Sixteen Gauge biopsy needles are better and safer than 18 Gauge in native and transplant kidney biopsies

Background Kidney biopsies are essential for optimal diagnosis and treatment. Purpose To examine if quality and safety aspects differ between types and sizes of biopsy needles in native and transplant kidneys. Material and Methods A total of 1299 consecutive biopsies (1039 native and 260 transplant kidneys) were included. Diagnostic quality, needle size and type, clinical data and complications were registered. Eight-three percent of the data were prospective. Results In native kidney biopsies, 16 Gauge (G) needles compared to 18 G showed more glomeruli per pass (11 vs. 8, P < 0.001) with less complications. Sub-analysis in native kidney biopsies revealed that 18 G 19-mm side-notch needles resulted in more major (11.3% vs. 3%; odds ratio [OR], 4.1; 95% confidence interval [CI], 1.4–12.3) and overall complications (12.4% vs. 4.8%; OR, 2.8; 95% CI, 1.1–7.1) in women than in men. If the physician had performed less compared to more than four native kidney biopsies per year, minor (3.5% vs. 1.4%; OR, 2.6; 95% CI, 1.1–6.2) and overall complications (11.5% vs. 7.4%; OR, 1.6; 95% CI, 1.1–2.5) were more common. In transplant kidney biopsies, 16 G needles compared to 18 G resulted in more glomeruli per pass (12 vs. 8, P < 0.001). No differences existed in frequency of biopsy complications. The localization of performing biopsies was not a risk factor to develop complications. Conclusion Kidney biopsies taken by 16 G needles result in better histological quality and lower frequency of complications compared to 18 G. For native kidney biopsies the performer of the biopsy should do at least four biopsies per year.

[1]  Bjoern Peters,et al.  A study of clinical complications and risk factors in 1001 native and transplant kidney biopsies in Sweden , 2014, Acta radiologica.

[2]  J. Mai,et al.  Is bigger better? A retrospective analysis of native renal biopsies with 16 Gauge versus 18 Gauge automatic needles , 2013, Nephrology.

[3]  B. Rovin,et al.  When Size Matters: Diagnostic Value of Kidney Biopsy according to the Gauge of the Biopsy Needle , 2013, American Journal of Nephrology.

[4]  L. Bostad,et al.  Safety and complications of percutaneous kidney biopsies in 715 children and 8573 adults in Norway 1988-2010. , 2012, Clinical journal of the American Society of Nephrology : CJASN.

[5]  W. Whittier,et al.  Complications of the percutaneous kidney biopsy. , 2012, Advances in chronic kidney disease.

[6]  H. Gröne,et al.  Are tissue samples from two different anatomical areas of the kidney necessary for adequate diagnosis? , 2010, Clinical nephrology.

[7]  M. Brisson,et al.  Percutaneous US-guided renal biopsy: a retrospective study comparing the 16-gauge end-cut and 14-gauge side-notch needles. , 2010, Journal of vascular and interventional radiology : JVIR.

[8]  Tom Greene,et al.  Expressing the Modification of Diet in Renal Disease Study equation for estimating glomerular filtration rate with standardized serum creatinine values. , 2007, Clinical chemistry.

[9]  Anke Schwarz,et al.  Safety and Adequacy of Renal Transplant Protocol Biopsies , 2005, American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons.

[10]  S. Korbet Percutaneous renal biopsy. , 2002, Seminars in nephrology.

[11]  S. White,et al.  A prospective randomized trial of three different sizes of core-cutting needle for renal transplant biopsy. , 2000, Kidney international.

[12]  H. E. Hansen,et al.  The Banff 97 working classification of renal allograft pathology. , 1999, Kidney international.

[13]  J. Cronan,et al.  Percutaneous biopsy in diffuse renal disease: comparison of 18- and 14-gauge automated biopsy devices. , 1998, Journal of vascular and interventional radiology : JVIR.

[14]  M. Mahoney,et al.  Safety and efficacy of kidney transplant biopsy: Tru-Cut needle vs sonographically guided Biopty gun. , 1993, AJR. American journal of roentgenology.

[15]  R. Punia,et al.  Comparison of diagnostic quality of kidney biopsy obtained using 16G and 18G needles in patients with diffuse renal disease. , 2012, Saudi journal of kidney diseases and transplantation : an official publication of the Saudi Center for Organ Transplantation, Saudi Arabia.

[16]  W. Whittier,et al.  Timing of complications in percutaneous renal biopsy. , 2004, Journal of the American Society of Nephrology : JASN.

[17]  J. Cameron,et al.  The introduction of renal biopsy into nephrology from 1901 to 1961: a paradigm of the forming of nephrology by technology. , 1997, American journal of nephrology.

[18]  R. Wigton,et al.  Procedural skills of practicing nephrologists. A national survey of 700 members of the American College of Physicians. , 1990, Annals of Internal Medicine.