Exergy analysis of an experimental heat transformer for water purification

First and second law of thermodynamics have been used to analyze the performance of an experimental heat transformer used for water purification. The pure water is produced in the auxiliary condenser delivering an amount of heat, which is recycled into the heat transformer increasing the heat source temperatures and also the internal, external and exergy coefficients of performance. The theoretical and experimental study was divided into two parts. In the first part, a second law analysis was carried out to the experimental system showing that the absorber and the condenser are the components with the highest irreversibilities. In the second part, with the results obtained from the second law analysis, new test runs were carried out at similar conditions than the former but varying only one selected temperature at the time. Comparing the COP (coefficient of performance) between the old and new test runs, it was shown that higher internal, external and exergy coefficients of performance were obtained in all the new test runs. Also it was shown that the ECOP (exergy coefficient of performance) increases with an increment of the amount of the purified water produced and with the decrease of the flow ratio.

[1]  Jiabin Chen,et al.  Application of absorption heat transformer to recover waste heat from a synthetic rubber plant , 2003 .

[2]  Editörden A Comparison Between Ammonia-Water and Water-Lithium Bromide Solutions in Absorption Heat Transformers , 2004 .

[3]  Å. Jernqvist,et al.  Experimental and theoretical study of an open multi-compartment absorption heat transformer for different steam temperatures. Part III: application to process industry , 1999 .

[4]  S. A. Fartaj,et al.  Comparison of energy, exergy, and entropy balance methods for analysing double‐stage absorption heat transformer cycles , 2004 .

[5]  Andrea Costa,et al.  Integration of absorption heat pumps in a Kraft pulp process for enhanced energy efficiency , 2009 .

[6]  Wilfrido Rivera,et al.  Energy and exergy analysis of a double absorption heat transformer operating with water/lithium bromide , 2009 .

[7]  Y. Kaita,et al.  Thermodynamic properties of lithium bromide-water solutions at high temperatures. , 2001 .

[8]  Hugh W. Coleman,et al.  Experimentation, Validation, and Uncertainty Analysis for Engineers , 2009 .

[9]  Adnan Sözen,et al.  Effect of irreversibilities on performance of an absorption heat transformer used to increase solar pond¿s temperature , 2004 .

[10]  Masaru Ishida,et al.  Graphical exergy study on single stage absorption heat transformer , 1999 .

[11]  Rosenberg J. Romero,et al.  Portable water purification system integrated to a heat transformer , 2004 .

[12]  F. A. Holland Water Purification Using Heat Pumps , 1999 .

[13]  A. Vidal,et al.  Analysis of a combined power and refrigeration cycle by the exergy method , 2006 .

[14]  Abdolreza Zaltash,et al.  Refractive indexes of aqueous LiBr solutions , 1992 .

[15]  Georgios A. Florides,et al.  Design and construction of a LiBr–water absorption machine , 2003 .

[16]  Wilfrido Rivera,et al.  Exergetic and exergoeconomic optimization of a cogeneration pulp and paper mill plant including the use of a heat transformer , 2010 .

[17]  P. E. Liley,et al.  Steam and Gas Tables with Computer Equations , 1984 .

[18]  Rosenberg J. Romero,et al.  Increase of COP for heat transformer in water purification systems. Part I – Increasing heat source temperature , 2007 .

[19]  Adnan Sözen,et al.  Exergy analysis of an ejector-absorption heat transformer using artificial neural network approach , 2007 .

[20]  S. A. Sherif,et al.  Second law analysis of multi-stage lithium bromide/water absorption heat transformers , 2000 .