DIGITAL PROCESSING FOR FLUOROSCOPY-BASED INTERVERTEBRAL KINEMATIC ANALYSIS

Spinal degenerations can lead to segmental instability that is regarded as a major cause of back pain and is often an important factor in deciding on surgical fusion or prosthesis implant. The spinal kinematics analysis can provide useful information for diagnosis of instability and for the assessment of therapy and surgical treatment or for performance evaluation of disc prostheses. Digitized videofluoroscopy permits to analyze spinal motion during the full patient’s movement, with an acceptable low X-ray dose. By recognizing the vertebrae position on successive fluoroscopic images through manual selection or automated algorithms the relative kinematics between pairs of adjacent vertebrae (i.e. intervertebral kinematics) can be easily estimated. The application of fluoroscopy in the study of spinal kinematics is, however, limited because large errors can occur in the measurements. This thesis presents a comprehensive study of an innovative technique designed to provide a more accurate estimation of intervertebral kinematics. The recognition of vertebrae along the fluoroscopic sequence is implemented using an automated template-matching algorithm and involving a strong enhancement of the outline of vertebrae by resorting to derivative operators. Particular attention is devoted to fluoroscopic noise suppression and to edge-preserving filter design. Spline interpolation of the kinematic data extracted by videofluoroscopy is applied in order to obtain a more complete, continuous description of spinal kinematics and, more specifically, of instantaneous center of rotation. In the introductory part of the thesis (Chapter I and II) the motivation of the study and a survey of spinal measurement techniques are given. The feasibility of videofluoroscopic analysis of spinal motion is extensively discussed. In Chapter III common kinematic parameters (such as range of motion, center of rotation, etc.) utilized for describing intervertebral spinal behaviour are presented, providing particular emphasis on the difficulty to determine a “boundary” between normal and abnormal measures of segmental kinematics for the definition of spinal instability. An extensive review of recent proposals in analysis of segmental motion is reported. Manual recognition of anatomical landmarks in videofluoroscopy can be very problematic. It is also well-known that derivative operators, commonly used for automatic recognition, are highly sensitive to noise. Chapter IV attempts to address this issue: fluoroscopic noise model, also in presence of non-linear gray-level transformations for image enhancement, is presented; various denoising algorithms specifically designed for signal-dependent noise and AWGN are examined and a performance comparison among them is carried out. In Chapter V the proposed algorithm for automated vertebrae recognition is described and its performance is experimentally analyzed on fluoroscopic images of a calibration model. A comparison with a manual selection procedure and other automated algorithms on real lumbar fluoroscopic sequences is presented. In Chapter VI a continuous-time description of intervertebral motion by cubic smoothing spline interpolation is presented and the evaluation of instantaneous center of rotation of spinal motion segments by videofluoroscopy is discussed.

[1]  M J Pearcy,et al.  Mechanical function of the human lumbar interspinous and supraspinous ligaments. , 1990, Journal of biomedical engineering.

[2]  W C Hayes,et al.  A Biomechanical Analysis of the Clinical Stability of the Lumbar and Lumbosacral Spine , 1982, Spine.

[3]  Robert Allen,et al.  Spine kineamtics: a digital videofluoroscopic technique☆ , 1989 .

[4]  Brendan McCane,et al.  Automated tracking in digitized videofluoroscopy sequences for spine kinematic analysis , 2009, Image Vis. Comput..

[5]  G B Andersson,et al.  The Effect of Disc Degeneration and Facet Joint Osteoarthritis on the Segmental Flexibility of the Lumbar Spine , 2000, Spine.

[6]  R. Hinrichs,et al.  Endpoint error in smoothing and differentiating raw kinematic data: an evaluation of four popular methods. , 1996, Journal of biomechanics.

[7]  Thomas R Oxland,et al.  Degenerative mechanics of the lumbar spine. , 2004, The spine journal : official journal of the North American Spine Society.

[8]  Simon X. Yang,et al.  Relationship between pain and vertebral motion in chronic low-back pain subjects. , 2002, Clinical biomechanics.

[9]  R. Wilcox An introduction to basic mechanics , 2006 .

[10]  M. Rousseau,et al.  The instant axis of rotation influences facet forces at L5/S1 during flexion/extension and lateral bending , 2006, European Spine Journal.

