Physiologically gated microbeam radiation using a field emission x-ray source array.

PURPOSE Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. METHODS The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic(©) films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. RESULTS The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In the in vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. CONCLUSIONS The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

[1]  Yuan Cheng,et al.  Electron field emission from carbon nanotubes , 2003, Comptes Rendus Physique.

[2]  Yuan Cheng,et al.  A nanotube-based field emission x-ray source for microcomputed tomography , 2005 .

[3]  Guohua Cao,et al.  Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray. , 2010, Medical physics.

[4]  Ke Sheng,et al.  Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI. , 2009, Medical physics.

[5]  Alberto Bravin,et al.  Preferential effect of synchrotron microbeam radiation therapy on intracerebral 9L gliosarcoma vascular networks. , 2010, International journal of radiation oncology, biology, physics.

[6]  P. Spanne,et al.  Microbeam radiation therapy. , 1992 .

[7]  Otto Zhou,et al.  Stationary scanning x-ray source based on carbon nanotube field emitters , 2005 .

[8]  F. Avraham Dilmanian,et al.  Murine EMT-6 Carcinoma: High Therapeutic Efficacy of Microbeam Radiation Therapy , 2003, Radiation research.

[9]  Geraldine Le Duc,et al.  Increase of lifespan for glioma-bearing rats by using minibeam radiation therapy. , 2012, Journal of synchrotron radiation.

[10]  J F Hainfeld,et al.  X-ray microbeams: Tumor therapy and central nervous system research. , 2005, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[11]  C. P. Baker,et al.  Histopathologic effect of high-energy-particle microbeams on the visual cortex of the mouse brain. , 1961, Radiation research.

[12]  S. Cherry,et al.  Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating , 2005, Physics in medicine and biology.

[13]  Guohua Cao,et al.  Carbon Nanotube based X-ray Sources: Applications in Pre-Clinical and Medical Imaging. , 2011, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[14]  Tetsuya Yuasa,et al.  Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[15]  Linda J. Kuo,et al.  γ-H2AX - A Novel Biomarker for DNA Double-strand Breaks , 2008 .

[16]  Alberto Bravin,et al.  Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose. , 2009, Physics in medicine and biology.

[17]  P Laganis,et al.  A first generation compact microbeam radiation therapy system based on carbon nanotube X-ray technology. , 2013, Applied physics letters.

[18]  D N Slatkin,et al.  Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[19]  A Bravin,et al.  Radiosurgical palliation of aggressive murine SCCVII squamous cell carcinomas using synchrotron-generated X-ray microbeams. , 2006, The British journal of radiology.

[20]  A Bravin,et al.  The radiotherapy clinical trials projects at the ESRF: technical aspects. , 2008, European journal of radiology.

[21]  Guohua Cao,et al.  Prospective respiratory gated carbon nanotube micro computed tomography. , 2011, Academic radiology.

[22]  Yolanda Prezado,et al.  Survival Analysis of F98 Glioma Rat Cells Following Minibeam or Broad-Beam Synchrotron Radiation Therapy , 2011, Radiation oncology.

[23]  W Thomlinson,et al.  Research at the European Synchrotron Radiation Facility medical beamline. , 2000, Cellular and molecular biology.

[24]  Lei Zhang,et al.  Image-guided microbeam irradiation to brain tumour bearing mice using a carbon nanotube x-ray source array , 2014, Physics in medicine and biology.

[25]  R Peng,et al.  A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source , 2009, Physics in medicine and biology.

[26]  David W. Archer,et al.  Microbeam radiation therapy , 1999, Optics & Photonics.

[27]  K. Uesugi,et al.  Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy. , 2008, Medical physics.