Active Sensor for Microwave Tissue Imaging with Bias-Switched Arrays

A prototype of a bias-switched active sensor was developed and measured to establish the achievable dynamic range in a new generation of active arrays for microwave tissue imaging. The sensor integrates a printed slot antenna, a low-noise amplifier (LNA) and an active mixer in a single unit, which is sufficiently small to enable inter-sensor separation distance as small as 12 mm. The sensor’s input covers the bandwidth from 3 GHz to 7.5 GHz. Its output intermediate frequency (IF) is 30 MHz. The sensor is controlled by a simple bias-switching circuit, which switches ON and OFF the bias of the LNA and the mixer simultaneously. It was demonstrated experimentally that the dynamic range of the sensor, as determined by its ON and OFF states, is 109 dB and 118 dB at resolution bandwidths of 1 kHz and 100 Hz, respectively.

[1]  Natalia K. Nikolova,et al.  TEM Horn Antenna for Ultra-Wide Band Microwave Breast Imaging , 2009 .

[2]  J.C. Bolomey,et al.  Microwave imaging techniques for biomedical applications , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).

[3]  Jörg Maier,et al.  APPLICATION NOTE , 1997 .

[4]  Natalia K. Nikolova,et al.  Real-Time Microwave Imaging of a Compressed Breast Phantom With Planar Scanning , 2018, IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology.

[5]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries , 2007, Physics in medicine and biology.

[6]  P. J. Soh,et al.  Microwave imaging technique for lung tumour detection , 2016, 2016 German Microwave Conference (GeMiC).

[7]  N. Nikolova Microwave Imaging for Breast Cancer , 2011, IEEE Microwave Magazine.

[8]  A. Trehan,et al.  Physical phantoms for microwave imaging of the breast , 2012, 2012 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS).

[9]  Xia Xiao,et al.  A Compact 4 $\times$ 4 Planar UWB Antenna Array for 3-D Breast Cancer Detection , 2013, IEEE Antennas and Wireless Propagation Letters.

[10]  Jean-Charles Bolomey,et al.  Engineering applications of the modulated scatterer technique , 2001 .

[11]  Xiang Guan,et al.  A fully integrated 24-GHz eight-element phased-array receiver in silicon , 2004, IEEE Journal of Solid-State Circuits.

[12]  Natalia K. Nikolova,et al.  Switched sensor array for near-field microwave imaging of tissue , 2015, 2015 IEEE International Symposium on Antennas and Propagation & USNC/URSI National Radio Science Meeting.

[13]  Takamaro Kikkawa,et al.  Complex permittivities of breast tumor tissues obtained from cancer surgeries , 2014 .

[14]  Aastha Trehan NUMERICAL AND PHYSICAL MODELS FOR MICROWAVE BREAST IMAGING , 2009 .

[15]  Natalia K. Nikolova,et al.  Microwave Holography Using Point-Spread Functions Measured With Calibration Objects , 2015, IEEE Transactions on Instrumentation and Measurement.

[16]  G. Franceschetti,et al.  On the spatial bandwidth of scattered fields , 1987 .

[17]  J. Sachs,et al.  MNP enhanced microwave breast cancer imaging based on ultra-wideband pseudo-noise sensing , 2017, 2017 11th European Conference on Antennas and Propagation (EUCAP).

[18]  Lorenzo Crocco,et al.  On the Design of Phased Arrays for Medical Applications , 2016, Proceedings of the IEEE.

[19]  Natalia K. Nikolova,et al.  Modeling and design of a switched transceiver array for tissue imaging , 2015, 2015 IEEE MTT-S International Conference on Numerical Electromagnetic and Multiphysics Modeling and Optimization (NEMO).

[20]  John L. Volakis,et al.  A novel body-worn RF sensor for deep tissue imaging , 2015, 2015 IEEE MTT-S 2015 International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO).

[21]  Johan Jacob Mohr,et al.  An Introduction to Microwave Imaging for Breast Cancer Detection , 2016 .

[22]  Amin M. Abbosh,et al.  Lung cancer detection using frequency-domain microwave imaging , 2015 .

[23]  I. J. Craddock,et al.  Development and testing of a 60-element UWB conformal array for breast cancer imaging , 2011, Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP).

[24]  Nader Behdad,et al.  Multiband Miniaturized Patch Antennas for a Compact, Shielded Microwave Breast Imaging Array , 2014, IEEE Transactions on Antennas and Propagation.

[25]  Sima Noghanian,et al.  Introduction to Microwave Imaging , 2014 .

[26]  Seungjun Lee,et al.  Recent Advances in Microwave Imaging for Breast Cancer Detection , 2016, Int. J. Biomed. Imaging.

[27]  A. Preece,et al.  Radar-Based Breast Cancer Detection Using a Hemispherical Antenna Array—Experimental Results , 2009, IEEE Transactions on Antennas and Propagation.

[28]  N. Nikolova Microwave Biomedical Imaging , 2014 .

[29]  M. Popovic,et al.  Miniaturized microstrip-fed "Dark Eyes" antenna for near-field microwave sensing , 2005, IEEE Antennas and Wireless Propagation Letters.

[30]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[31]  R. Benjamin,et al.  A Comparison of a Wide-Slot and a Stacked Patch Antenna for the Purpose of Breast Cancer Detection , 2010, IEEE Transactions on Antennas and Propagation.

[32]  Robert C. Dixon Radio Receiver Design , 1946, Nature.

[33]  K. D. Paulsen,et al.  3D Microwave bone imaging , 2012, 2012 6th European Conference on Antennas and Propagation (EUCAP).

[34]  T. Vogl,et al.  Quality control of carbon-rubber tissue phantoms: Comparative MRI, CT, X-ray and UWB microwave measurements , 2017, 2017 11th European Conference on Antennas and Propagation (EUCAP).

[35]  Lorenzo Crocco,et al.  Experimental Framework for Magnetic Nanoparticles Enhanced Breast Cancer Microwave Imaging , 2017, IEEE Access.

[36]  T. Kikkawa,et al.  Detectability of Breast Tumor by a Hand-held Impulse-Radar Detector: Performance Evaluation and Pilot Clinical Study , 2017, Scientific Reports.

[37]  Amin M. Abbosh,et al.  Microwave imaging for brain stroke detection using Born iterative method , 2013 .

[38]  M. Ravan,et al.  Three-Dimensional Near-Field Microwave Holography Using Reflected and Transmitted Signals , 2011, IEEE Transactions on Antennas and Propagation.

[39]  Ryan J Halter,et al.  The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience , 2009, Physiological measurement.

[40]  S Kharkovsky,et al.  Modulated Elliptical Slot Antenna for Electric Field Mapping and Microwave Imaging , 2011, IEEE Transactions on Antennas and Propagation.

[41]  M. Okoniewski,et al.  Highly Accurate Debye Models for Normal and Malignant Breast Tissue Dielectric Properties at Microwave Frequencies , 2007, IEEE Microwave and Wireless Components Letters.

[43]  Semih Doğu,et al.  Feasibility of brain stroke imaging with microwaves , 2016, 2016 IEEE Asia-Pacific Conference on Applied Electromagnetics (APACE).

[44]  Francesca Rapetti,et al.  Numerical Modeling and High-Speed Parallel Computing: New Perspectives on Tomographic Microwave Imaging for Brain Stroke Detection and Monitoring. , 2017, IEEE Antennas and Propagation Magazine.

[45]  Tommaso Isernia,et al.  Electromagnetic inverse scattering: Retrievable information and measurement strategies , 1997 .