Respiratory activity extracted from wrist-worn reflective photoplethysmography in a sleep-disordered population

Objective: Respiratory activity is an essential parameter to monitor healthy and disordered sleep, and unobtrusive measurement methods have important clinical applications in diagnostics of sleep-related breathing disorders. We propose a respiratory activity surrogate extracted from wrist-worn reflective photoplethysmography validated on a heterogeneous dataset of 389 sleep recordings. Approach: The surrogate was extracted by interpolating the amplitude of the PPG pulses after evaluation of pulse morphological quality. Subsequent multistep post-processing was applied to remove parts of the surrogate with low quality and high motion levels. In addition to standard respiration rate performance, we evaluated the similarity between surrogate respiratory activity and reference inductance plethysmography of the thorax, using Spearman’s correlations and spectral coherence, and assessed the influence of PPG signal quality, motion levels, sleep stages and obstructive sleep apnea. Main results: Prior to post-processing, the surrogate already had a strong similarity with the reference (correlation = 0.54, coherence = 0.81), and reached respiration rate estimation performance in line with the literature (estimation error = 0.76± 2.11 breaths/min). Detrimental effects of low PPG quality, high motion levels and sleep-dependent physiological phenomena were significantly mitigated by the proposed post-processing steps (correlation = 0.62, coherence = 0.88, estimation error = 0.53± 1.85 breaths/min). Significance: Wrist-worn PPG can be used to extract respiratory activity, thus allowing respiration monitoring in real-world sleep medicine applications using (consumer) wearable devices.

[1]  Ruud J. G. van Sloun,et al.  Protocol of the SOMNIA project: an observational study to create a neurophysiological database for advanced clinical sleep monitoring , 2019, BMJ Open.

[2]  Gabriele B. Papini,et al.  Estimation of the apnea-hypopnea index in a heterogeneous sleep-disordered population using optimised cardiovascular features , 2019, Scientific Reports.

[3]  Dingchang Zheng,et al.  Toward Accurate Extraction of Respiratory Frequency From the Photoplethysmogram: Effect of Measurement Site , 2019, Front. Physiol..

[4]  Nadi Sadr,et al.  A comparison of three ECG-derived respiration methods for sleep apnoea detection , 2019, Biomedical Physics & Engineering Express.

[5]  Qichen Li,et al.  Deep learning in the cross-time frequency domain for sleep staging from a single-lead electrocardiogram , 2018, Physiological measurement.

[6]  Sebastiaan Overeem,et al.  Sinus or not: a new beat detection algorithm based on a pulse morphology quality index to extract normal sinus rhythm beats from wrist-worn photoplethysmography recordings , 2018, Physiological measurement.

[7]  Po-Lei Lee,et al.  A Method for Respiration Rate Detection in Wrist PPG Signal Using Holo-Hilbert Spectrum , 2018, IEEE Sensors Journal.

[8]  Linda M. Eerikäinen,et al.  Comparison between electrocardiogram- and photoplethysmogram-derived features for atrial fibrillation detection in free-living conditions , 2018, Physiological measurement.

[9]  Cinna Soltanpur,et al.  A review on wearable photoplethysmography sensors and their potential future applications in health care , 2018, International journal of biosensors & bioelectronics.

[10]  Tapio Taipalus,et al.  Comparison of photoplethysmogram measured from wrist and finger and the effect of measurement location on pulse arrival time , 2018, Physiological measurement.

[11]  G. Dumont,et al.  Extracting Instantaneous Respiratory Rate From Multiple Photoplethysmogram Respiratory-Induced Variations , 2018, Front. Physiol..

[12]  J. Pépin,et al.  Sleep biology updates: Hemodynamic and autonomic control in sleep disorders. , 2018, Metabolism: clinical and experimental.

[13]  Ronald M. Aarts,et al.  Estimating blood pressure trends and the nocturnal dip from photoplethysmography , 2018, Physiological measurement.

[14]  T. Penzel,et al.  New technology to assess sleep apnea: wearables, smartphones, and accessories , 2018, F1000Research.

[15]  Matt T Bianchi,et al.  Sleep devices: wearables and nearables, informational and interventional, consumer and clinical. , 2017, Metabolism: clinical and experimental.

[16]  Ronald M. Aarts,et al.  Validation of Photoplethysmography-Based Sleep Staging Compared With Polysomnography in Healthy Middle-Aged Adults , 2017, Sleep.

[17]  Sebastiaan Overeem,et al.  Photoplethysmography beat detection and pulse morphology quality assessment for signal reliability estimation , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[18]  Paul S Addison,et al.  Respiratory effort from the photoplethysmogram. , 2017, Medical engineering & physics.

[19]  K. Patrick,et al.  The Boom in Wearable Technology: Cause for Alarm or Just What is Needed to Better Understand Sleep? , 2016, Sleep.

[20]  Vivek Jain,et al.  Respiratory rate variability in sleeping adults without obstructive sleep apnea , 2016, Physiological reports.

[21]  Carmen C. Y. Poon,et al.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension , 2016, Journal of Medical Systems.

[22]  L. Tarassenko,et al.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram , 2016, Physiological measurement.

[23]  Sebastiaan Overeem,et al.  Assessment of respiratory effort during sleep: Esophageal pressure versus noninvasive monitoring techniques. , 2015, Sleep medicine reviews.

[24]  Paul S. Addison,et al.  Respiratory modulations in the photoplethysmogram (DPOP) as a measure of respiratory effort , 2015, Journal of Clinical Monitoring and Computing.

[25]  Xi Long,et al.  Sleep stage classification with ECG and respiratory effort , 2015, Physiological measurement.

