Experimental study on blind bolted connections to concrete-filled stainless steel columns

Abstract This paper studies the performance of blind bolted connections to concrete-filled stainless steel tubular columns. An experimental investigation was conducted on seven full-scale joints to study the effects of the following parameters: (a) presence of the floor slab or not; (b) with or without binding bars in the connection region; (c) type of steel used for the column (stainless or carbon steel); and (d) loading type (monotonic or cyclic). The experimental results demonstrated the good performance of the blind bolts in this type of connection. No bolt shank fracture was observed in any of the test specimens. The presence of the binding bars slightly enhanced the performance of the blind bolted connections, whereas the presence of composite slabs significantly affected the failure mode, initial stiffness, flexural resistance, and rotation capacity of the joints. Owing to the use of flush end plates, the joint without floor slab can be classified as nominally pinned joint according to EC3. But in the presence of the floor slab, the joint nearly reached its full strength and the stiffness was also significantly increased close to the limit for rigid sway frames. In addition, the test results indicated that the material type of the steel tube had no obvious influence on the joint performance. In contrast, the cyclic loading led to slightly decreased joint strength, but had more obvious detrimental influence on the joint stiffness.

[1]  Brian Uy,et al.  Hysteretic behaviour of flush end plate joints to concrete-filled steel tubular columns , 2009 .

[2]  B. Uy,et al.  Impact behaviour of pre-compressed hollow and concrete filled mild and stainless steel columns , 2014 .

[3]  Walid Tizani,et al.  Performance of T-stub to CFT joints using blind bolts with headed anchors , 2015 .

[4]  J. Lippold,et al.  Microstructure/property relationships in dissimilar welds between duplex stainless steels and carbon steels , 1998 .

[5]  J. Buick Davison,et al.  Strength and rotational response of moment connections to tubular columns using flowdrill connectors , 1999 .

[6]  Iman Hajirasouliha,et al.  Hysteretic performance of a new blind bolted connection to concrete filled columns under cyclic loading: An experimental investigation , 2013 .

[7]  Anne Gardner,et al.  Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns , 2006 .

[8]  Mark A. Bradford,et al.  Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors , 2015 .

[9]  Z. Tao,et al.  Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire , 2016 .

[10]  黒羽 啓明,et al.  Design guide for structural hollow section column connections , 2004 .

[11]  Brian Uy,et al.  The effects of partial shear connection in composite flush end plate joints Part I — experimental study , 2006 .

[12]  Leroy Gardner,et al.  Structural design of stainless steel concrete filled columns , 2008 .

[13]  B Uy,et al.  Behaviour of flush end plate joints to concrete-filled steel tubular columns , 2009 .

[14]  Mark A. Bradford,et al.  The effects of partial shear connection in the hogging moment regions of composite beams. Part 1: Experimental study , 2004 .

[15]  Brian Uy,et al.  Behaviour of composite beam-column flush end-plate connections subjected to low-probability, high-consequence loading , 2011 .

[16]  N. E. Shanmugam,et al.  Testing of steel-concrete composite connections and appraisal of results , 2000 .

[17]  Helen M. Goldsworthy,et al.  Blind bolted T-stub connections to unfilled hollow section columns in low rise structures , 2010 .

[18]  Yousef.M. Alostaz,et al.  Experimental Behavior of Connections to Concrete-filled Steel Tubes , 1998 .

[19]  Leroy Gardner,et al.  The use of stainless steel in structures , 2005 .

[20]  John S. Owen,et al.  Rotational stiffness of a blind-bolted connection to concrete-filled tubes using modified Hollo-bolt , 2013 .

[21]  Feng Fu,et al.  Experimental study on semi-rigid composite joints with steel beams and precast hollowcore slabs , 2006 .

[22]  Yong Wang,et al.  Experimental study of structural fire behaviour of steel beam to concrete filled tubular column assemblies with different types of joints , 2007 .

[23]  Lin-Hai Han,et al.  Cyclic behaviour of novel blind bolted joints with different stiffening elements , 2016 .

[24]  Ehab Ellobody,et al.  Design and behaviour of concrete-filled cold-formed stainless steel tube columns , 2006 .

[25]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .

[26]  Brian Uy,et al.  Behaviour of short and slender concrete-filled stainless steel tubular columns , 2011 .