Diffusion tensor MRI of the human kidney

This study characterizes the diffusion anisotropy of the human kidney using a diffusion‐weighted, single‐shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medulla were found to be 0.22 ± 0.12 and 0.39 ± 0.11, respectively (N = 10), which emphasizes the need for rotationally invariant diffusion measurements for clinical applications. Additional limitations for clinical diffusion imaging on the kidney are the strong susceptibility variations within the abdomen that restrict the use of imaging techniques employing long echo trains, and the severe motion sensitivity that limits the available imaging time to one breath‐hold. To overcome these problems an isotropic, diffusion‐weighted, segmented EPI protocol that facilitates the acquisition of high‐resolution diffusion‐weighted images within a single breath‐hold was implemented. Using this method, the apparent diffusion coefficient (ADC) of the cortex and medulla were found to be 2.89 ± 0.28 · 10−9 m2/s and 2.18 ± 0.36 · 10−9 m2/s (N = 10). J. Magn. Reson. Imaging 2001;14:42–49. © 2001 Wiley‐Liss, Inc.

[1]  A. Aisen,et al.  Feasibility of MR Diffusion Studies in the Kidney , 1995, Journal of magnetic resonance imaging : JMRI.

[2]  P. Basser,et al.  A simplified method to measure the diffusion tensor from seven MR images , 1998, Magnetic resonance in medicine.

[3]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[4]  J. Pekar,et al.  Echo-planar imaging of intravoxel incoherent motion. , 1990, Radiology.

[5]  P. Basser Inferring microstructural features and the physiological state of tissues from diffusion‐weighted images , 1995, NMR in biomedicine.

[6]  I. Yamada,et al.  Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. , 1999, Radiology.

[7]  P. Basser,et al.  Statistical artifacts in diffusion tensor MRI (DT‐MRI) caused by background noise , 2000, Magnetic resonance in medicine.

[8]  P. Basser,et al.  MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.

[9]  Y. Yamashita,et al.  Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion‐weighted echo‐planar MR imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[10]  E. Akbudak,et al.  Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results , 1996, Magnetic resonance in medicine.

[11]  Kardiale Triggerung zur verbesserten abdominellen MR-Diffusionsbildgebung , 2000 .

[12]  T. Murakami,et al.  Diffusion-weighted single-shot echoplanar MR imaging for liver disease. , 1999, AJR. American journal of roentgenology.

[13]  P. Basser,et al.  Diffusion tensor MR imaging of the human brain. , 1996, Radiology.

[14]  A. Song,et al.  Optimized isotropic diffusion weighting , 1995, Magnetic resonance in medicine.

[15]  P van Gelderen,et al.  Water diffusion and acute stroke , 1994, Magnetic resonance in medicine.

[16]  Sinisa Pajevic,et al.  Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: Application to white matter fiber tract mapping in the human brain , 1999, Magnetic resonance in medicine.

[17]  P. Basser,et al.  Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. , 1996, Journal of magnetic resonance. Series B.

[18]  I. Ohashi,et al.  Anisotropic diffusion in kidney: Apparent diffusion coefficient measurements for clinical use , 2000, Journal of magnetic resonance imaging : JMRI.

[19]  P. Basser,et al.  Toward a quantitative assessment of diffusion anisotropy , 1996, Magnetic resonance in medicine.

[20]  P. V. van Zijl,et al.  Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan , 1995, Magnetic resonance in medicine.

[21]  William H. Press,et al.  Numerical recipes in C , 2002 .

[22]  R R Edelman,et al.  Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. , 1994, Radiology.