Design and development of laser Doppler velocimetry based on DSP technique for blood flow measurement

A graphic user interface and real-time laser Doppler velocimeter (LDV) based on the digital signal processor (DSP) had been designed and developed. The hardware setup included the Michelson inteferrrometer optics, photo-detector, current to voltage converter, AC amplifer and filtering circuits, as well as a DSP module. The software system on the Dsp module was also developed to access data and to perform the moment weighting algorithms. In addition, the processed data was transmitted to the personal computer and advanced analysis could be achieved. The velocity measurement using developed LDV device was calibrated by a mirror mounted on a linear vibrator. The outcomes presented high linearity and good accuracy. In vitro experiment employing this LDV system was also carried out. The results showed that the developed LDV instrument offered a flexible tool to investigate the blood flow of microcirculation system.

[1]  R. Nossal,et al.  Model for laser Doppler measurements of blood flow in tissue. , 1981, Applied optics.

[2]  S R Arridge,et al.  The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysis. , 1992, Physics in medicine and biology.

[3]  T. Winsor,et al.  Clinical Application of Laser Doppler Flowmetry for Measurement of Cutaneous Circulation in Health and Disease , 1987, Angiology.

[4]  S. Dubovitsky,et al.  A laser Doppler instrument for in vivo measurements of blood flow in single renal arterioles , 1993, IEEE Transactions on Biomedical Engineering.

[5]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[6]  C E Riva,et al.  Compact laser Doppler choroidal flowmeter. , 1999, Journal of biomedical optics.

[7]  M. H. Koelink,et al.  Laser Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue. , 1995, Applied optics.

[8]  Luc Duteil,et al.  A Double Wavelength Laser Doppler System to Investigate Skin Microcirculation , 1985, IEEE Transactions on Biomedical Engineering.

[9]  R L Bowman,et al.  Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. , 1977, The American journal of physiology.

[10]  G Ward,et al.  A critical review of laser Doppler flowmetry. , 1990, Journal of medical engineering & technology.

[11]  M. Stern,et al.  In vivo evaluation of microcirculation by coherent light scattering , 1975, Nature.

[12]  M. H. Koelink,et al.  Laser Doppler blood flowmetry using two wavelengths: Monte Carlo simulations and measurements. , 1994, Applied optics.

[13]  H.J.C.M. Sterenborg,et al.  Skin optics , 1989, IEEE Transactions on Biomedical Engineering.