Combined System for Harmonic Suppression and Reactive Power Compensation

In this paper, a combined system of static Var compensator (SVC) and active power filter (APF) was proposed. The system has the function of power factor correction, voltage stability, and harmonic suppression. The SVC, which consists of delta-connected thyristor-controlled reactor (TCR) and Y-connected passive power filter (PPF), is mainly for voltage stability and power factor correction. The small rating APF is used to filter harmonics generated by the nonlinear load and the TCR in the SVC and to suppress possible resonance between the grid and the PPFs. The configuration and principle of the combined system were discussed first, and then, the control method of the combined system was presented. An optimal nonlinear proportional-integral control was proposed to improve the dynamic response and decrease the steady-state error of the SVC. Harmonic detection with precompensation method and improved generalized integrator control were proposed to improve the performance of APF. The new combined system is compared to classical SVC. It is implemented in a 200-kVA prototype in the laboratory. Simulation and experimental results show that the proposed combined configuration can effectively stabilize system voltage, correct power factor, and suppress harmonic currents.

[1]  Ming-Ji Yang,et al.  Model Reference Adaptive Control Design for a Shunt Active Power Filter System , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[2]  Prasad Enjeti,et al.  A new hybrid active power filter (APF) topology , 2002 .

[3]  Zhang Chao,et al.  Detecting and close-loop control methods for selective-harmonic-compensation active power filter , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..

[4]  Tang Jie Injection Branch Design of Injection Type Hybrid Active Power Filter , 2007 .

[5]  Patricio Salmerón,et al.  Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results , 2008, IEEE Transactions on Industrial Electronics.

[6]  Maurizio Cirrincione,et al.  A Single-Phase DG Generation Unit with Shunt Active Power Filter Capability by Adaptive Neural Filtering , 2008, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[7]  Liuchen Chang,et al.  A hybrid neuro-fuzzy system for robot control , 1995, 1995 IEEE International Conference on Systems, Man and Cybernetics. Intelligent Systems for the 21st Century.

[8]  Zeliang Shu,et al.  Steady-State and Dynamic Study of Active Power Filter With Efficient FPGA-Based Control Algorithm , 2008, IEEE Transactions on Industrial Electronics.

[9]  Takafumi Maeda,et al.  Effective Application of Static Var Compensators to Damp Oscillations , 1985, IEEE Power Engineering Review.

[10]  Shuai Zhi-kang Stability of Hybrid Shunt Active Power Filter , 2008 .

[11]  Luis Marroyo,et al.  Individual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[12]  Wei Zhao,et al.  A Novel Three-Phase Hybrid Active Power Filter With a Series Resonance Circuit Tuned at the Fundamental Frequency , 2009, IEEE Transactions on Industrial Electronics.

[13]  Ning Zhu,et al.  Analysis of a static VAr compensator using the dispatcher training simulator , 1995 .

[14]  L. Gyugyi,et al.  Active ac power filters , 1976 .

[15]  H. Akagi,et al.  A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[16]  Po-Tai Cheng,et al.  Hybrid solutions for improving passive filter performance in high power applications , 1997 .

[17]  H. Stemmler,et al.  Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[18]  Suttichai Premrudeepreechacharn,et al.  Active power filter for three-phase four-wire electric systems using neural networks , 2002 .

[19]  Fei Lin,et al.  Nonlinear PI control for three-phase PWM AC-DC converter , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[20]  Yuan-Yih Hsu,et al.  A Minimal Harmonic Controller for a STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[21]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[22]  Takeshi Furuhashi,et al.  A study on the theory of instantaneous reactive power , 1990 .

[23]  Luo An A new variable structure control for active power filters , 2004 .

[24]  Paolo Mattavelli,et al.  Comparison of current control techniques for active filter applications , 1998, IEEE Trans. Ind. Electron..

[25]  Jing Zhang,et al.  A Novel SVC Allocation Method for Power System Voltage Stability Enhancement by Normal Forms of Diffeomorphism , 2007, IEEE Transactions on Power Systems.

[26]  Po-Tai Cheng,et al.  Hybrid solutions for improving passive filter performance in high power applications , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[27]  Frede Blaabjerg,et al.  Shunt Active-Power-Filter Topology Based on Parallel Interleaved Inverters , 2008, IEEE Transactions on Industrial Electronics.

[28]  Heiko Schwarz,et al.  Performance Analysis of SVC , 2007, IEEE Transactions on Circuits and Systems for Video Technology.

[29]  Tang Jie The Research of the Delay Based on Digital Control System of Resonance Injection Active Power Filter , 2007 .

[30]  Pericle Zanchetta,et al.  Predictive Current Control for Multilevel Active Rectifiers With Reduced Switching Frequency , 2008, IEEE Transactions on Industrial Electronics.

[31]  L. Xu,et al.  Advanced SVC control for damping power system oscillations , 1991 .

[32]  Hurng-Liahng Jou,et al.  Novel Circuit Topology for Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Delivery.

[33]  Qiongq Chen,et al.  The application and optimization of C-type filter in a combined harmonic power filter , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[34]  Kanako Miura,et al.  Visual servoing without Jacobian using modified simplex optimization , 2004, SICE 2004 Annual Conference.

[35]  Chengyong Zhao,et al.  Parameters Optimization of VSC-HVDC Control System Based on Simplex Algorithm , 2007, 2007 IEEE Power Engineering Society General Meeting.

[36]  M.H. Abdel-Rahman,et al.  New static var compensator control strategy and coordination with under-load tap changer , 2006, IEEE Transactions on Power Delivery.