[11]  G. Messina,et al.  Fast method for noise level estimation and denoising [image processing example] , 2005, 2005 Digest of Technical Papers. International Conference on Consumer Electronics, 2005. ICCE..

[12]  D. Andrews,et al.  Determining the optimal system-specific cut-off frequencies for filtering in-vitro upper extremity impact force and acceleration data by residual analysis. , 2011, Journal of biomechanics.

[13]  Stephen Lemos,et al.  A New Technique , 2004, The American journal of sports medicine.

[14]  K. Egiazarian,et al.  Noise Measurement for Raw-Data of Digital Imaging Sensors by Automatic Segmentation of Nonuniform Targets , 2007, IEEE Sensors Journal.

[15]  M M Panjabi,et al.  Centers and angles of rotation of body joints: a study of errors and optimization. , 1979, Journal of biomechanics.

[16]  M J Pearcy,et al.  Correlation between radiographic and clinical measurement of lumbar spine movement. , 1983, British journal of rheumatology.

[17]  Gung Feng,et al.  Data smoothing by cubic spline filters , 1998, IEEE Trans. Signal Process..

[18]  M. Panjabi The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. , 1992, Journal of spinal disorders.

[19]  Youngbae Hwang,et al.  Color edge detection using the Skellam distribution as a sensor noise model , 2007, SICE Annual Conference 2007.

[20]  S. Woo,et al.  A rigid-body method for finding centers of rotation and angular displacements of planar joint motion. , 1987, Journal of biomechanics.

[21]  M J Pearcy,et al.  New method for the non-invasive three-dimensional measurement of human back movement. , 1989, Clinical biomechanics.

[22]  J H Challis,et al.  Estimation of the finite center of rotation in planar movements. , 2001, Medical engineering & physics.

[23]  E. Shwedyk,et al.  P060 Biomechanic signal filtering for dynamic analysis purpose: A quanittative comparison between different methods , 1998 .

[24]  Michael Elad,et al.  Image Denoising Via Sparse and Redundant Representations Over Learned Dictionaries , 2006, IEEE Transactions on Image Processing.

[25]  Nikolai Bogduk,et al.  Chapter 2 – Biomechanics of the Cervical Spine , 2002 .

[26]  H. Junghanns Spondylolisthesen ohne Spalt im Zwischengelenkstück , 1931, Archiv für orthopädische und Unfall-Chirurgie, mit besonderer Berücksichtigung der Frakturenlehre und der orthopädisch-chirurgischen Technik.

[27]  Manohar M. Panjabi,et al.  Clinical Biomechanics of the Spine , 1978 .

[28]  H. van Mameren,et al.  Cervical Spine Motion in the Sagittal Plane II: Position of Segmental Averaged Instantaneous Centers of Rotation -A Cineradiographic Study , 1992, Spine.

[29]  G. Ferrigno,et al.  Comparison between the more recent techniques for smoothing and derivative assessment in biomechanics , 1992, Medical and Biological Engineering and Computing.

[30]  M. Tulder,et al.  Low back pain (non-specific) , 2007 .

[31]  R Allen,et al.  Spine kinematics: a digital videofluoroscopic technique , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[32]  G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. , 1989, Acta orthopaedica Scandinavica. Supplementum.

[33]  C Simonis Parallel calculation and analysis of spine kinematic parameters using videofluoroscopy and image processing. , 1994 .

[34]  S. Mercer,et al.  Biomechanics of the cervical spine. I: Normal kinematics. , 2000, Clinical biomechanics.

[35]  S. Jakhere,et al.  Imaging in clinical medicine: traumatic pseudomeningocoele , 2011, The Libyan journal of medicine.

[36]  H Nägerl,et al.  How do spinal segments move? , 2009, Journal of biomechanics.

[37]  P. Dolan,et al.  The relationship between EMG activity and extensor moment generation in the erector spinae muscles during bending and lifting activities. , 1993, Journal of biomechanics.

[38]  S. Santavirta,et al.  Disc degeneration and angular movement of the lumbar spine: comparative study using plain and flexion-extension radiography and discography. , 1991, Journal of spinal disorders.

[39]  J W Frymoyer,et al.  Segmental Motion and Instability , 1987, Spine.

[40]  E. Sariali,et al.  In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow up evaluation , 2006, European Spine Journal.

[41]  A. A. Sawchuk,et al.  Nonlinear Restoration Of Filtered Images With Poisson Noise , 1979, Optics & Photonics.

