Multichannel thin-film electrode for intramuscular electromyographic recordings.

It is currently not possible to record electromyographic (EMG) signals from many locations concurrently inside the muscle in a single wire electrode system. We developed a thin-film wire electrode system for multichannel intramuscular EMG recordings. The system was fabricated using a micromachining process, with a silicon wafer as production platform for polyimide-based electrodes. In the current prototype, the flexible polymer structure is 220 microm wide, 10 microm thick, and 1.5 cm long, and it has eight circular platinum-platinum chloride recording sites of 40-microm diameter distributed along the front and back surfaces with 1,500-microm intersite spacing. The system prototype was tested in six experiments where the electrode was implanted into the medial head of the gastrocnemius muscle of rabbits, perpendicular to the pennation angle of the muscle fibers. Asynchronous motor unit activity was induced by eliciting the withdrawal reflex or sequential crushes of the sciatic nerve using a pair of forceps. Sixty-seven motor units were identified from these recordings. In the bandwidth 200 Hz to 5 kHz, the peak-to-peak amplitude of the action potentials of the detected motor units was 75 +/- 12 muV and the root mean square of the noise was 1.6 +/- 0.4 muV. The noise level and amplitude of the action potentials were similar for measures separated by up to 40 min. The experimental tests demonstrated that thin film is a promising technology for a new type of flexible-wire intramuscular EMG recording system with multiple detection sites.

[1]  E. Adrian,et al.  The discharge of impulses in motor nerve fibres , 1929, The Journal of physiology.

[2]  E. Adrian,et al.  The discharge of impulses in motor nerve fibres , 1928, The Journal of physiology.

[3]  F. Buchthal,et al.  Multielectrode study of the territory of a motor unit. , 1957, Acta physiologica Scandinavica.

[4]  G. J. Romanes,et al.  Current Problems of Lower Vertebrate Phylogeny. , 1969 .

[5]  C. D. De Luca,et al.  An electrode for recording single motor unit activity during strong muscle contractions. , 1972, IEEE transactions on bio-medical engineering.

[6]  S. Sunderland Nerves and nerve injuries , 1978 .

[7]  Ronald S. Lefever,et al.  A Procedure for Decomposing the Myoelectric Signal Into Its Constituent Action Potentials - Part I: Technique, Theory, and Implementation , 1982, IEEE Transactions on Biomedical Engineering.

[8]  Jiri Silny,et al.  Spatial Filtering of Noninvasive Multielectrode EMG: Part I-Introduction to Measuring Technique and Applications , 1987, IEEE Transactions on Biomedical Engineering.

[9]  G. A. Robinson,et al.  A stable, selective electrode for recording single motor-unit potentials in humans , 1988, Experimental Neurology.

[10]  K. Horch,et al.  Muscle recruitment with intrafascicular electrodes , 1991, IEEE Transactions on Biomedical Engineering.

[11]  E Stålberg,et al.  Scanning EMG in normal muscle and in neuromuscular disorders. , 1991, Electroencephalography and clinical neurophysiology.

[12]  T. G. McNaughton,et al.  Metallized polymer fibers as leadwires and intrafascicular microelectrodes , 1996, Journal of Neuroscience Methods.

[13]  R H Westgaard,et al.  Motor unit substitution in long-duration contractions of the human trapezius muscle. , 1999, Journal of neurophysiology.

[14]  R.B. Stein,et al.  Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes , 1999, IEEE Transactions on Biomedical Engineering.

[15]  D F Stegeman,et al.  Multi-channel surface EMG in clinical neurophysiology. , 2000, Supplements to Clinical neurophysiology.

[16]  D. Kipke,et al.  Development of the thin-film longitudinal intra-fascicular electrode , 2000 .

[17]  T. Stieglitz,et al.  Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .

[18]  T. Stieglitz,et al.  High density interconnects and flexible hybrid assemblies for active biomedical implants , 2001 .

[19]  R. Enoka,et al.  Motor unit physiology: Some unresolved issues , 2001, Muscle & nerve.

[20]  D. Stegeman,et al.  Multichannel surface EMG: Basic aspects and clinical utility , 2003, Muscle & nerve.

[21]  Alexander Adam,et al.  Recruitment order of motor units in human vastus lateralis muscle is maintained during fatiguing contractions. , 2003, Journal of neurophysiology.

[22]  U. Eysel,et al.  Cortical activation via an implanted wireless retinal prosthesis. , 2005, Investigative ophthalmology & visual science.

[23]  Kevin C. McGill,et al.  EMGLAB: An interactive EMG decomposition program , 2005, Journal of Neuroscience Methods.

[24]  S. Kammer,et al.  Acute Performance of the Thin-Film Longitudinal Intra-Fascicular Electrode , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[25]  K. Horch,et al.  An intrafascicular electrode for recording of action potentials in peripheral nerves , 2006, Annals of Biomedical Engineering.

[26]  K. Horch,et al.  Chronically implanted intrafascicular recording electrodes , 2006, Annals of Biomedical Engineering.

[27]  Ken Yoshida,et al.  Assessment of Biocompatibility of Chronically Implanted Polyimide and Platinum Intrafascicular Electrodes , 2007, IEEE Transactions on Biomedical Engineering.