In vitro testing of artificial heart valves: comparison between Newtonian and non-Newtonian fluids.

The in vitro testing of artificial heart valves is often performed with simple fluids like glycerol solutions. Blood, however, is a non-Newtonian fluid with a complex viscoelastic behavior, and different flow fields in comparable geometries may result. Therefore, we used different polymer solutions (Polyacrylamid, Xanthan gum) with blood-like rheological properties as well as various Newtonian fluids (water, glycerol solutions) in our heart valve test device. Hydrodynamic parameters of Björk-Shiley heart valves with a tissue annulus diameter (TAD) of 21-29 mm were investigated under aortic flow conditions. Major results can be summarized as follows. The mean systolic pressure differences depend on the model fluids tested. Closing time and closing volume are not influenced by the rheological behavior of fluids. These parameters depend on TAD and the pressure differences across the valve. In contrast, rheological behavior has a pronounced influence upon leakage flow and leakage volume, respectively. Results show furthermore that the apparent viscosity data as a function of shear rate are not sufficient to characterize the rheological fluid behavior relevant to hydrodynamic parameters of the heart valves investigated. Therefore, similarity in the yield curves of non-Newtonian test fluids mimicing blood is only a pre-requisite for a suitable test fluid. More information about the viscous and elastic component of the fluid viscosity is required, especially in geometries where a complex flow field exists as in the case of leakage flow.

[1]  K Schichl,et al.  [Testing the hydrodynamic properties of heart valve prostheses with a new test apparatus]. , 1994, Biomedizinische Technik. Biomedical engineering.

[2]  Nolan Sp The International Standard Cardiovascular implants--Cardiac Valve Prostheses (ISO 5840:1989) and the FDA Draft Replacement Heart Valve Guidance (Version 4.0) , 1994 .

[3]  K. Affeld,et al.  Viscoelastic behaviour of human blood and polyacrylamide model fluids for heart valve testing , 1993 .

[4]  M Pohl,et al.  Hydrodynamischer In-vitro-Vergleich einer neuen künstlichen Herzklappe mit der Björk-Shiley-Klappe (Standard) - Hydrodynamic In-vitro Comparison of a New Artificial Heart Valve with the Björk-Shiley Valve (Standard) , 1991, Biomedizinische Technik. Biomedical engineering.

[5]  D. Lerche,et al.  The Influence of Rheological Properties of Test Fluids on the Flow Pattern Inside the Artificial Ventricle (Type Rostock) and in the Aortic Outflow Tract , 1990 .

[6]  J. Tarbell,et al.  Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models. , 1990, Biorheology.

[7]  Josef Köhler,et al.  Zur Spaltströmung durch künstliche Herzklappen , 1989 .

[8]  H Reul,et al.  In vitro comparison of aortic heart valve prostheses. Part 1: Mechanical valves. , 1988, The Journal of thoracic and cardiovascular surgery.

[9]  G Rosenberg,et al.  An experimental study of Newtonian and non-Newtonian flow dynamics in a ventricular assist device. , 1987, Journal of biomechanical engineering.

[10]  J Fisher,et al.  Design of a function test apparatus for prosthetic heart valves. Initial results in the mitral position. , 1986, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[11]  R. Pichel,et al.  A comparative in vitro study of the closing characteristics of Björk-Shiley and Bicer-Val tilting disc mitral valve prostheses. , 1986, Journal of biomedical engineering.

[12]  H Reul,et al.  Cardiovascular simulation models. , 1984, Life support systems : the journal of the European Society for Artificial Organs.

[13]  H Reul,et al.  In-vitro wall shear measurements at aortic valve prostheses. , 1984, Journal of biomechanics.

[14]  D Liepsch,et al.  Pulsatile flow of non-Newtonian fluid in distensible models of human arteries. , 1984, Biorheology.

[15]  A P Yoganathan,et al.  In-vitro fluid dynamic characteristics of the abiomed trileaflet heart valve prosthesis. , 1983, Journal of biomechanical engineering.

[16]  E. C. Harrison,et al.  Regurgitation of prosthetic heart valves: dependence on heart rate and cardiac output. , 1983, The American journal of cardiology.

[17]  L N Scotten,et al.  The Björk-Shiley and Ionescu-Shiley heart valve prostheses. In vitro comparison of their hydrodynamic performance in the mitral position. , 1983, Scandinavian journal of thoracic and cardiovascular surgery.

[18]  H. Reul,et al.  Pressure drop and velocity fields at four mechanical heart valve prostheses: Björk-Shiley Standard, Björk-Shiley Concave-Convex, Hall-Kaster and St. Jude Medical. , 1983, Life support systems : the journal of the European Society for Artificial Organs.

[19]  H. Meisner,et al.  Flow pattern and velocity field distal to human aortic and artificial heart valves as measured simultaneously by ultramicroscope anemometry in cylindrical glass tubes. , 1980, The Thoracic and cardiovascular surgeon.

[20]  D M McQueen,et al.  In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates. , 1978, The Journal of thoracic and cardiovascular surgery.

[21]  J. Wright IN VITRO COMPARISON BETWEEN THE HYDRODYNAMIC CHARACTERISTICS OF THE HANCOCK 250 (MODIFIED ORIFICE) XENOGRAFTS AND THE BJÖRK‐SHILEY AORTIC VALVE PROSTHESES , 1977, Transactions - American Society for Artificial Internal Organs.

[22]  R. L. Fortune,et al.  Regurgitation and Haemolysis in Artificial Heart Valves: An Experimental Study of Overlapping and Non-overlapping Closing Mechanisms and of Paraprosthetic Leakage , 1974 .