[42]  Stability of the human spine: a biomechanical study. , 1988, Clinical biomechanics.

[43]  N. Bogduk Clinical Anatomy of the Lumbar Spine and Sacrum , 1997 .

[44]  Ac Breen The measurement of the kinematics of the human spine using videofluoroscopy and image processing. , 1991 .

[45]  E. Teo,et al.  Validation of T10-T11 Finite Element Model and Determination of Instantaneous Axes of Rotations in Three Anatomical Planes , 2003, Spine.

[46]  M. Pearcy,et al.  Abnormal Motion in Spondylolytic Spondylolisthesis , 2005, Spine.

[47]  Lindsay J. Rowe,et al.  The essentials of skeletal radiology , 1987 .

[48]  Alex. B. W. Kennedy,et al.  The Kinematics of Machinery: Outlines of a Theory of Machines , 2006 .

[49]  V. Devlin,et al.  Instantaneous Axis of Rotation as a Function of the Three Columns of the Spine , 1992, Spine.

[50]  Alessandro Foi,et al.  Clipped noisy images: Heteroskedastic modeling and practical denoising , 2009, Signal Process..

[51]  Xin Wang,et al.  Blind Image Quality Assessment for Measuring Image Blur , 2008, 2008 Congress on Image and Signal Processing.

[52]  L. Claes,et al.  The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis. , 2008, Clinical biomechanics.

[53]  D S McNally,et al.  'Stress' distributions inside intervertebral discs. The effects of age and degeneration. , 1996, The Journal of bone and joint surgery. British volume.

[54]  M J Pearcy,et al.  Instantaneous Axes of Rotation of the Lumbar Intervertebral Joints , 1988, Spine.

[55]  C J Kotre,et al.  Noise and threshold contrast characteristics of a digital fluorographic system. , 1986, Physics in medicine and biology.

[56]  Paolo Bifulco,et al.  Estimation of out-of-plane vertebra rotations on radiographic projections using CT data: a simulation study. , 2002, Medical engineering & physics.

[57]  B. McCane,et al.  On calculating the finite centre of rotation for rigid planar motion. , 2005, Medical engineering & physics.

[58]  T. King,et al.  Primary instability of lumbar vertebrae as a common cause of low back pain. , 1957, The Journal of bone and joint surgery. British volume.

[59]  P Bifulco,et al.  Advanced template matching method for estimation of intervertebral kinematics of lumbar spine. , 2011, Medical engineering & physics.

[60]  Luigi Paura,et al.  Noise reduction in fluoroscopic image sequences for joint kinematics analysis , 2010 .

[61]  L. Penning,et al.  Inability to prove instability. A critical appraisal of clinical-radiological flexion-extension studies in lumbar disc degeneration. , 1984, Diagnostic imaging in clinical medicine.

[62]  D. Kubein-Meesenburg,et al.  Axial rotation in the lumbar spine following axial force wrench. , 2009, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[63]  K. Wood,et al.  Radiographic Evaluation of Instability in Spondylolisthesis , 1994, Spine.

[64]  Jack T Dennerlein,et al.  Interpolation of segment Euler angles can provide a robust estimation of segment angular trajectories during asymmetric lifting tasks. , 2010, Journal of biomechanics.

[65]  M M Panjabi,et al.  Thoracic spine centers of rotation in the sagittal plane , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[66]  C. Reinsch Smoothing by spline functions , 1967 .

[67]  Giuseppe Guglielmi,et al.  Lumbar intervertebral instability: a review. , 2007, Radiology.

[68]  J Chen,et al.  The limitations of the instantaneous centre of rotation in joint research. , 1999, Journal of oral rehabilitation.

[69]  Folke Knutsson,et al.  The Instability Associated with Disk Degeneration in the Lumbar Spine , 1944 .

[70]  M M Panjabi,et al.  Cervical spine motion in the sagittal plane: kinematic and geometric parameters. , 1982, Journal of Biomechanics.

[71]  J Wang,et al.  The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[72]  T M McLaughlin,et al.  Biomechanical analysis with cubic spline functions. , 1977, Research quarterly.

[73]  J. G. Skellam The frequency distribution of the difference between two Poisson variates belonging to different populations. , 1946, Journal of the Royal Statistical Society. Series A.

