Thermal Effects of Diagnostic Ultrasound in an Anthropomorphic Skull Model

Abstract Purpose: Exposure to diagnostic ultrasound (US) can significantly heat biological tissue although conventional routine examinations are regarded as safe. The risk of unwanted thermal effects increases with a high absorption coefficient and extended insonation time. Certain applications of transcranial diagnostic US (TC-US) require prolonged exposure. An anthropomorphic skull model (ASM) was developed to evaluate thermal effects induced by TC-US of different modalities. The objective was to determine whether prolonged continuous TC-US application results in potentially harmful temperature increases. Materials and Methods: The ASM consists of a human skull with tissue mimicking material and exhibits acoustic and anatomical characteristics of the human skull and brain. Experiments are performed with a diagnostic US device testing four different US modalities: Duplex PW (pulsed wave) Doppler, PW Doppler, color flow Doppler and B-mode. Temperature changes are recorded during 180 minutes of insonation. Results: All measurements revealed significant temperature increases during insonation independent of the US modality. The maximum temperature elevation of + 5.25° C (p < 0.001) was observed on the surface of the skull exposed to duplex PW Doppler. At the bone-brain border a maximum temperature increae of + 2.01 °C (p < 0.001) was noted. Temperature increases within the brain were < 1.23 °C (p = 0.001). The highest values were registered using the duplex PW Doppler modality. Conclusion: TC-US induces significant local heating effects in an ASM. An application duration that extends routine clinical periods causes potentially harmful heating especially in tissue close to bone. TC-US elevates the temperature in the brain mimicking tissue but is not capable of producing harmful temperature increases during routine examinations. However, the risk of thermal injury in brain tissue increases significantly after an exposure time of > 2 hours.

[1]  K. Jaeger Ultrasound has Fundamentally Transformed Vascular Medicine. , 2008, Ultraschall in der Medizin.

[2]  C. Nolte,et al.  Does Routine Transcranial Duplex Ultrasound Heat Up the Patient Brain? , 2008, Ultraschall in der Medizin.

[3]  A. Alexandrov,et al.  Ultrasound-enhanced thrombolysis: from bedside to bench. , 2008, Stroke.

[4]  I. König,et al.  Sonothrombolysis With Transcranial Color-Coded Sonography and Recombinant Tissue-Type Plasminogen Activator in Acute Middle Cerebral Artery Main Stem Occlusion: Results From a Randomized Study , 2008, Stroke.

[5]  J. Zachary,et al.  The Risk of Exposure to Diagnostic Ultrasound in Postnatal Subjects , 2008, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[6]  H. Furuhata,et al.  Does Long-Term Continuous Transcranial Doppler Monitoring Require a Pause for Safer Use? , 2007, Cerebrovascular Diseases.

[7]  M. Hennerici,et al.  Brain Temperature During 340-kHz Pulsed Ultrasound Insonation: A Safety Study for Sonothrombolysis , 2006, Stroke.

[8]  Achim Gass,et al.  Transcranial Low-Frequency Ultrasound-Mediated Thrombolysis in Brain Ischemia: Increased Risk of Hemorrhage With Combined Ultrasound and Tissue Plasminogen Activator Results of a Phase II Clinical Trial , 2005, Stroke.

[9]  A. Alexandrov,et al.  Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke. , 2004, The New England journal of medicine.

[10]  P. J. Hoopes,et al.  Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia , 2003, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  C. Koch [Thermal effects of ultrasound]. , 2001, Ultraschall in der Medizin.

[12]  S. Weber,et al.  Transcranial Color-coded Sonography (TCCS): A Helpful Tool In Clinical Neurology , 2000 .

[13]  A. J. McPhee,et al.  The influence of variations in blood flow on pulsed doppler ultrasonic heating of the cerebral cortex of the neonatal pig. , 2000, Ultrasound in medicine & biology.

[14]  M. Edwards,et al.  Ultrasound-induced temperature increase in guinea-pig fetal brain in utero: third-trimester gestation. , 1998, Ultrasound in medicine & biology.

[15]  M. Edwards,et al.  Ultrasound-induced temperature increase in the guinea-pig fetal brain in vitro. , 1998, Ultrasound in medicine & biology.

[16]  R. Busto,et al.  Combating hyperthermia in acute stroke: a significant clinical concern. , 1998, Stroke.

[17]  K V Ramnarine,et al.  Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories. , 1998, Ultrasonics.

[18]  W. Dalton Dietrich,et al.  Small Differences in Intraischemic Brain Temperature Critically Determine the Extent of Ischemic Neuronal Injury , 1987, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[19]  S D Prionas,et al.  The effects of hyperthermia on normal mesenchymal tissues. Application of a histologic grading system. , 1983, Archives of pathology & laboratory medicine.

[20]  A M STOLL,et al.  Relationship between pain and tissue damage due to thermal radiation. , 1959, Journal of applied physiology.

[21]  Gerald Maurer,et al.  Ultrasound thrombolysis , 2005, Thrombosis and Haemostasis.

[22]  R. Bezemer,et al.  On the development of a method to measure the surface temperature of ultrasonic diagnostic transducers , 2004 .

[23]  R. Bezemer,et al.  [A test object for quality control of the instrument for doppler (duplex) ultrasonography, based on the Draft IEC 61685 Standard]. , 1999, Ultraschall in der Medizin.

[24]  R. Busto,et al.  Brain damage and temperature: cellular and molecular mechanisms. , 1996, Advances in neurology.

[25]  J. Wu,et al.  Temperature rise generated by diagnostic ultrasound in a transcranial phantom. , 1995, Ultrasound in medicine & biology.

[26]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .