Bilateral step length estimation using a single inertial measurement unit attached to the pelvis

BackgroundThe estimation of the spatio-temporal gait parameters is of primary importance in both physical activity monitoring and clinical contexts. A method for estimating step length bilaterally, during level walking, using a single inertial measurement unit (IMU) attached to the pelvis is proposed. In contrast to previous studies, based either on a simplified representation of the human gait mechanics or on a general linear regressive model, the proposed method estimates the step length directly from the integration of the acceleration along the direction of progression.MethodsThe IMU was placed at pelvis level fixed to the subject's belt on the right side. The method was validated using measurements from a stereo-photogrammetric system as a gold standard on nine subjects walking ten laps along a closed loop track of about 25 m, varying their speed. For each loop, only the IMU data recorded in a 4 m long portion of the track included in the calibrated volume of the SP system, were used for the analysis. The method takes advantage of the cyclic nature of gait and it requires an accurate determination of the foot contact instances. A combination of a Kalman filter and of an optimally filtered direct and reverse integration applied to the IMU signals formed a single novel method (Kalman and Optimally filtered Step length Estimation - KOSE method). A correction of the IMU displacement due to the pelvic rotation occurring in gait was implemented to estimate the step length and the traversed distance.ResultsThe step length was estimated for all subjects with less than 3% error. Traversed distance was assessed with less than 2% error.ConclusionsThe proposed method provided estimates of step length and traversed distance more accurate than any other method applied to measurements obtained from a single IMU that can be found in the literature. In healthy subjects, it is reasonable to expect that, errors in traversed distance estimation during daily monitoring activity would be of the same order of magnitude of those presented.

[1]  Andy Ruina,et al.  Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions , 2005, Exercise and sport sciences reviews.

[2]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[3]  A. Cereatti,et al.  Detection of Heel Strikes and Toe-Offs During Gait Using a Single Inertial Measurement Unit Attached to the Waist , 2010 .

[4]  D. Alvarez,et al.  Modified Pendulum Model for Mean Step Length Estimation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Hervé Carfantan,et al.  Time-invariant orthonormal wavelet representations , 1996, IEEE Trans. Signal Process..

[6]  Aurelio Cappozzo,et al.  An optimized Kalman filter for the estimate of trunk orientation from inertial sensors data during treadmill walking. , 2012, Gait & posture.

[7]  Mounir Zok,et al.  Total body centre of mass displacement estimated using ground reactions during transitory motor tasks: application to step ascent. , 2004, Medical engineering & physics.

[8]  M. Munneke,et al.  Measuring physical activity in patients after surgery for a malignant tumour in the leg. The reliability and validity of a continuous ambulatory activity monitor. , 2001, The Journal of bone and joint surgery. British volume.

[9]  John A. Crowe,et al.  Numerical double integration of acceleration measurements in noise , 2004 .

[10]  Richard R Neptune,et al.  Step length asymmetry is representative of compensatory mechanisms used in post-stroke hemiparetic walking. , 2011, Gait & posture.

[11]  Jukka Saarinen,et al.  MEMS-IMU Based Pedestrian Navigator for Handheld Devices , 2001 .

[12]  A. Cereatti,et al.  Estimation of stride length in level walking using an inertial measurement unit attached to the foot: a validation of the zero velocity assumption during stance. , 2011, Journal of biomechanics.

[13]  G. J. Kok,et al.  Measuring physical activity in patients after surgery for a malignant tumour in the leg. The reliability and validity of a continuous ambulatory activity monitor. , 2001 .

[14]  P H Veltink,et al.  Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implantable drop-foot stimulator. , 2003, Medical engineering & physics.

[15]  Marina M Schoemaker,et al.  Capacity, capability, and performance: different constructs or three of a kind? , 2009, Archives of physical medicine and rehabilitation.

[16]  H. Dawes,et al.  Assessment of spatio-temporal gait parameters using inertial measurement units in neurological populations. , 2011, Gait & posture.

[17]  S. Overeem,et al.  Walking patterns in Parkinson's disease with and without freezing of gait , 2011, Neuroscience.

[18]  W. H. Baird An introduction to inertial navigation , 2009 .

[19]  R N Marshall,et al.  Algorithms to determine event timing during normal walking using kinematic data. , 2000, Journal of biomechanics.

[20]  Angelo M. Sabatini,et al.  Assessment of walking features from foot inertial sensing , 2005, IEEE Transactions on Biomedical Engineering.

[21]  G. Cavagna,et al.  The sources of external work in level walking and running. , 1976, The Journal of physiology.

[22]  Zoran Djurić Mechanisms of noise sources in microelectromechanical systems , 2000 .

[23]  Eric Foxlin,et al.  Pedestrian tracking with shoe-mounted inertial sensors , 2005, IEEE Computer Graphics and Applications.

[24]  Marco Donati,et al.  Optimization of the Kalman filter parameters for the estimate of trunk angles from inertial sensors data during walking at different speeds , 2011 .

[25]  Peter H. Veltink,et al.  Ambulatory Assessment of Ankle and Foot Dynamics , 2007, IEEE Transactions on Biomedical Engineering.

[26]  S. Simon Gait Analysis, Normal and Pathological Function. , 1993 .

[27]  Jorunn L Helbostad,et al.  Estimation of gait cycle characteristics by trunk accelerometry. , 2004, Journal of biomechanics.

[28]  Chan Gook Park,et al.  Adaptive step length estimation algorithm using optimal parameters and movement status awareness. , 2011, Medical engineering & physics.

[29]  Xiaoping Yun,et al.  Self-contained Position Tracking of Human Movement Using Small Inertial/Magnetic Sensor Modules , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.