Recent advances in epidemiology and prevention of gastrointestinal endoscopy related infections

Purpose of review This article reviews recent publications relevant to endoscope reprocessing and the potential for transmission of infection during gastrointestinal endoscopy. Recent findings There have been a number of established reprocessing failures of gastrointestinal endoscopes at various healthcare facilities across the US resulting in patient notifications. These episodes have been associated with user errors and reprocessing equipment failures, highlighting the need for increased compliance with established guidelines. Surveillance cultures may be useful to monitor the outcome of reprocessing, although their use is controversial. New technology to allow point-of-use monitoring is promising. Biofilm accumulation may be an issue when reprocessing gastrointestinal endoscopes. Although peracetic acid has been promoted as superior to aldehyde-type liquid chemical germicides with regard to soil fixation, it may only be a modest improvement. Electrolyzed acid water is an emerging liquid chemical germicide that may be equivalent to currently accepted disinfectants. There appears to be no benefit to an additional reprocessing cycle before use for endoscopes that have been appropriately cleaned, disinfected, and stored. Summary With the recent media attention on gastrointestinal endoscope reprocessing failures, despite the absence of documented transmission of infection, increased compliance with existing guidelines and new initiatives to enhance endoscope reprocessing are increasingly important to maintain public confidence.

[1]  Y. Cossart,et al.  Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? , 2004, The Journal of hospital infection.

[2]  A. Jemal,et al.  Cancer Statistics, 2004 , 2004, CA: a cancer journal for clinicians.

[3]  F. Moses,et al.  Current GI Endoscope Disinfection and QA Practices , 2004, Digestive Diseases and Sciences.

[4]  C. Sciortino,et al.  Assessment of a Novel Approach to Evaluate the Outcome of Endoscope Reprocessing , 2004, Infection Control & Hospital Epidemiology.

[5]  N. Dubrawsky Cancer statistics , 1989, CA: a cancer journal for clinicians.

[6]  S. Paik,et al.  Efficacy of electrolyzed acid water in reprocessing patient‐used flexible upper endoscopes: Comparison with 2% alkaline glutaraldehyde , 2004, Journal of gastroenterology and hepatology.

[7]  W. Rutala,et al.  Draft Guideline for Disinfection and Sterilization in Healthcare Facilities , 2002 .

[8]  P. Burge,et al.  Occupational asthma due to glutaraldehyde and formaldehyde in endoscopy and x ray departments. , 1995, Thorax.

[9]  Carol Petersen,et al.  Multi-society guideline for reprocessing flexible gastrointestinal endoscopes , 2003, Infection Control & Hospital Epidemiology.

[10]  Douglas B Nelson,et al.  Infectious disease complications of GI endoscopy: part II, exogenous infections. , 2003, Gastrointestinal endoscopy.

[11]  S. Rejchrt,et al.  Bacteriologic testing of endoscopes after high-level disinfection. , 2004, Gastrointestinal endoscopy.

[12]  C. Alvarado,et al.  Nosocomial infections from contaminated endoscopes: a flawed automated endoscope washer. An investigation using molecular epidemiology. , 1991, The American journal of medicine.

[13]  G. Kampf,et al.  Surface fixation of dried blood by glutaraldehyde and peracetic acid. , 2004, The Journal of hospital infection.

[14]  P. Collignon,et al.  How well are endoscopes cleaned and disinfected between patients? , 1990, The Medical journal of Australia.

[15]  David J. Weber,et al.  Disinfection and Sterilization In Healthcare Facilities , 2004 .

[16]  D. Nelson Newer technologies for endoscope disinfection: electrolyzed acid water and disposable-component endoscope systems. , 2000, Gastrointestinal endoscopy clinics of North America.

[17]  T. Koshikawa,et al.  Differential diagnosis of pancreatic cancer and focal pancreatitis by using EUS-guided FNA. , 2005, Gastrointestinal endoscopy.

[18]  J. Rey,et al.  Variant Creutzfeldt-Jakob Disease (vCJD) and Gastrointestinal Endoscopy , 2001, Endoscopy.

[19]  A. Dimarino,et al.  GI endoscopic reprocessing practices in the United States. , 1999, Gastrointestinal endoscopy.

[20]  E. Bsg Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee , 1998, Gut.

[21]  Yuko Sato,et al.  ENDOSCOPE CONTAMINATION FROM HBV‐ AND HCV‐POSITIVE PATIENTS AND EVALUATION OF A CLEANING/DISINFECTING METHOD USING STRONGLY ACIDIC ELECTROLYZED WATER , 2003 .

[22]  Y. Cossart,et al.  Removal of biofilm from endoscopes: evaluation of detergent efficiency. , 2004, American journal of infection control.

[23]  Persis Mehta,et al.  Disinfection of medical and surgical materials. , 1971, American journal of hospital pharmacy.

[24]  Recommended practices for cleaning and processing endoscopes and endoscope accessories. , 2003, AORN journal.

[25]  C. Beanland,et al.  Establishing the Shelf Life of Flexible Colonoscopes , 2002, Gastroenterology nursing : the official journal of the Society of Gastroenterology Nurses and Associates.

[26]  F. Moses,et al.  Surveillance Cultures to Monitor Quality of Gastrointestinal Endoscope Reprocessing , 2003, American Journal of Gastroenterology.

[27]  W A Rutala,et al.  APIC guideline for selection and use of disinfectants. , 1996, American journal of infection control.

[28]  R. Gun,et al.  Glutaraldehyde exposures and symptoms among endoscopy nurses in South Australia , 1997 .