Fracture mechanics of bone--the effects of density, specimen thickness and crack velocity on longitudinal fracture.

The fracture mechanics parameters of critical stress intensity factor (Kc) and critical strain energy release rate (Gc) for longitudinal fracture of bovine tibia cortical bone were determined by the compact tension method. It was demonstrated that, for a given bone density, Kc and Gc depended on the loading rate, and resultant crack velocity, with a maximum in fracture toughness (Kc approximately 6.3 MNm-3/2, Gc approximately 2900 Jm-2) at a crack velocity approximately 10(-3) ms-1. For a given loading rate, or crack velocity, an increase in bone density, in the range from 1.92 to 2.02 Mgm-3, produced increases in Kc and Gc, but a variation in specimen thickness (from 0.5 to 2 mm) had no effect on the measured fracture mechanics parameters.