Rapid free chlorine decay in the presence of Cu(OH)2: chemistry and practical implications.

A rapid reaction between free chlorine and the cupric hydroxide [Cu(OH)2] solids commonly found on pipe walls in premise plumbing can convert free chlorine to chloride and rapidly age Cu(OH)2 to tenorite (CuO). This reaction has important practical implications for maintaining free chlorine residuals in premise plumbing, commissioning of new copper pipe systems, and maintaining low levels of copper in potable water. The reaction stoichiometry between chlorine and Cu(OH)2 is consistent with formation of CuO through a metastable Cu(III) intermediate, although definitive mechanistic understanding requires future research. Natural levels of silica in water (0-30 mg/L), orthophosphate, and higher pH interfere with the rate of this reaction.

[1]  Kyoung-Shin Choi,et al.  Conditions and Mechanism for the Anodic Deposition of Cupric Oxide Films in Slightly Acidic Aqueous Media , 2007 .

[2]  V Gidi,et al.  Gastrointestinal effects associated with soluble and insoluble copper in drinking water. , 2001, Environmental health perspectives.

[3]  Robert M. Clark,et al.  Modeling Chlorine Residuals in Drinking‐Water Distribution Systems , 1994 .

[4]  M. Edwards,et al.  Implications of aqueous silica sorption to iron hydroxide: mobilization of iron colloids and interference with sorption of arsenate and humic substances. , 2001, Environmental science & technology.

[5]  J. Maynard,et al.  Comprehensive Inorganic Chemistry. Volume 1 , 1954 .

[6]  M. Pourbaix Atlas of Electrochemical Equilibria in Aqueous Solutions , 1974 .

[7]  B. McDonald,et al.  Impact of Secondary Disinfectants on Copper Corrosion under Stagnation Conditions , 2007 .

[8]  J. Coombs,et al.  The corrosion of copper by chlorinated drinking waters , 1982 .

[9]  A. E. Greenberg,et al.  Standard methods for the examination of water and wastewater : supplement to the sixteenth edition , 1988 .

[10]  Pratim Biswas,et al.  A model for chlorine concentration decay in pipes , 1993 .

[11]  A. Fane,et al.  Direct coagulation pretreatment in nanofiltration of waters rich in organic matter and calcium , 2001 .

[12]  Richard W. Taylor,et al.  Kinetics and mechanisms of the copper-catalyzed decomposition of hypochlorite and hypobromite. Properties of a dimeric copper(III) hydroxide intermediate , 1977 .

[13]  A. Al-Jasser,et al.  Chlorine decay in drinking-water transmission and distribution systems: pipe service age effect. , 2007, Water research.

[14]  Hsiao-Wen Chen,et al.  Modeling silica sorption to iron hydroxide. , 2002, Environmental science & technology.

[15]  M. W. Lister DECOMPOSITION OF SODIUM HYPOCHLORITE: THE UNCATALYZED REACTION , 1956 .

[16]  A. Din,et al.  The behaviour of the copper electrode in alkaline solutions upon alternate anodic and cathodic polarization , 1964 .

[17]  M. Raupach,et al.  The reaction between monosilicic acid and aluminium hydroxide. I. Kinetics of adsorption of silicic acid by aluminium hydroxide , 1967 .

[18]  S. Reiber Copper Plumbing Surfaces: An Electrochemical Study , 1989 .

[19]  Marc Edwards,et al.  The role of pipe ageing in copper corrosion by-product release , 2001 .

[20]  K. Powers Aging and Copper Corrosion By-Product Release: Role of Common Anions, Impact of Silica and Chlorine, and Mitigating Release in New Pipe , 2000 .

[21]  M. V. Letelier,et al.  Aging of copper pipes by drinking water , 2001 .

[22]  M. Benjamin,et al.  Effect of silicon on the crystallization and adsorption properties of ferric oxides. , 1985, Environmental science & technology.

[23]  M. Edwards,et al.  Organic matter and copper corrosion by-product release: a mechanistic study , 2001 .

[24]  Gunther F. Craun,et al.  Waterborne disease Outbreaks Caused by Distribution System Deficiencies , 2001 .

[25]  W. Stumm,et al.  The interaction of anions and weak acids with the hydrous goethite (α-FeOOH) surface , 1981 .

[26]  Michael R. Schock,et al.  Effect of pH, DIC, Orthophosphate and Sulfate on Drinking Water Cuprosolvency , 1996 .

[27]  Jason Clark Rushing,et al.  Advancing the Understanding of Water Distribution System Corrosion: Effects of Chlorine and Aluminum on Copper Pitting, Temperature Gradients on Copper Corrosion, and Silica on Iron Release , 2002 .

[28]  Michael R. Schock,et al.  Alkalinity, pH, and copper corrosion by‐product release , 1996 .

[29]  Jae K. Park,et al.  Effect of chlorine on corrosion in Drinking Water Systems , 2003 .

[30]  M. Edwards,et al.  Role of Temperature and pH in Cu(OH)2 Solubility , 1999 .

[31]  B. Marshall Initiation, Propagation, and Mitigation of Aluminum and Chlorine Induced Pitting Corrosion , 2004 .

[32]  Marc Edwards,et al.  The blue water phenomenon , 2000 .

[33]  Marc Edwards,et al.  Copper in the Urban Water Cycle , 2000 .

[34]  P. Bremer,et al.  Biocorrosion of Copper in Potable Water , 2001 .

[35]  L. Kiene,et al.  Relative importance of the phenomena responsible for chlorine decay in drinking water distribution systems , 1998 .