A System to Maintain Perceptually Linear Networked Display Devices

The CRT is commonly used to display digital medical image data. The brightness as a function of input signal is di erent for each CRT, is nonlinear and poorly matched to the human eye's perception of brightness change, decreases over time, and is easily changed with hardware contrast and brightness adjustments. Previous studies have suggested display brightness functions which are based on human visual experiments and which produce the same contrast perception for small display value changes at all brightness levels. The best scale depends on CRT luminance and scene dependent variables. We have developed an X Window based client server approach to maintain perceptually linear display scales using unique transformation tables for many display devices. Color use on X window systems is described. Perceptually linear human visual models are described. Finally we present a method to implement and maintain these models on a networked collection of X displays.

[1]  Peter G. J. Barten,et al.  Physical model for the contrast sensitivity of the human eye , 1992, Electronic Imaging.

[2]  Peter G. J. Barten,et al.  Spatiotemporal model for the contrast sensitivity of the human eye and its temporal aspects , 1993, Electronic Imaging.

[3]  Albert A. Michelson,et al.  Studies in Optics , 1995 .

[4]  Hans Roehrig,et al.  Noise of CRT display systems , 1993, Medical Imaging.

[5]  H. R. Blackwell,et al.  Contrast Threshold of the Human eye , 1946 .

[6]  Hartwig R. Blume,et al.  Presentation of medical images on CRT displays: a renewed proposal for a display function standard , 1993, Medical Imaging.

[7]  Bradley M. Hemminger,et al.  Perceptual linearization of video-display monitors for medical image presentation , 1994, Medical Imaging.

[8]  Hans Roehrig,et al.  Comparison of the physical performance of high-resolution CRT displays and films recorded by laser image printers and displayed on light-boxes and the need for a display standard , 1990, Medical Imaging.

[9]  Hans Roehrig,et al.  Optimizing the display function of display devices , 1992, Medical Imaging.

[10]  K. G. Lisk,et al.  Test pattern for video displays and hard-copy cameras. , 1985, Radiology.

[11]  M. Ibrahim Sezan,et al.  Uniform Perceptual Quantization: Applications to Digital Radiography , 1987, IEEE Transactions on Systems, Man, and Cybernetics.

[12]  E. Peli Contrast in complex images. , 1990, Journal of the Optical Society of America. A, Optics and image science.