[74]  N. Manek,et al.  Epidemiology of back disorders: prevalence, risk factors, and prognosis , 2005, Current opinion in rheumatology.

[75]  J A Anderson,et al.  A combined flexi-rule/hydrogoniometer for measurement of lumbar spine and its sagittal movement. , 1975, Rheumatology and rehabilitation.

[76]  M M Panjabi,et al.  Errors in the center and angle of rotation of a joint: an experimental study. , 1982, Journal of biomechanical engineering.

[77]  M. Pearcy,et al.  Three-Dimensional X-ray Analysis of Normal Movement in the Lumbar Spine , 1984, Spine.

[78]  Alessandro Foi,et al.  Image Denoising by Sparse 3-D Transform-Domain Collaborative Filtering , 2007, IEEE Transactions on Image Processing.

[79]  Vivek Trikha,et al.  Clinical Study , 1961, Acta neurologica Scandinavica.

[80]  Carsten Perka,et al.  Charité total disc replacement—clinical and radiographical results after an average follow-up of 17 years , 2006, European Spine Journal.

[81]  Youngbae Hwang,et al.  Sensor noise modeling using the Skellam distribution: Application to the color edge detection , 2007, 2007 IEEE Conference on Computer Vision and Pattern Recognition.

[82]  Eric Dubois,et al.  Fast and reliable structure-oriented video noise estimation , 2005, IEEE Transactions on Circuits and Systems for Video Technology.

[83]  Yalin Zheng,et al.  Automated segmentation of lumbar vertebrae in digital videofluoroscopic images , 2004, IEEE Transactions on Medical Imaging.

[84]  Scott Tashman,et al.  A technique to measure three-dimensional in vivo rotation of fused and adjacent lumbar vertebrae. , 2008, The spine journal : official journal of the North American Spine Society.

[85]  Sean P. F. Hughes,et al.  Instantaneous Center of Rotation and Instability of the Cervical Spine: A Clinical Study , 1997, Spine.

[86]  Marc-Antoine Rousseau,et al.  Disc arthroplasty design influences intervertebral kinematics and facet forces. , 2006, The spine journal : official journal of the North American Spine Society.

[87]  Michael Kropf,et al.  Results of the Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemption Study of the ProDisc®-L Total Disc Replacement Versus Circumferential Fusion for the Treatment of 1-Level Degenerative Disc Disease , 2007, Spine.

[88]  Rolf-Rainer Grigat,et al.  Modeling and real-time estimation of signal-dependent noise in quantum-limited imaging , 2007 .

[89]  U. Tylén Radiological diagnosis. , 1981, Acta medica Scandinavica. Supplementum.

[90]  J Dimnet,et al.  The finite displacements vector's method: an application to the scoliotic spine. , 1984, Journal of biomechanics.

[91]  A. Burton,et al.  Reference values for 'normal' regional lumbar sagittal mobility. , 1988, Clinical biomechanics.

[93]  Til Aach,et al.  Noise Reduction and Image Enhancement Algorithms for Low-Dose X-Ray Fluoroscopy , 1996, Bildverarbeitung für die Medizin.

[94]  M. Pearcy,et al.  Axial rotation and lateral bending in the normal lumbar spine measured by three-dimensional radiography. , 1984, Spine.

[95]  K. Tallroth,et al.  Lumbar mobility in asymptomatic individuals. , 1992, Journal of spinal disorders.

[96]  Jack T. Dennerlein,et al.  Comparing polynomial and cubic spline interpolation of segment angles for estimating L5/S1 net moment during symmetric lifting tasks. , 2010, Journal of biomechanics.

[97]  J H Challis,et al.  An examination of procedures for determining body segment attitude and position from noisy biomechanical data. , 1995, Medical engineering & physics.

[98]  N. Semmer,et al.  The Diagnostic Accuracy of Magnetic Resonance Imaging, Work Perception, and Psychosocial Factors in Identifying Symptomatic Disc Herniations , 1995, Spine.

[99]  Luigi Paura,et al.  Noise-parameter modeling and estimation for x-ray fluoroscopy , 2011, ISABEL '11.

[100]  Maria Romano,et al.  A continuous description of intervertebral motion by means of spline interpolation of kinematic data extracted by videofluoroscopy. , 2012, Journal of biomechanics.

[101]  J Cholewicki,et al.  Method for measuring vertebral kinematics from videofluoroscopy. , 1991, Clinical biomechanics.