[26]  David A. Clifton,et al.  Signal-Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless Monitoring , 2015, IEEE Journal of Biomedical and Health Informatics.

[27]  Sabine Van Huffel,et al.  A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG , 2015, IEEE Transactions on Biomedical Engineering.

[28]  P. Kyriacou,et al.  The effect of vascular changes on the photoplethysmographic signal at different hand elevations , 2015, Physiological measurement.

[29]  Xi Long,et al.  Analyzing respiratory effort amplitude for automated sleep stage classification , 2014, Biomed. Signal Process. Control..

[30]  Xi Long,et al.  Sleep and Wake Classification With Actigraphy and Respiratory Effort Using Dynamic Warping , 2014, IEEE Journal of Biomedical and Health Informatics.

[31]  M. Westover,et al.  Automated Sleep Apnea Quantification Based on Respiratory Movement , 2014, International journal of medical sciences.

[32]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[33]  Lino Nobili,et al.  Heart rate variability in normal and pathological sleep , 2013, Front. Physiol..

[34]  M. Palaniswami,et al.  Investigating Relative Respiratory Effort Signals During Mixed Sleep Apnea Using Photoplethysmogram , 2013, Annals of Biomedical Engineering.

[35]  L. Nilsson Respiration Signals from Photoplethysmography , 2013, Anesthesia and analgesia.

[36]  Walter Karlen,et al.  Multiparameter Respiratory Rate Estimation From the Photoplethysmogram , 2013, IEEE Transactions on Biomedical Engineering.

[37]  Jesús Lázaro,et al.  Deriving respiration from photoplethysmographic pulse width , 2013, Medical & Biological Engineering & Computing.

[38]  Sabine Van Huffel,et al.  Application of Kernel Principal Component Analysis for Single-Lead-ECG-Derived Respiration , 2012, IEEE Transactions on Biomedical Engineering.

[39]  Toshiyo Tamura,et al.  The Advantages of Wearable Green Reflected Photoplethysmography , 2011, Journal of Medical Systems.

[40]  D. Sebastiano,et al.  Periodic limb movements both in non-REM and REM sleep: Relationships between cerebral and autonomic activities , 2009, Clinical Neurophysiology.

[41]  Eduardo Gil,et al.  Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of PPG Signal in Children by HRV Analysis , 2009, IEEE Transactions on Biomedical Engineering.

[42]  H. Asada,et al.  Utility of the Photoplethysmogram in Circulatory Monitoring , 2008, Anesthesiology.

[43]  H. Cabral,et al.  Multiple Comparisons Procedures , 2008, Circulation.

[44]  K. Shelley Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate , 2007, Anesthesia and analgesia.

[45]  H. Barnhart,et al.  An Overview on Assessing Agreement with Continuous Measurements , 2007, Journal of biopharmaceutical statistics.

[46]  Jay W Mason,et al.  Electrocardiographic reference ranges derived from 79,743 ambulatory subjects. , 2007, Journal of electrocardiology.

[47]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[48]  Gordon R. Williams,et al.  Pulse transit time changes observed with different limb positions , 2005, Physiological measurement.

[49]  Fiorenza Giganti,et al.  Body movements during night sleep in healthy elderly subjects and their relationships with sleep stages , 2004, Brain Research Bulletin.

[50]  R. Thomas,et al.  Arousals in sleep-disordered breathing: patterns and implications. , 2003, Sleep.

[51]  Thomas Penzel,et al.  Comparison of detrended fluctuation analysis and spectral analysis for heart rate variability in sleep and sleep apnea , 2003, IEEE Transactions on Biomedical Engineering.

[52]  E. Katz,et al.  Pulse Transit Time as a Measure of Arousal and Respiratory Effort in Children with Sleep-Disordered Breathing , 2003, Pediatric Research.

[53]  A. Murray,et al.  Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques , 1999, Physiological measurement.

[54]  J. Ringler,et al.  Hemodynamic consequences of obstructive sleep apnea. , 1996, Sleep.

[55]  F. Abboud,et al.  Sympathetic-nerve activity during sleep in normal subjects. , 1993, The New England journal of medicine.

[56]  M. Kryger,et al.  Principles And Practice Of Sleep Medicine , 1989 .

[57]  H. Schulz,et al.  Rate and Distribution of Body Movements during Sleep in Humans , 1983, Perceptual and motor skills.

[58]  K. Strohl,et al.  Effect of intrathoracic pressure on left-ventricular performance. , 1980, The New England journal of medicine.

[59]  A. Buda,et al.  Effect of intrathoracic pressure on left ventricular performance. , 1979, The New England journal of medicine.

[60]  S. Shapiro,et al.  An Analysis of Variance Test for Normality (Complete Samples) , 1965 .

[61]  W. Kruskal,et al.  Use of Ranks in One-Criterion Variance Analysis , 1952 .

[62]  H. B. Mann,et al.  On a Test of Whether one of Two Random Variables is Stochastically Larger than the Other , 1947 .

[63]  Boreom Lee,et al.  Energy-Efficient Photoplethysmogram Compression to Estimate Heart and Respiratory Rates Simultaneously , 2019, IEEE Access.

[64]  J. Calvert,et al.  Chapter 6 – Overview of Cardiac Muscle Physiology , 2012 .

[65]  KR Westerterp,et al.  Advances in physical activity monitoring and lifestyle interventions in obesity: a review , 2012, International Journal of Obesity.

[66]  M. Carskadon,et al.  Chapter 2 - Normal Human Sleep : An Overview , 2005 .

[67]  Hurst Jw,et al.  Respiratory Rate and Pattern -- Clinical Methods: The History, Physical, and Laboratory Examinations , 1990 .