organs.

[14]  Wim Van Biesen,et al.  Chronic kidney disease: a European perspective. , 2005, Kidney international. Supplement.

[15]  J. Éthier,et al.  Clinical practice guidelines for vascular access. , 2006, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[16]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[17]  A. Falk Maintenance and salvage of arteriovenous fistulas. , 2006, Journal of vascular and interventional radiology : JVIR.

[18]  C. Wanner,et al.  EBPG on Vascular Access. , 2007, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[19]  David Shemesh,et al.  Blood flow volume changes in the maturing arteriovenous access for hemodialysis. , 2007, Ultrasound in medicine & biology.

[20]  H. Torp,et al.  Ultrasound simulation of complex flow velocity fields based on computational fluid dynamics , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  F. N. van de Vosse,et al.  Assessment of blood volume flow in slightly curved arteries from a single velocity profile. , 2009, Journal of biomechanics.

[22]  M. Meyer,et al.  Hepatic vascular flow measurements by phase contrast MRI and doppler echography: A comparative and reproducibility study , 2010, Journal of magnetic resonance imaging : JMRI.

[23]  Jan Vierendeels,et al.  A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate. , 2010, Medical physics.

[24]  Pascal Verdonck,et al.  Full-hexahedral structured meshing for image-based computational vascular modeling. , 2011, Medical engineering & physics.