Post-calibration compensation method for integral imaging system with macrolens array.

Three-dimensional display with large-format is an inevitable and foreseeable trend for the future display technology, integral imaging is one of the most powerful and promising candidates to achieve this goal with full-parallax, true-color, acceptable viewing resolution and viewing angle. To obtain a 3D display with high quality, calibration is needed to correct optical misalignment and optical aberrations, which is often challenging and time consuming. We propose a post-calibration compensation method for the integral imaging system with macrolens array, the inter-lens position misalignment is corrected by forcing it to image in a regular ideal reference grid. Our method distinguishes itself from previous ones by finding the correct pixel-to-ray correspondence with a relatively simple setup and acceptable precision. A prototype is fabricated to evaluate the feasibility of the proposed method. Furthermore, the proposed method is evaluated in terms of the geometrical accuracy and quality of the reconstructed images.

[1]  Chongxiu Yu,et al.  Wavefront aberration correction for integral imaging with the pre-filtering function array. , 2018, Optics express.

[2]  Masahiro Yamaguchi,et al.  Full-Parallax Holographic Light-Field 3-D Displays and Interactive 3-D Touch , 2017, Proceedings of the IEEE.

[3]  Faliu Yi,et al.  Three-dimensional integral imaging by using unknown sensor array position calibration with a closed-form solution , 2016 .

[4]  Bahram Javidi,et al.  Fundamentals of 3D imaging and displays: a tutorial on integral imaging, light-field, and plenoptic systems , 2018 .

[5]  Xingpeng Yan,et al.  Integral imaging based light field display with enhanced viewing resolution using holographic diffuser , 2017 .

[6]  X. Sang,et al.  Aberration improvement of the floating 3D display system based on Tessar array and directional diffuser screen , 2018, Optical Review.

[7]  Byoungho Lee Three-dimensional displays, past and present , 2013 .

[8]  Hongen Liao,et al.  Hybrid camera array based calibration for computer-generated integral photography display. , 2018, Journal of the Optical Society of America. A, Optics, image science, and vision.

[9]  Yongtian Wang,et al.  A Review of Dynamic Holographic Three-Dimensional Display: Algorithms, Devices, and Systems , 2016, IEEE Transactions on Industrial Informatics.

[10]  M. Kawakita,et al.  Geometric analysis of spatial distortion in projection-type integral imaging. , 2008, Optics letters.

[11]  Ichiro Sakuma,et al.  Real-time computer-generated integral imaging and 3D image calibration for augmented reality surgical navigation , 2015, Comput. Medical Imaging Graph..

[12]  Youfu Li,et al.  Generic camera model and its calibration for computational integral imaging and 3D reconstruction. , 2011, Journal of The Optical Society of America A-optics Image Science and Vision.

[13]  Liangcai Cao,et al.  Three-dimensional display technologies in wave and ray optics: a review (Invited Paper) , 2014 .

[14]  Wenhua Dou,et al.  Demonstration of a large-size real-time full-color three-dimensional display. , 2009, Optics letters.

[15]  Shujun Xing,et al.  Interactive floating full-parallax digital three-dimensional light-field display based on wavefront recomposing. , 2018, Optics express.

[16]  Xing Mei,et al.  Principal Observation Ray Calibration for Tiled-Lens-Array Integral Imaging Display , 2013, 2013 IEEE Conference on Computer Vision and Pattern Recognition.

[17]  F. Okano,et al.  Geometrical effects of positional errors in integral photography. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  Xingpeng Yan,et al.  Nonlinear mapping method for the generation of an elemental image array in a photorealistic pseudoscopic free 3D display. , 2018, Applied optics.

[19]  Huan Deng,et al.  Tilted elemental image array generation method for moiré-reduced computer generated integral imaging display. , 2013, Optics express.

[20]  A. Aggoun Pre-Processing of Integral Images for 3-D Displays , 2006, Journal of Display Technology.

[21]  Hongen Liao,et al.  Accurate 3D autostereoscopic display using optimized parameters through quantitative calibration. , 2017, Journal of the Optical Society of America. A, Optics, image science, and vision.