Regions of active damping control for LCL filters

The control of a grid connected voltage source inverter (VSI) with an LCL filter is a very challenging task, since the LCL network causes a resonance phenomenon near to the control stability boundary. While many active damping methods have been proposed to overcome this issue, the role that PWM transport delay plays in the effectiveness of these strategies is still not fully resolved. This paper presents a theoretical discrete time analysis frame work that identifies three distinct regions of LCL filter resonance - a high resonant frequency region where active damping isn't required; a critical resonant frequency where a controller cannot stabilise the system; and a low resonant frequency region where active damping is essential. Suitable controllers are then proposed for the two stable regions, with gain calculations that allow for the greatest system bandwidth and damping. Simulation and experimental results verify the presented analysis.

[1]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[2]  M. Liserre,et al.  A stable three-phase LCL-filter based active rectifier without damping , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[3]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[4]  Poh Chiang Loh,et al.  Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[5]  Naim A. Kheir,et al.  Control system design , 2001, Autom..

[6]  Steffan Hansen,et al.  Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.

[7]  Xinbo Ruan,et al.  A full-feedforward scheme of grid voltages for a three-phase grid-connected inverter with an LCL filter , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[8]  M. Liserre,et al.  Stability improvements of an LCL-filter based three-phase active rectifier , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[9]  M. Liserre,et al.  Characterization of differential-mode filter for grid-side converters , 2009, 2009 35th Annual Conference of IEEE Industrial Electronics.

[10]  Xing Zhang,et al.  A novel control strategy of LCL-VSC based on notch concept , 2010, The 2nd International Symposium on Power Electronics for Distributed Generation Systems.

[11]  Friedrich W. Fuchs,et al.  Models and effects of different updating and sampling concepts to the control of grid-connected PWM converters — A study based on discrete time domain analysis , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[12]  Dehong Xu,et al.  A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter , 2010, IEEE Transactions on Industrial Electronics.

[13]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[14]  Paolo Mattavelli,et al.  Digital Control in Power Electronics , 2006, Digital Control in Power Electronics.

[15]  Yi Lei,et al.  An improved virtual resistance damping method for grid-connected inverters with LCL filters , 2011, 2011 IEEE Energy Conversion Congress and Exposition.