Research on conducted EMI and vibration characteristics of PM BLDC motors with different stator structures

In this paper, four PM BLDC motors with a same rotor but different stator structures are investigated. Conducted EMI on DC bus of each motor is tested and analyzed. A method to predict the conducted EMI characteristics by analyzing the DC bus current in frequency domain is proposed. Moreover, vibration experiment results of the motors operating under no-load condition are compared. Possible electromagnetic sources that produce main vibrations of each motor are elaborated.

[1]  Nobuyoshi Mutoh,et al.  New methods to suppress EMI noises in motor drive systems , 2002, IEEE Trans. Ind. Electron..

[2]  Z. Zhu,et al.  Instantaneous magnetic field distribution in permanent magnet brushless DC motors. IV. Magnetic field on load , 1993 .

[3]  Thomas A. Lipo,et al.  Improvements in EMC performance of inverter-fed motor drives , 1995 .

[4]  C. Vollaire,et al.  Measurements and Simulation of Common Mode Conducted Noise Emissions in Adjustable-Speed AC Drive Systems , 2009, 2009 20th International Zurich Symposium on Electromagnetic Compatibility.

[5]  Chen Li-gen Influence of Airgap Field Distribution and Surface PM Magnetisation in Brushless DC Motors , 2006 .

[6]  T.W. Nehl,et al.  Towards EMI prediction of a PM motor drive for automotive applications , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[7]  M. T. Wright,et al.  Electromagnetic compatibility of variable speed drives , 1996 .

[8]  Li Ran,et al.  Conducted electromagnetic emissions in induction motor drive systems. II. Frequency domain models , 1998 .

[9]  Josep Balcells,et al.  New simplified method for the simulation of conducted EMI generated by switched power converters , 2003, IEEE Trans. Ind. Electron..

[10]  Z. Zhu,et al.  Instantaneous magnetic field distribution in brushless permanent magnet DC motors. I. Open-circuit field , 1993 .

[11]  Gyu-Hong Kang,et al.  Vibration reduction of IPM type BLDC motor using negative third harmonic elimination method of air-gap flux density , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[12]  S. G. Crumley,et al.  EMI characteristics of power electronics switching circuits , 1992 .

[13]  Hao Zhang,et al.  A novel control strategy for vibration reduction in the permanent magnet motor drive system with eccentric load , 2008, 2008 International Conference on Electrical Machines and Systems.

[14]  Kwang-Joon Kim,et al.  Characterization of noise and vibration sources in interior permanent-magnet brushless DC motors , 2004 .

[15]  D. Howe,et al.  Vibration of PM Brushless Machines Having a Fractional Number of Slots Per Pole , 2006, IEEE Transactions on Magnetics.

[16]  Z. Zhu,et al.  Instantaneous magnetic field distribution in brushless permanent magnet DC motors. III. Effect of stator slotting , 1993 .

[17]  Russel J. Kerkman,et al.  EMI emissions of modern PWM AC drives , 1999 .

[18]  Li Ran,et al.  Conducted electromagnetic emissions in induction motor drive systems. I. Time domain analysis and identification of dominant modes , 1998 .

[19]  Z. Zhu,et al.  Instantaneous magnetic field distribution in brushless permanent magnet DC motors. II. Armature-reaction field , 1993 .

[20]  Jaroslaw Luszcz,et al.  Motor cable influence on the converter fed AC motor drive conducted EMI emission , 2009, 2009 Compatibility and Power Electronics.

[21]  Renyuan Tang,et al.  Electromagnetic and mechanical characterizations of noise and vibration in permanent magnet synchronous machines , 2006, IEEE Transactions on Magnetics.

[22]  D. Howe,et al.  Steady-State Dynamic Performance of a Direct Torque Controlled PM Brushless DC Drive Accounting for the Influence of PWM and Cogging Torque , 1988 .