Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw Insertion

Study Design. In vitro study to determine occupational radiation exposure during lumbar fluoroscopy. Objectives. To assess radiation exposure to the spine surgeon during fluoroscopically assisted thoracolumbar pedicle screw placement. Summary of Background Data. Occupational radiation exposure during a variety of fluoroscopically assisted musculoskeletal procedures has been previously evaluated. No prior study has assessed fluoroscopy-related radiation exposure to the spine surgeon. Methods. Bilateral pedicle screw placement (T11–S1) was performed in six cadavers using lateral fluoroscopic imaging. Radiation dose rates to the surgeon’s neck, torso, and dominant hand were measured with dosimeter badges and thermolucent dosimeter (TLD) rings. Radiation levels were also quantified at various distances from the dorsal lumbar surface using an ion chamber radiation survey meter. Results. The mean dose rate to the neck was 8.3 mrem/min. The dose rate to the torso was greatest when the surgeon was positioned ipsilateral to the beam source (53.3 mrem/min, compared with 2.2 mrem/min on the contralateral side). The average hand dose rate was 58.2 mrem/min. A significant increase in hand dose rate was associated with placement of screws ipsilateral to the beam source (P = 0.0005) and larger specimens (P = 0.0007). Radiation levels significantly decreased as distance from the beam source and dorsal body surface increased. The greatest levels of radiation were noted on the side where the primary radiograph beam entered the cadaver. Conclusion. Fluoroscopically assisted thoracolumbar pedicle screw placement exposes the spine surgeon to significantly greater radiation levels than other, nonspinal musculoskeletal procedures that involve the use of a fluoroscope. In fact, dose rates are up to 10–12 times greater. Spine surgeons performing fluoroscopically assisted thoracolumbar procedures should monitor their annual radiation exposure. Measures to reduce radiation exposure and surgeon awareness of high-exposure body and hand positions are certainly called for.

[1]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[2]  J. Hendry,et al.  Radiobiology for the Radiologist , 1979, British Journal of Cancer.

[3]  C E Land,et al.  Estimating cancer risks from low doses of ionizing radiation. , 1980, Science.

[4]  A A Giachino,et al.  Irradiation of the surgeon during pinning of femoral fractures. , 1980, The Journal of bone and joint surgery. British volume.

[5]  J. Bailar,et al.  The contribution of ionizing radiation to cancer mortality in the United States. , 1980, Preventive medicine.

[6]  An assessment of the radiation dose received by staff using fluoroscopic equipment. , 1982, The British journal of radiology.

[7]  M. Davis,et al.  Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. , 1983, The Journal of bone and joint surgery. American volume.

[8]  T. P. Barry Radiation Exposure to an Orthopedic Surgeon , 1984, Clinical orthopaedics and related research.

[9]  Juan M. Taveras,et al.  Radiology : diagnosis, imaging, intervention , 1986 .

[10]  B. Browner,et al.  Radiation exposure to the surgeon during closed interlocking intramedullary nailing. , 1987, The Journal of bone and joint surgery. American volume.

[11]  T D Bunker,et al.  Radiation dosage during AO locking femoral nailing. , 1988, Injury.

[12]  Radiation exposure from fluoroscopy during orthopedic surgical procedures. , 1990, Clinical orthopaedics and related research.

[13]  J. Boone,et al.  Radiation exposure to angiographers under different fluoroscopic imaging conditions. , 1991, Radiology.

[14]  D. Stoker Ionising radiation and the orthopaedic surgeon. , 1992, The Journal of bone and joint surgery. British volume.

[15]  K E Goldstone,et al.  Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control. , 1993, The British journal of radiology.

[16]  J. Cobb,et al.  Hazard of ionizing radiation to trauma surgeons: reducing the risk. , 1993, Injury.

[17]  R P Rossi,et al.  A survey of fluoroscopic exposure rates: AAPM Task Group No. 11 Report. , 1993, Medical physics.

[18]  J. Roelandt,et al.  Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering. , 1994, Circulation.

[19]  B. Archer,et al.  Exposure rates during special procedures with C-arm type fluoroscopic systems. , 1994, Radiology.

[20]  S A Riley,et al.  Exposure of the orthopaedic surgeon to radiation. , 1994, The Journal of bone and joint surgery. American volume.

[21]  B. J. Larson,et al.  Radiation Exposure During Fluoroarthroscopically Assisted Anterior Cruciate Reconstruction , 1995, The American journal of sports medicine.

[22]  M. McKetty,et al.  Study of radiation doses to personnel in a cardiac catheterization laboratory. , 1996, Health physics.

[23]  J. Pahira,et al.  Radiation risk to the urologist during endourologic procedures, and a new shield that reduces exposure. , 1996, Urology.

[24]  Breast cancer among radiologic technologists. , 1996, JAMA.

[25]  M. Goodsitt,et al.  Reduction of radiation dose in pediatric patients using pulsed fluoroscopy. , 1996, AJR. American journal of roentgenology.

[26]  S Rudin,et al.  Primary beam exposure outside the fluoroscopic field of view. , 1997, Medical physics.

[27]  T. Dipasquale,et al.  Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?". , 1997, Journal of orthopaedic trauma.

[28]  M. Finkelstein Is brain cancer an occupational disease of cardiologists? , 1998, The Canadian journal of cardiology.

[29]  P M Rommens,et al.  Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. , 1998, Injury.

[30]  J. McGuigan,et al.  Ionising radiation during internal fixation of extracapsular neck of femur fractures. , 1998, Injury.

[31]  S. Skjeldal,et al.  Interlocking medullary nails — Radiation doses in distal targeting , 2004, Archives of orthopaedic and traumatic surgery.