Characterizing the Mechanical Properties of Running-Specific Prostheses

The mechanical stiffness of running-specific prostheses likely affects the functional abilities of athletes with leg amputations. However, each prosthetic manufacturer recommends prostheses based on subjective stiffness categories rather than performance based metrics. The actual mechanical stiffness values of running-specific prostheses (i.e. kN/m) are unknown. Consequently, we sought to characterize and disseminate the stiffness values of running-specific prostheses so that researchers, clinicians, and athletes can objectively evaluate prosthetic function. We characterized the stiffness values of 55 running-specific prostheses across various models, stiffness categories, and heights using forces and angles representative of those measured from athletes with transtibial amputations during running. Characterizing prosthetic force-displacement profiles with a 2nd degree polynomial explained 4.4% more of the variance than a linear function (p<0.001). The prosthetic stiffness values of manufacturer recommended stiffness categories varied between prosthetic models (p<0.001). Also, prosthetic stiffness was 10% to 39% less at angles typical of running 3 m/s and 6 m/s (10°-25°) compared to neutral (0°) (p<0.001). Furthermore, prosthetic stiffness was inversely related to height in J-shaped (p<0.001), but not C-shaped, prostheses. Running-specific prostheses should be tested under the demands of the respective activity in order to derive relevant characterizations of stiffness and function. In all, our results indicate that when athletes with leg amputations alter prosthetic model, height, and/or sagittal plane alignment, their prosthetic stiffness profiles also change; therefore variations in comfort, performance, etc. may be indirectly due to altered stiffness.

[1]  C. T. Farley,et al.  Leg stiffness and stride frequency in human running. , 1996, Journal of biomechanics.

[3]  Matthew W Bundle,et al.  The fastest runner on artificial legs: different limbs, similar function? , 2009, Journal of applied physiology.

[4]  Hiroaki Hobara,et al.  Amputee locomotion: spring-like leg behavior and stiffness regulation using running-specific prostheses. , 2013, Journal of biomechanics.

[5]  Heikki Kyröläinen,et al.  A simple method for measuring stiffness during running. , 2005, Journal of applied biomechanics.

[6]  Hugh M Herr,et al.  Running-specific prostheses limit ground-force during sprinting , 2010, Biology Letters.

[7]  A. Arampatzis,et al.  The effect of speed on leg stiffness and joint kinetics in human running. , 1999, Journal of biomechanics.

[8]  R. M. Alexander Energy-saving mechanisms in walking and running. , 1991, The Journal of experimental biology.

[9]  Alena M. Grabowski,et al.  Effects of velocity and weight support on ground reaction forces and metabolic power during running. , 2008, Journal of applied biomechanics.

[10]  R. Kram,et al.  Mechanics of running under simulated low gravity. , 1991, Journal of applied physiology.

[11]  Walter D. Pilkey Analysis and design of elastic beams , 2002 .

[12]  R Kram,et al.  Applied horizontal force increases impact loading in reduced-gravity running. , 2001, Journal of biomechanics.

[13]  Claire T. Farley,et al.  Energetically optimal stride frequency in running: the effects of incline and decline , 2011, Journal of Experimental Biology.

[14]  Christopher J. Arellano,et al.  The effects of step width and arm swing on energetic cost and lateral balance during running. , 2011, Journal of biomechanics.

[15]  Alena M. Grabowski,et al.  Effect of Running Speed and Leg Prostheses on Mediolateral Foot Placement and Its Variability , 2015, PloS one.

[16]  Hugh M Herr,et al.  Leg stiffness of sprinters using running-specific prostheses , 2012, Journal of The Royal Society Interface.

[17]  P. Komi,et al.  Knee and ankle joint stiffness in sprint running. , 2002, Medicine and science in sports and exercise.

[18]  G. Cavagna,et al.  MECHANICAL WORK IN RUNNING. , 1964, Journal of applied physiology.

[19]  R. Blickhan The spring-mass model for running and hopping. , 1989, Journal of biomechanics.

[20]  K. R. Williams,et al.  The effect of stride length variation on oxygen uptake during distance running. , 1982, Medicine and science in sports and exercise.

[21]  C. T. Farley,et al.  Running springs: speed and animal size. , 1993, The Journal of experimental biology.

[22]  Adamantios Arampatzis,et al.  Biomechanics of double transtibial amputee sprinting using dedicated sprinting prostheses , 2008 .

[23]  Alexander Rm,et al.  Energy-saving mechanisms in walking and running. , 1991 .

[24]  Lee Nolan,et al.  Carbon fibre prostheses and running in amputees: a review. , 2008, Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons.

[25]  J. Shim,et al.  Amputee locomotion: determining the inertial properties of running-specific prostheses. , 2013, Archives of physical medicine and rehabilitation.

[26]  T. McMahon,et al.  The mechanics of running: how does stiffness couple with speed? , 1990, Journal of biomechanics.

[27]  J. Czerniecki,et al.  Joint moment and muscle power output characteristics of below knee amputees during running: the influence of energy storing prosthetic feet. , 1991, Journal of biomechanics.

[28]  Siamak Noroozi,et al.  An Investigation Into the Measurement and Prediction of Mechanical Stiffness of Lower Limb Prostheses Used for Running , 2014, Assistive technology : the official journal of RESNA.