Doppler microembolic signals in children with prosthetic cardiac valves.

BACKGROUND AND PURPOSE The aim of this study was the evaluation of the prevalence and counts of Doppler microembolic signals (MES) in children with prosthetic cardiac valves and their comparison to those obtained in corresponding adult patients. PATIENTS AND METHODS Nine children and 43 adults with ATS valves implanted in the aortic position were monitored over both middle cerebral arteries with transcranial Doppler ultrasound. MES were identified on-line according to standard criteria. Heart rate and rhythm, valve type, size and duration, patients' height, International Normalized Ratio, and prevalence of neurological complications were obtained from all study participants. RESULTS MES prevalence and counts were significantly higher in children compared with adult patients (100% versus 25.5% and 58 [18.5 to 115.5] versus 55 [2 to 10.5], median, 95% CI, respectively). No corresponding differences in valve duration of valve implant were evident, but children has heart rates and were significantly smaller compared with adults. A positive correlation between patients' size, heart rate, and MES counts was noted. CONCLUSIONS MES counts in children with mechanical prosthetic valves are significantly higher compared with those in corresponding adults. We hypothesize that this is due to (1) the shorter distance between aortic valve and middle cerebral artery, since cavitation bubbles have a short life span and are bound to dissolve with time, and (2) the faster heart rate in children, resulting in a higher number of valve closures per minute.

[1]  M. Kaps,et al.  Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid. , 1997, Stroke.

[2]  J. Svennevig,et al.  Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve. , 1995, Stroke.

[3]  J. Cleland,et al.  St. Jude Medical prosthesis in children. , 1994, The Journal of thoracic and cardiovascular surgery.

[4]  N. Hwang,et al.  Occluder closing behavior: a key factor in mechanical heart valve cavitation. , 1994, The Journal of heart valve disease.

[5]  K. Lees,et al.  Prevalence and Characteristics of Intracranial Microemboli Signals in Patients With Different Types of Prosthetic Cardiac Valves , 1994, Stroke.

[6]  H. Schaff,et al.  Late results after Starr-Edwards valve replacement in children. , 1984, The Journal of thoracic and cardiovascular surgery.

[7]  R. Levy,et al.  Use of Hancock porcine xenografts in children and adolescents. , 1980, The American journal of cardiology.

[8]  W. Roberts,et al.  Late failure of porcine valve heterografts in children. , 1979, The Journal of thoracic and cardiovascular surgery.

[9]  L. Edmunds,et al.  Long-term Mitral Valve Replacement in Young Children , 1978, Circulation.

[10]  L. Rayleigh VIII. On the pressure developed in a liquid during the collapse of a spherical cavity , 1917 .

[11]  J. Noth,et al.  Transcranial Doppler "High Intensity Transient Signals" in the acute phase and long-term follow-up of mechanical heart valve implantation. , 1995, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[12]  M. Spencer,et al.  Detection of microemboli in patients with artificial heart valves using transcranial Doppler: preliminary observations. , 1993, The Journal of heart valve disease.