Accuracy Enhancement of Doppler Radar-Based Heartbeat Rate Detection Using Chest-Wall Acceleration

The theoretical and experimental study of a new noncontact heartbeat signal processing technique using a continuous-wave 2.4-GHz Doppler radar is presented in this paper. This system can detect the human heartbeat rate at 1m away from the human body. Experimental results confirm the validity of the proposed approach. The recorded data from ten healthy human subjects show an average heartbeat rate detection accuracy of more than 95% when compared with reference electrocardiogram (ECG) recordings. A theoretical analysis is also provided to support the proposed method and demonstrate that by exploiting the second derivative of the received signal which corresponds to the chest wall acceleration, the detection rate can be significantly increased. The proposed technique is robust and simple, and measurement results indicate its potential for being used for the development of reliable non-contact heartbeat rate monitoring systems.

[1]  Hirofumi Taki,et al.  Feature-Based Correlation and Topological Similarity for Interbeat Interval Estimation Using Ultrawideband Radar , 2016, IEEE Transactions on Biomedical Engineering.

[2]  Wei Hu,et al.  Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor , 2014, IEEE Transactions on Biomedical Engineering.

[3]  Chenxi Yang,et al.  Utilizing Gyroscopes Towards the Automatic Annotation of Seismocardiograms , 2017, IEEE Sensors Journal.

[4]  Changzhi Li,et al.  1-D Microwave Imaging of Human Cardiac Motion: An Ab-Initio Investigation , 2013, IEEE Transactions on Microwave Theory and Techniques.

[5]  O. Boric-Lubecke,et al.  Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar , 2009, IEEE Transactions on Microwave Theory and Techniques.

[6]  Changzhi Li,et al.  A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[7]  Negar Tavassolian,et al.  Effects of Antenna Characteristics on the Performance of Heart Rate Monitoring Radar Systems , 2017, IEEE Transactions on Antennas and Propagation.

[8]  Changzhi Li,et al.  A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems , 2017, IEEE Transactions on Microwave Theory and Techniques.

[9]  Negar Tavassolian,et al.  High-Accuracy Heart Rate Variability Monitoring Using Doppler Radar Based on Gaussian Pulse Train Modeling and FTPR Algorithm , 2018, IEEE Transactions on Microwave Theory and Techniques.