Motion-resilient Heart Rate Monitoring with In-ear Microphones

With the soaring adoption of in-ear wearables, the research community has started investigating suitable in-ear Heart Rate (HR) detection systems. HR is a key physiologicalmarker of cardiovascular health and physical fitness. Continuous and reliable HR monitoring with wearable devices has therefore gained increasing attention in recent years. Existing HR detection systems in wearables mainly rely on Photoplethysmography (PPG) sensors, however these are notorious for poor performance in the presence of human motion. In this work, leveraging the sound enhancing properties of the occlusion effect, which can be generated by sealing the entrance of the ear canal (something that some existing earphones already do to improve noise cancellation), we investigate for the first time in-ear audio-based motion-resilient HR monitoring. This is done by measuring HR-induced sound in the human ear canal with in-ear microphones. Concretely, we develop a novel motion artefact (MA) removal technique based on wavelet transforms, followed by an HR estimation algorithm to extract HR from in-ear audio signals compounded with other activities (e.g., walking, running, and speaking). Unlike existing works, we present a systematic evaluation of our technique under a set of different motion artifacts and while speaking.With data collected from 15 subjects over four activities, we demonstrate that our approach achieves a mean absolute error (MAE) of 0.88±0.27 BPM, 8.11±3.89 BPM, 13.79±5.61 BPM and 7.49±3.23 BPM for stationary, walking, running and speaking, respectively, opening the door to a new non-invasive and affordable HR monitoring with usable performance for daily activities. Conference’17, July 2017, Washington, DC, USA 2021. ACM ISBN 978-x-xxxx-xxxx-x/YY/MM. . . $15.00 https://doi.org/10.1145/nnnnnnn.nnnnnnn

[1]  Jérémie Voix,et al.  In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring , 2018, IEEE Transactions on Biomedical Engineering.

[2]  Sang Hyuk Son,et al.  On-Device Filter Design for Self-Identifying Inaccurate Heart Rate Readings on Wrist-Worn PPG Sensors , 2020, IEEE Access.

[3]  Feng Liu,et al.  Research and Implementation of Heart Sound Denoising , 2012 .

[4]  Paul van Gent,et al.  Analysing Noisy Driver Physiology Real-Time Using Off-the-Shelf Sensors: Heart Rate Analysis Software from the Taking the Fast Lane Project , 2019, Journal of Open Research Software.

[5]  Thad Starner,et al.  Stick it in your ear: building an in-ear jaw movement sensor , 2015, UbiComp/ISWC Adjunct.

[6]  Jérémie Voix,et al.  The Journal of the Acoustical Society of America SpEAR: An in-ear speech database in varying conditions of the audio-phonation loop , 2018 .

[7]  George R. Wodicka,et al.  Detection of respiratory sounds at the external ear , 2004, IEEE Transactions on Biomedical Engineering.

[8]  J. Tonndorf A new concept of bone conduction. , 1968, Archives of otolaryngology.

[9]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[10]  Syed Anas Imtiaz,et al.  Algorithm for heart rate extraction in a novel wearable acoustic sensor , 2015, Healthcare technology letters.

[11]  P. Klimach,et al.  An in-ear pulse wave velocity measurement system using heart sounds as time reference , 2020, 2008.02064.

[12]  Farrokh Marvasti,et al.  Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry , 2015, IEEE Signal Processing Letters.

[13]  Sung Gyoo Park Medicine and Science in Sports and Exercise , 1981 .

[14]  Cecilia Mascolo,et al.  OESense: employing occlusion effect for in-ear human sensing , 2021, MobiSys.

[15]  Zheng Zhang,et al.  Denoising method of heart sound signals based on self-construct heart sound wavelet , 2014 .

[16]  Atsushi Nishikawa,et al.  Earable TEMPO: A Novel, Hands-Free Input Device that Uses the Movement of the Tongue Measured with a Wearable Ear Sensor , 2018, Sensors.

[17]  Cecilia Mascolo,et al.  Enabling In-Ear Magnetic Sensing: Automatic and User Transparent Magnetometer Calibration , 2021, 2021 IEEE International Conference on Pervasive Computing and Communications (PerCom).

[18]  Yang Wang,et al.  Heart rate monitoring from wrist-type PPG based on singular spectrum analysis with motion decision , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[19]  Andriy Temko,et al.  Accurate Heart Rate Monitoring During Physical Exercises Using PPG , 2017, IEEE Transactions on Biomedical Engineering.

