Gradient system providing continuously variable field characteristics

Peripheral nerve stimulation limits the use of whole‐body gradient systems capable of slew rates > 80 T/m/s and gradient strengths > 25 mT/m. The stimulation threshold depends mainly on the amplitude of the induced electric field in the patient's body, and thus can be influenced by changing the total magnetic flux of the gradient coil. A gradient system was built which allows continuous variation of the field characteristics in order to permit the use of full gradient performance without stimulation (slew rate 190–210 T/m/s, Gmax 32–40 mT/m). The system consists of a modular six‐channel gradient coil designed with a modified target field method, two three‐channel amplifiers, and a six‐channel gradient controller. It is demonstrated that two coils on one gradient axis can be driven by two amplifiers in parallel, without significant changes in image quality. Scaling of the field properties and stimulation threshold according to the current polarity and ratio of both coil sets was verified in both phantom and volunteer studies. Magn Reson Med 47:800–808, 2002. © 2002 Wiley‐Liss, Inc.

[1]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[2]  R. Bowtell,et al.  Gradient coil design using active magnetic screening , 1991, Magnetic resonance in medicine.

[3]  H. Siebold Gradient field coils for MR imaging with high spectral purity , 1990 .

[4]  Thomas F. Budinger,et al.  Thresholds for Physiological Effects Due to RF and Magnetic Fields Used in NMR Imaging , 1979, IEEE Transactions on Nuclear Science.

[5]  R. Turner A Target Field Approach To Optimal Coil Design , 1986 .

[6]  R. Rzedzian,et al.  Stimulation by Time‐varying Magnetic Fields , 1992, Annals of the New York Academy of Sciences.

[7]  G. Pausch Method for constructing a transversal gradient coil in a magnetic resonance imaging system , 1995 .

[8]  J. Patrick Reilly,et al.  Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model , 1985, IEEE Transactions on Biomedical Engineering.

[9]  R. Turner,et al.  Passive screening of switched magnetic field gradients , 1986 .

[10]  R. Turner Minimum inductance coils , 1988 .

[11]  W Huk,et al.  Peripheral nerve stimulation by time-varying magnetic fields. , 1997, Journal of computer assisted tomography.

[12]  Peter Mansfield,et al.  Snapshot echo-planar imaging methods: current trends and future perspectives , 1990, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences.

[13]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[14]  P R Harvey,et al.  Modular gradient coil: A new concept in high‐performance whole‐body gradient coil design , 1999, Magnetic resonance in medicine.

[15]  R L DeLaPaz,et al.  Echo-planar imaging. , 1994, Radiographics : a review publication of the Radiological Society of North America, Inc.

[16]  F Schmitt,et al.  Physiological effects of fast oscillating magnetic field gradients. , 1991, Journal of computer assisted tomography.

[17]  S. Pissanetzky Minimum energy MRI gradient coils of general geometry , 1992 .

[18]  F. Schmitt,et al.  Physiological Side Effects of Fast Gradient Switching , 1998 .