Improved frequency/voltage converters for fast quartz crystal microbalance applications.

The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1 kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10 mVHz, for a frequency shift resolution of 0.1 Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5 to 10 MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.

[1]  Fred J. Taylor,et al.  Electronic filter design handbook , 1981 .

[2]  M. Buehler,et al.  The Use of Piezoelectric Crystals as Electrode Substrates in Iron Corrosion Studies: The Real-Time, In Situ Determination of Dissolution and Film Formation Reaction Rates , 1986 .

[3]  M. Keddam,et al.  Kinetic study of electrode processes by ac quartz electrogravimetry , 1988 .

[4]  Matthew A Cooper,et al.  A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions , 2007, Journal of molecular recognition : JMR.

[5]  M. Keddam,et al.  Ac-Electrogravimetry Study of Electroactive Thin Films. II. Application to Polypyrrole , 2002 .

[6]  Stanley Bruckenstein,et al.  Experimental aspects of use of the quartz crystal microbalance in solution , 1985 .

[7]  Andrea Taroni,et al.  Improving the accuracy and operating range of quartz microbalance sensors by a purposely designed oscillator circuit , 2001, IEEE Trans. Instrum. Meas..

[8]  Roland E. Best Phase-locked loops : design, simulation, and applications , 2003 .

[9]  B. Piro,et al.  New frequency/voltage converters for ac-electrogravimetric measurements based on fast quartz crystal microbalance. , 2007, The Review of scientific instruments.

[10]  Dan H. Wolaver,et al.  Phase-Locked Loop Circuit Design , 1991 .

[11]  J. J. García-Jareño,et al.  EIS and Ac-Electrogravimetry Study of PB Films in KCl, NaCl, and CsCl Aqueous Solutions , 2003 .

[12]  A. Arnau,et al.  QCM Data Analysis and Interpretation , 2009 .

[13]  J. Cooper,et al.  All-Digital Interface ASIC for a QCM-Based Electronic Nose , 2004 .

[14]  H. Perrot,et al.  Influence of antibody insertion on the electrochemical behavior of polypyrrole films by using fast QCM measurements , 2003 .

[15]  Roberto M. Torresi,et al.  Técnicas in situ de baixo custo em eletroquímica: a microbalança a cristal de quartzo , 2000 .

[16]  H. Perrot,et al.  ac-Electrogravimetry study of an all solid state potassium selective electrode with polypyrrole as the solid internal contact , 2006 .

[17]  D. M. Soares,et al.  Interface Electronic Systems for AT-Cut QCM Sensors: A comprehensive review , 2009 .

[18]  Yolanda Jiménez,et al.  Circuit for continuous motional series resonant frequency and motional resistance monitoring of quartz crystal resonators by parallel capacitance compensation , 2002 .

[19]  A. A. Vives Piezoelectric transducers and applications , 2004 .

[20]  M. Keddam,et al.  a.c. electrogravimetry on conducting polymers. Application to polyaniline , 1999 .

[21]  E. Calvo,et al.  Combination of Quartz Crystal Microbalance with other Techniques , 2009 .

[22]  Carlos Alexander Grajales,et al.  UNA METODOLOGÍA PARA VALORAR UN CALLABLE BOND , 2008 .