Screen-printed reference electrodes for potentiometric measurements

A convenient and reliable method for large-scale production of miniaturized, planar, all-solid-state reference electrodes is reported. All elements of the Ag/AgCl/KCl reference half-cell i.e. layer of Ag/AgCl (inner electrode), immobilized electrolyte (junction) and encapsulation are fabricated by means of screen-printing technology. The use of pastes cured in low temperature allows fabrication on low-cost, plastic, flexible foils. The developed reference electrodes exhibit good long-term stability. Continuous operation life-time exceeds one week. Storage stability is longer than 9 months. pH, chlorides as well as other halide anions, typical buffer components, alkaline and heavy metal cations, complexing ligands and redox agents, do not influence the potential of the reference electrodes. The developed reference electrodes are compatible with strip potentiometric sensors fabricated in the same format. Examples of analytical applications of the reference electrodes with various screen-printed sensors are demonstrated.

[1]  Isao Karube,et al.  Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor , 1999 .

[2]  R. Koncki,et al.  POTENTIOMETRIC THICK-FILM GRAPHITE ELECTRODES WITH IMPROVED RESPONSE TO COPPER IONS , 2001 .

[3]  A. Mroz Disposable reference electrode , 1998 .

[4]  C. Fang,et al.  Screen-printable sol–gel ceramic carbon composite pH sensor with a receptor zeolite , 2002 .

[5]  John Atkinson,et al.  Planar thick-film pH electrodes based on ruthenium dioxide hydrate , 1998 .

[6]  Jae Ho Shin,et al.  Solvent-Processible Polymer Membrane-Based Liquid Junction-Free Reference Electrode , 1998 .

[7]  Li Qingwen,et al.  Response of nanosized cobalt oxide electrodes as pH sensors , 2000 .

[8]  Mark E. Meyerhoff,et al.  New solvent system for the improved electrochemical performance of screen-printed polyurethane membrane-based solid-state sensors , 1996 .

[9]  Isao Karube,et al.  Micromachined liquid-junction Ag/AgCl reference electrode , 1998 .

[10]  R. Koncki,et al.  Screen-printed ruthenium dioxide electrodes for pH measurements , 1997 .

[11]  R. Koncki,et al.  Screen-printed copper ion-selective electrodes , 2000, Fresenius' journal of analytical chemistry.

[12]  R. Koncki,et al.  Strip thick-film silver ion-selective electrodes , 2003 .

[13]  Richard B. Brown,et al.  Screen printing: a technology for the batch fabrication of integrated chemical-sensor arrays , 1995 .

[14]  Timothy D. Strong,et al.  Solid-state ion sensors with a liquid junction-free polymer membrane-based reference electrode for blood analysis , 2000 .

[15]  Ilaria Palchetti,et al.  Disposable strip potentiometric electrodes with solvent-polymeric ion-selective membranes fabricated using screen-printing technology , 1999 .

[16]  Dermot Diamond,et al.  Evaluation of miniaturised solid state reference electrodes on a silicon based component , 1997 .