Ex vivo determination of bone tissue strains for an in vivo mouse tibial loading model

Previous studies introduced the digital image correlation (DIC) as a viable technique for measuring bone strain during loading. In this study, we investigated the sensitivity of a DIC system in determining surface strains in a mouse tibia while loaded in compression through the knee joint. Specifically, we examined the effect of speckle distribution, facet size and overlap, initial vertical alignment of the bone into the loading cups, rotation with respect to cameras, and ex vivo loading configurations on the strain contour maps measured with a DIC system. We loaded tibiae of C57BL/6 mice (12 and 18 weeks old male) up to 12 N at 8 N/min. Images of speckles on the bone surface were recorded at 1 N intervals and DIC was used to compute strains. Results showed that speckles must have the correct size and density with respect to the facet size of choice for the strain distribution to be computed and reproducible. Initial alignment of the bone within the loading cups does not influence the strain distribution measured during peak loading, but bones must be placed in front of the camera with the same orientation in order for strains to be comparable. Finally, the ex vivo loading configurations with the tibia attached to the entire mouse, or to the femur and foot, or only to the foot, showed different strain contour maps. This work provides a better understanding of parameters affecting full field strain measurements from DIC in ex vivo murine tibial loading tests.

[1]  Felix Eckstein,et al.  Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: a new model to study cortical and cancellous compartments in a single loaded element. , 2005, Bone.

[2]  R. Zernicke,et al.  Strain Gradients Correlate with Sites of Exercise‐Induced Bone‐Forming Surfaces in the Adult Skeleton , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[3]  Sven Bossuyt,et al.  Quality assessment of speckle patterns for digital image correlation , 2006 .

[4]  C. Rubin,et al.  Strain Gradients Correlate with Sites of Periosteal Bone Formation , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[5]  R. Huiskes,et al.  A three-dimensional digital image correlation technique for strain measurements in microstructures. , 2004, Journal of biomechanics.

[6]  Ronald F Zernicke,et al.  Strain rate influences periosteal adaptation in mature bone. , 2005, Medical engineering & physics.

[7]  Daniel P Nicolella,et al.  Measurement of microstructural strain in cortical bone. , 2005, European journal of morphology.

[8]  L E Lanyon,et al.  Strain magnitude related changes in whole bone architecture in growing rats. , 1997, Bone.

[9]  A. Pitsillides,et al.  Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia. , 2010, Journal of biomechanics.

[10]  A Staines,et al.  Bone adaptation to load: microdamage as a stimulus for bone remodelling , 2002, Journal of anatomy.

[11]  L. Lanyon,et al.  Regulation of bone formation by applied dynamic loads. , 1984, The Journal of bone and joint surgery. American volume.

[12]  D. Davy,et al.  Machine vision photogrammetry: a technique for measurement of microstructural strain in cortical bone. , 2001, Journal of biomechanics.

[13]  L. Lanyon,et al.  Growth rate rather than gender determines the size of the adaptive response of the growing skeleton to mechanical strain. , 2002, Bone.

[14]  M P Akhter,et al.  Bone-loading response varies with strain magnitude and cycle number. , 2001, Journal of applied physiology.

[15]  M. Bennett,et al.  Modification of the in vivo four-point loading model for studying mechanically induced bone adaptation. , 1998, Bone.

[16]  H. Haddadi,et al.  Use of rigid-body motion for the investigation and estimation of the measurement errors related to digital image correlation technique , 2008 .

[17]  D Aubry,et al.  Effect of microstructure on the mechanical properties of Haversian cortical bone. , 2006, Bone.

[18]  M. Jergas,et al.  Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques , 2005, Osteoporosis International.

[19]  N Ohashi,et al.  Modulation of appositional and longitudinal bone growth in the rat ulna by applied static and dynamic force. , 2001, Bone.

[20]  L E Lanyon,et al.  Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats. , 1998, Bone.

[21]  Sheng Liu,et al.  Measurement of Strain Distributions in Mouse Femora with 3D-Digital Speckle Pattern Interferometry. , 2007, Optics and lasers in engineering.

[22]  Hirakazu Kasuya,et al.  Measurement of Cortical Bone Strain Distribution by Image Correlation Techniques and from Fracture Toughness , 2011 .