[102]  N. Bogduk,et al.  A Biological Basis for Instantaneous Centres of Rotation of the Vertebral Column , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[103]  J M Muggleton,et al.  Automatic location of vertebrae in digitized videofluoroscopic images of the lumbar spine. , 1997, Medical engineering & physics.

[104]  M. Pearcy,et al.  Is There Instability in Spondylolisthesis? , 1985, Spine.

[105]  Thomas W. Parks,et al.  Image denoising using total least squares , 2006, IEEE Transactions on Image Processing.

[106]  Y. Morio,et al.  Lumbar disc degeneration and segmental instability: a comparison of magnetic resonance images and plain radiographs of patients with low back pain , 2004, Archives of Orthopaedic and Trauma Surgery.

[107]  V. Argyriou,et al.  Estimation of sub-pixel motion using gradient cross-correlation , 2003 .

[108]  J. Laredo,et al.  Radiologic assessment of lumbar intervertebral instability and degenerative spondylolisthesis. , 2001, Radiologic clinics of North America.

[109]  G. Wood Data smoothing and differentiation procedures in biomechanics. , 1982, Exercise and sport sciences reviews.

[110]  M M Panjabi,et al.  The Basic Kinematics of the Human Spine: A Review of Past and Current Knowledge , 1978, Spine.

[111]  C. Reitman,et al.  Radiographic Assessment and Quantitative Motion Analysis of the Cervical Spine After Serial Sectioning of the Anterior Ligamentous Structures , 2007, Spine.

[112]  Tony Unsworth,et al.  Proceedings of the Institution of Mechanical Engineers Part H. , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[113]  R. Balderston,et al.  Evaluation of Spinal Kinematics Following Lumbar Total Disc Replacement and Circumferential Fusion Using In Vivo Fluoroscopy , 2007 .

[114]  H. Dathe,et al.  Evidence for IHA migration during axial rotation of a lumbar spine segment by using a novel high-resolution 6D kinematic tracking system. , 2004, Journal of biomechanics.

[115]  Guoan Li,et al.  In-vivo motion characteristics of lumbar vertebrae in sagittal and transverse planes. , 2010, Journal of biomechanics.

[116]  L. Jennings,et al.  On the use of spline functions for data smoothing. , 1979, Journal of biomechanics.

[117]  Barry R. Masters,et al.  Digital Image Processing, Third Edition , 2009 .

[118]  P. Axellen,et al.  Effect of lumbar orthosis on intervertebral mobility. A roentgen stereophotogrammetric analysis , 1992 .

[119]  Søren I. Olsen,et al.  Estimation of Noise in Images: An Evaluation , 1993, CVGIP Graph. Model. Image Process..

[120]  Robert D. Nowak,et al.  Wavelet-based statistical signal processing using hidden Markov models , 1998, IEEE Trans. Signal Process..

[121]  S Gracovetsky,et al.  The Nature of Instability , 1984, Spine.

[122]  Roberto Brunelli,et al.  Face Recognition: Features Versus Templates , 1993, IEEE Trans. Pattern Anal. Mach. Intell..

[123]  H. Farfan,et al.  Instability of the lumbar spine. , 1982, Clinical orthopaedics and related research.

[124]  Determination of spinal facet joint loads from extra articular strains--a theoretical validation. , 1996, Journal of biomechanics.

[125]  M. Panjabi The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement. , 1992, Journal of spinal disorders.

[126]  D. Kubein-Meesenburg,et al.  Migration of the instantaneous axis of motion during axial rotation in lumbar segments and role of the zygapophysial joints. , 2010, Acta of Bioengineering and Biomechanics.

[127]  J. Cassidy,et al.  Radiologic Diagnosis of Degenerative Lumbar Spinal Instability , 1985, Spine.

[128]  Stuart M. McGill,et al.  Creep response of the lumbar spine to prolonged full flexion. , 1992, Clinical biomechanics.

[129]  Hendrik Schmidt,et al.  Interaction Between Finite Helical Axes and Facet Joint Forces Under Combined Loading , 2008, Spine.

[130]  V. Goel,et al.  1990 Volvo Award in Clinical Sciences: The Consistency and Accuracy of Roentgenograms for Measuring Sagittal Translation in the Lumbar Vertebral Motion Segment: An Experimental Model , 1990, Spine.

