Study of Harmonic Distortion Propagation from a Wind Park

Wind parks are electrical generation arrangements with non-linear characteristics. In fact, these complexes are potential sources of harmonic current injection upon the electric power systems, since their operation is fundamentally dependent on power electronic-based devices. Given this reality, for the connection of new installations, access studies must be carried out by the proponent according to the regulatory agency guidelines. In Brazil, these guidelines are given by the National Electric-System Operator according to a set of documents and instructions that support the requested studies. In this context, this paper is aimed at evaluating the influences of the PCC transformer representation and also the levels of background imbalance on the harmonic distortion propagation from a wind park. These influences are evaluated in the context of Brazilian regulatory standards by means of a typical national equivalent grid. In summary, the results suggest that the network representation may influence harmonic propagation.

[1]  L. Moura Avaliação experimental do desempenho de unidades eólicas quanto à geração de distorções harmônicas , 2017 .

[2]  N.W. Miller,et al.  Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[3]  Liangzhong Yao,et al.  A wind park emitting characteristic and non-characteristic harmonics , 2010, Proceedings of 14th International Power Electronics and Motion Control Conference EPE-PEMC 2010.

[4]  R. Gagnon,et al.  Large-Scale Real-Time Simulation of Wind Power Plants into Hydro-Québec Power System , 2010 .

[5]  I. N. Santos,et al.  Performance Evaluation of Harmonic Current Summation Law Applying to the Wind and Photovoltaic Generation , 2016, IEEE Latin America Transactions.

[6]  Alessandro Goedtel,et al.  Analysis of Noncharacteristic Harmonics Generated by Voltage-Source Converters Operating Under Unbalanced Voltage , 2017, IEEE Transactions on Power Delivery.

[7]  Francisco Canales,et al.  Integrated DC ‑ AC Converter as Power Conditioner for Fuel Cell Based System , 2016, IEEE Latin America Transactions.

[8]  Liangzhong Yao,et al.  Harmonic and interharmonic distortion due to a windpark , 2010, IEEE PES General Meeting.

[9]  Jose Mateus Rondina,et al.  Technology Alternative for Enabling Distributed Generation , 2016, IEEE Latin America Transactions.

[10]  Dehong Xu,et al.  Advanced Control of Doubly Fed Induction Generator for Wind Power Systems , 2018 .

[11]  M. Grotzbach,et al.  Noncharacteristic line current harmonics in diode rectifier bridges produced by network asymmetries , 2002 .

[12]  Alex Reis,et al.  Experimental Evaluation of Wind Turbines Inverters on Generating Harmonic Currents , 2019 .

[13]  M. Liserre,et al.  Power Electronics Converters for Wind Turbine Systems , 2012, IEEE Transactions on Industry Applications.

[14]  Zifa Liu,et al.  Harmonic Assessment for Wind Parks Based on Sensitivity Analysis , 2017, IEEE Transactions on Sustainable Energy.

[16]  Luiz Carlos Gomes de Freitas,et al.  Harmonic Distortion Analysis in a Low Voltage Grid-Connected Photovoltaic System , 2015, IEEE Latin America Transactions.

[17]  Marco Liserre,et al.  Overview of Multi-MW Wind Turbines and Wind Parks , 2011, IEEE Transactions on Industrial Electronics.