[20]  Buntarou Shizuki,et al.  CanalSense: Face-Related Movement Recognition System based on Sensing Air Pressure in Ear Canals , 2017, UIST.

[21]  Jacob W. Manning,et al.  Concurrent heart rate validity of wearable technology devices during trail running , 2020, PloS one.

[22]  S. S. Rathod,et al.  VLSI Wavelet Based Denoising of PPG Signal , 2015 .

[23]  Bodo Urban,et al.  EarFieldSensing: A Novel In-Ear Electric Field Sensing to Enrich Wearable Gesture Input through Facial Expressions , 2017, CHI.

[24]  Changseok Bae,et al.  Adaptive Noise Cancellation Using Accelerometers for the PPG Signal from Forehead , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Paul Lukowicz,et al.  Analysis of Chewing Sounds for Dietary Monitoring , 2005, UbiComp.

[26]  El-Sayed A. El-Dahshan,et al.  Denoising of Heart Sound Signals Using Discrete Wavelet Transform , 2017, Circuits Syst. Signal Process..

[27]  Haneen Farah,et al.  Heart Rate Analysis for Human Factors: Development and Validation of an Open Source Toolkit for Noisy Naturalistic Heart Rate Data , 2018 .

[28]  W. Kibbe,et al.  Investigating sources of inaccuracy in wearable optical heart rate sensors , 2020, npj Digital Medicine.

[29]  Veit Senner,et al.  In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography? , 2019, Sensors.

[30]  Matthias Budde,et al.  Towards Respiration Rate Monitoring Using an In-Ear Headphone Inertial Measurement Unit , 2019, EarComp@UbiComp.

[31]  George Tzanetakis,et al.  A comparison between audio and IMU data to detect chewing events based on an earable device , 2020, AH.

[32]  Taeho Kim,et al.  eBP: A Wearable System For Frequent and Comfortable Blood Pressure Monitoring From User's Ear , 2019, MobiCom.

[33]  M. Usman Akram,et al.  Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review , 2021, EURASIP J. Adv. Signal Process..

[34]  B. Moore,et al.  A Technique for Estimating the Occlusion Effect for Frequencies Below 125 Hz , 2014, Ear and hearing.

[35]  Chulhong Min,et al.  Earables for Personal-Scale Behavior Analytics , 2018, IEEE Pervasive Computing.

[36]  Zhilin Zhang,et al.  Combining ensemble empirical mode decomposition with spectrum subtraction technique for heart rate monitoring using wrist-type photoplethysmography , 2015, Biomed. Signal Process. Control..

[37]  Chris Van Hoof,et al.  Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths , 2019, Sensors.

[38]  G. Giorgi,et al.  Robust estimation and tracking of heart rate by PPG signal analysis , 2017, 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[39]  E. Hari Krishna,et al.  Evaluation of wavelets for reduction of motion artifacts in photoplethysmographic signals , 2010, 10th International Conference on Information Science, Signal Processing and their Applications (ISSPA 2010).

[40]  Murray Mp,et al.  Treadmill vs. floor walking: kinematics, electromyogram, and heart rate. , 1985, Journal of applied physiology.

[41]  Guang-Zhong Yang,et al.  A Flexible, Low Noise Reflective PPG Sensor Platform for Ear-Worn Heart Rate Monitoring , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[42]  D. Giavarina Understanding Bland Altman analysis , 2015, Biochemia medica.

[43]  Christos Papavassiliou,et al.  Hearables: Multimodal physiological in-ear sensing , 2016, Scientific Reports.

[44]  Guoxing Wang,et al.  Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering , 2019, Sensors.

[45]  Geevarghese Titus,et al.  Photoplethysmogram (PPG) signal analysis and wavelet de-noising , 2014, 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA/iCMMD).

[46]  Aaron O'Leary,et al.  PyWavelets: A Python package for wavelet analysis , 2019, J. Open Source Softw..

[47]  Andriy Temko,et al.  Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[48]  T. Fu,et al.  Heart Rate Extraction from Photoplethysmogram Waveform Using Wavelet Multi-resolution Analysis , 2008 .

[49]  Yuan-Ting Zhang,et al.  Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter , 2002, Proceedings of IEEE Sensors.

[50]  Dwaipayan Biswas,et al.  Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review , 2019, IEEE Sensors Journal.

[51]  Kamal Jafarian,et al.  Color spectrographic respiratory monitoring from the external ear canal. , 2018, Clinical science.