[131]  Brendan McCane,et al.  Calculating the 2D motion of lumbar vertebrae using splines. , 2006, Journal of biomechanics.

[132]  P ROSENBERG The R-center method, a new method for analyzing vertebral motion by x-rays. , 1955, The Journal of the American Osteopathic Association.

[133]  G Selvik,et al.  Roentgen Stereophotogrammetric Analysis , 1990, Acta radiologica.

[134]  M M Panjabi,et al.  Optimal marker placement for calculating the instantaneous center of rotation. , 1994, Journal of biomechanics.

[135]  Aggelos K. Katsaggelos,et al.  Image sequence filtering in quantum-limited noise with applications to low-dose fluoroscopy , 1993, IEEE Trans. Medical Imaging.

[136]  M. Panjabi Clinical spinal instability and low back pain. , 2003, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[137]  M. Zanetti,et al.  MR abnormalities of the intervertebral disks and adjacent bone marrow as predictors of segmental instability of the lumbar spine , 1998, Acta radiologica.

[138]  S. Bohrer Essentials of Skeletal Radiology. 2nd ed. 2 Vols , 1996 .

[139]  S D Gertzbein,et al.  Centrode Patterns and Segmental Instability in Degenerative Disc Disease , 1985, Spine.

[140]  Yehoshua Y. Zeevi,et al.  Variational denoising of partly textured images by spatially varying constraints , 2006, IEEE Transactions on Image Processing.

[141]  Karen O. Egiazarian,et al.  Practical Poissonian-Gaussian Noise Modeling and Fitting for Single-Image Raw-Data , 2008, IEEE Transactions on Image Processing.

[142]  M H Pope,et al.  Biomechanics of the lumbar spine. , 1989, Annals of medicine.

[143]  H. Woltring On optimal smoothing and derivative estimation from noisy displacement data in biomechanics , 1985 .

[144]  I J Schoenberg,et al.  SPLINE FUNCTIONS AND THE PROBLEM OF GRADUATION. , 1964, Proceedings of the National Academy of Sciences of the United States of America.

[145]  M. Wachowski,et al.  Mechanical properties of cervical motion segments. , 2007 .

[146]  John A. Hipp,et al.  Threshold Cervical Range-of-Motion Necessary to Detect Abnormal Intervertebral Motion in Cervical Spine Radiographs , 2008, Spine.

[147]  Jennifer M Muggleton,et al.  An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data , 2006, BMC musculoskeletal disorders.

[148]  Thomas R Oxland,et al.  Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. , 2006, Journal of biomechanics.

[149]  H. Tsuji,et al.  Motion characteristic of the normal lumbar spine in young adults: instantaneous axis of rotation and vertebral center motion analyses. , 1990, Journal of spinal disorders.

[150]  Maria Romano,et al.  2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment , 2010, EURASIP J. Adv. Signal Process..

[151]  I. J. Schoenberg,et al.  SPLINE FUNCTIONS AND THE PROBLEM OF GRADUATION , 1964 .

[152]  H. Farfan,et al.  The instantaneous center of rotation of the third lumbar intervertebral joint. , 1971, Journal of biomechanics.

[153]  Maria Romano,et al.  Vertebrae tracking through fluoroscopic sequence: A novel approach , 2009 .

[154]  Rolando Garcia,et al.  A Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemptions Study of Lumbar Total Disc Replacement With the CHARITÉ™ Artificial Disc Versus Lumbar Fusion: Part I: Evaluation of Clinical Outcomes , 2005, Spine.

[155]  J. Le Huec,et al.  Clinical results of Maverick lumbar total disc replacement: two-year prospective follow-up. , 2005, The Orthopedic clinics of North America.

[156]  M. Panjabi,et al.  An Analysis of Errors in Kinematic Parameters Associated with in Vivo Functional Radiographs , 1992, Spine.

[157]  S D Gertzbein,et al.  Determination of a Locus of Instantaneous Centers of Rotation of the Lumbar Disc by Moiré Fringes: A New Technique , 1984, Spine.

[158]  P. Bifulco,et al.  Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics , 2006, Medical and Biological Engineering and Computing.

[159]  A. Schultz,et al.  Mechanical Properties of Human Lumbar Spine Motion Segments: Influences of Age, Sex, Disc Level, and Degeneration , 1979, Spine.