Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results.

Computer-assisted surgery (CAS) systems improve alignment accuracy in total knee arthroplasty (TKA) but have not been widely implemented. Eighty knees underwent TKA using an accelerometer-based, portable navigation device (KneeAlign 2; OrthAlign Inc, Aliso Viejo, California), and the radiographic results were compared with 80 knees performed using a large-console, imageless CAS system (AchieveCAS; Smith and Nephew, Memphis, Tennessee). In the KneeAlign 2 cohort, 92.5% of patients had an alignment within 3° of a neutral mechanical axis (vs 86.3% with AchieveCAS, P < .01), 96.2% had a tibial component alignment within 2° of perpendicular to tibial mechanical axis (vs 97.5% with AchieveCAS, P = .8), and 94.9% had a femoral component alignment within 2° of perpendicular to the femoral mechanical axis (vs 92.5% with AchieveCAS, P < .01). The mean tourniquet time in the KneeAlign 2 cohort was 48.1 ± 10.2 minutes vs 54.1 ± 10.5 minutes in the AchieveCAS cohort (P < .01). Accelerometer-based, portable navigation is as accurate as large-console, imageless CAS systems in TKA.

[1]  E. Cáceres,et al.  Computer-assisted surgery can reduce blood loss after total knee arthroplasty , 2009, Knee Surgery, Sports Traumatology, Arthroscopy.

[2]  B. Munro Statistical methods for health care research , 1986 .

[3]  A. Çil,et al.  Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study. , 2007, The Journal of arthroplasty.

[4]  S. Jerabek,et al.  Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty. , 2011, Orthopedics.

[5]  Daniel J Berry,et al.  Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. , 2010, The Journal of bone and joint surgery. American volume.

[6]  M. Ritter,et al.  Tibial Component Failure Mechanisms in Total Knee Arthroplasty , 2004, Clinical orthopaedics and related research.

[7]  K. Buehler,et al.  Computer assisted navigation in total knee arthroplasty: comparison with conventional methods. , 2005, The Journal of arthroplasty.

[8]  Denis Nam,et al.  Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty. , 2011, The Journal of arthroplasty.

[9]  K. Mak,et al.  Comparison of Total Knee Arthroplasty Using Computer-Assisted Navigation versus Conventional Guiding Systems: A Prospective Study , 2009, Journal of orthopaedic surgery.

[10]  D. König,et al.  The effect of computer navigation on blood loss and transfusion rate in TKA. , 2010, Orthopedics.

[11]  S. Canale,et al.  Campbell's operative orthopaedics , 1987 .

[12]  T. Fehring,et al.  Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. , 2007, The Journal of arthroplasty.

[13]  P. Sharkey,et al.  Why Are Total Knee Arthroplasties Failing Today? , 2002 .

[14]  D. Dennis,et al.  Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. , 1993, The Journal of arthroplasty.

[15]  A Leardini,et al.  Alignments and Clinical Results in Conventional and Navigated Total Knee Arthroplasty , 2006, Clinical orthopaedics and related research.

[16]  N. Confalonieri,et al.  Computer-assisted technique versus intramedullary and extramedullary alignment systems in total knee replacement: a radiological comparison. , 2005, Acta orthopaedica Belgica.

[17]  F. Picard,et al.  Blood loss following total knee replacement in the morbidly obese: Effects of computer navigation. , 2011, The Knee.

[18]  Steven Kurtz,et al.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. , 2005, The Journal of bone and joint surgery. American volume.

[19]  M. Ritter,et al.  The effect of alignment and BMI on failure of total knee replacement. , 2011, The Journal of bone and joint surgery. American volume.

[20]  J. Harrison,et al.  Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. , 2003, The Journal of bone and joint surgery. British volume.

[21]  Sivashankar Chandrasekaran,et al.  Minimally invasive imageless computer-navigated knee surgery: initial results. , 2008, The Journal of arthroplasty.

[22]  Computer-assisted alignment system for tibial component placement in total knee replacement: a radiological study , 2008, La Chirurgia degli organi di movimento.

[23]  L. Dorr,et al.  Fat emboli in bilateral total knee arthroplasty. Predictive factors for neurologic manifestations. , 1989, Clinical orthopaedics and related research.

[24]  J. Sher,et al.  Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. , 2002, The Journal of bone and joint surgery. British volume.