Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation

Background/aims To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. Methods In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. Results In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6–29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r2=−0.42 (p<0.0001), r2=−0.5 (p<0.0001), r2=−0.34 (p=0.010), r2=−0.28 (p=0.049) and r2<0.001 (p=0.866), respectively, Conclusions ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae.

[1]  J. W. Lewis,et al.  A three‐part system for refining intraocular lens power calculations , 1988, Journal of cataract and refractive surgery.

[2]  G. Baïkoff Anterior segment OCT and phakic intraocular lenses: A perspective , 2006, Journal of cataract and refractive surgery.

[3]  C. Lindemann,et al.  Intraocular lens calculation for aspheric intraocular lenses , 2013, Journal of cataract and refractive surgery.

[4]  O. Findl,et al.  Ray tracing for intraocular lens calculation , 2002, Journal of cataract and refractive surgery.

[5]  R. Olson,et al.  Evaluation of variables affecting intraoperative aberrometry , 2012, Journal of cataract and refractive surgery.

[6]  T. Olsen,et al.  Prediction of the effective postoperative (intraocular lens) anterior chamber depth , 2006, Journal of cataract and refractive surgery.

[7]  Oliver Findl,et al.  Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements. , 2013, Investigative ophthalmology & visual science.

[8]  S. Mak,et al.  Clinical evaluation of the intraoperative refraction technique for intraocular lens power calculation. , 2010, Ophthalmology.

[9]  Sverker Norrby The Dubbelman eye model analysed by ray tracing through aspheric surfaces , 2005, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[10]  Howard V. Gimbel,et al.  Comparison of the SRK/T formula and other theoretical and regression formulas , 1990, Journal of cataract and refractive surgery.

[11]  B. Zuberbuhler,et al.  Errata in printed Hoffer Q formula. , 2007, Journal of cataract and refractive surgery.

[12]  K. Hoffer,et al.  The Hoffer Q formula: A comparison of theoretic and regression formulas , 1993, Journal of cataract and refractive surgery.

[13]  Mats Lundström,et al.  Evidence-based guidelines for cataract surgery: guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery database. , 2012, Journal of cataract and refractive surgery.

[14]  Donald R. Sanders,et al.  Development of the SRK/T intraocular lens implant power calculation formula , 1990, Journal of cataract and refractive surgery.

[15]  Sverker Norrby,et al.  Sources of error in intraocular lens power calculation , 2008, Journal of cataract and refractive surgery.

[16]  W. Haigis Occurrence of Erroneous Anterior Chamber Depth in the SRK/T Formula , 1993, Journal of cataract and refractive surgery.

[17]  Qinmei Wang,et al.  Repeatability, reproducibility, and agreement of central anterior chamber depth measurements in pseudophakic and phakic eyes: Optical coherence tomography versus ultrasound biomicroscopy , 2010, Journal of cataract and refractive surgery.

[18]  S. Norrby,et al.  Prediction of intraocular lens power using the lens haptic plane concept , 1997, Journal of cataract and refractive surgery.

[19]  J. Sparrow,et al.  Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry , 2011, Journal of cataract and refractive surgery.