Diffusion spectrum MRI using body-centered-cubic and half-sphere sampling schemes

The optimum sequence parameters of diffusion spectrum MRI (DSI) on clinical scanners were investigated previously. However, the scan time of approximately 30 min is still too long for patient studies. Additionally, relatively large sampling interval in the diffusion-encoding space may cause aliasing artifact in the probability density function when Fourier transform is undertaken, leading to estimation error in fiber orientations. Therefore, this study proposed a non-Cartesian sampling scheme, body-centered-cubic (BCC), to avoid the aliasing artifact as compared to the conventional Cartesian grid sampling scheme (GRID). Furthermore, the accuracy of DSI with the use of half-sphere sampling schemes, i.e. GRID102 and BCC91, was investigated by comparing to their full-sphere sampling schemes, GRID203 and BCC181, respectively. In results, smaller deviation angle and lower angular dispersion were obtained by using the BCC sampling scheme. The half-sphere sampling schemes yielded angular precision and accuracy comparable to the full-sphere sampling schemes. The optimum b(max) was approximately 4750 s/mm(2) for GRID and 4500 s/mm(2) for BCC. In conclusion, the BCC sampling scheme could be implemented as a useful alternative to the GRID sampling scheme. Combination of BCC and half-sphere sampling schemes, that is BCC91, may potentially reduce the scan time of DSI from 30 min to approximately 14 min while maintaining its precision and accuracy.

[1]  K. Trinkaus,et al.  Quantification of increased cellularity during inflammatory demyelination. , 2011, Brain : a journal of neurology.

[2]  Jerry L. Prince,et al.  Resolution of crossing fibers with constrained compressed sensing using diffusion tensor MRI , 2012, NeuroImage.

[3]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[4]  P. Hagmann,et al.  Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[5]  Chun-Hung Yeh,et al.  Reduced Encoding Diffusion Spectrum Imaging Implemented With a Bi-Gaussian Model , 2008, IEEE Transactions on Medical Imaging.

[6]  O. Sporns,et al.  Mapping the Structural Core of Human Cerebral Cortex , 2008, PLoS biology.

[7]  Ken E Sakaie,et al.  Quantitative assessment of motion correction for high angular resolution diffusion imaging. , 2010, Magnetic resonance imaging.

[8]  Li-Wei Kuo,et al.  Mossy fiber sprouting in pilocarpine-induced status epilepticus rat hippocampus: A correlative study of diffusion spectrum imaging and histology , 2008, NeuroImage.

[9]  V. Wedeen,et al.  Diffusion MRI of Complex Neural Architecture , 2003, Neuron.

[10]  Norbert Schuff,et al.  Improved diffusion imaging through SNR‐enhancing joint reconstruction , 2013, Magnetic resonance in medicine.

[11]  D. Javitt,et al.  MRI study of white matter diffusion anisotropy in schizophrenia , 2003, Neuroreport.

[12]  N. Makris,et al.  High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity , 2002, Magnetic resonance in medicine.

[13]  Chun-Hung Yeh,et al.  Resolving crossing fibres using constrained spherical deconvolution: Validation using diffusion-weighted imaging phantom data , 2008, NeuroImage.

[14]  Fang-Cheng Yeh,et al.  Generalized ${ q}$-Sampling Imaging , 2010, IEEE Transactions on Medical Imaging.

[15]  Li-Wei Kuo,et al.  Optimization of diffusion spectrum imaging and q-ball imaging on clinical MRI system , 2008, NeuroImage.

[16]  C. Hardy,et al.  Accelerated diffusion spectrum imaging in the human brain using compressed sensing , 2011, Magnetic resonance in medicine.

[17]  Ching Yao,et al.  Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms , 2003, NeuroImage.

[18]  Eduard Gröller,et al.  Optimal regular volume sampling , 2001, Proceedings Visualization, 2001. VIS '01..

[19]  C.P. Lin,et al.  Reduced encoding of diffusion spectrum imaging with cross-term correction , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..

[20]  O. Sporns,et al.  White matter maturation reshapes structural connectivity in the late developing human brain , 2010, Proceedings of the National Academy of Sciences.

[21]  James P. Schaffer,et al.  The Science and Design of Engineering Materials , 1995 .

[22]  Yogesh Rathi,et al.  Spatially Regularized Compressed Sensing for High Angular Resolution Diffusion Imaging , 2011, IEEE Transactions on Medical Imaging.

[23]  Stefan Skare,et al.  Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise , 2007, Magnetic resonance in medicine.

[24]  Li-Wei Kuo,et al.  The microstructural integrity of the corpus callosum and associated impulsivity in alcohol dependence: A tractography-based segmentation study using diffusion spectrum imaging , 2010, Psychiatry Research: Neuroimaging.

[25]  R. Meuli,et al.  Diffusion Spectrum Imaging Shows the Structural Basis of Functional Cerebellar Circuits in the Human Cerebellum In Vivo , 2009, PloS one.

[26]  M. Catani Diffusion tensor magnetic resonance imaging tractography in cognitive disorders , 2006, Current opinion in neurology.

[27]  P. Callaghan Principles of Nuclear Magnetic Resonance Microscopy , 1991 .

[28]  Sophia Frangou,et al.  Recent diffusion tensor imaging findings in early stages of schizophrenia , 2009, Current opinion in psychiatry.

[29]  Erick Jorge Canales-Rodríguez,et al.  Mathematical description of q‐space in spherical coordinates: Exact q‐ball imaging , 2009, Magnetic resonance in medicine.

[30]  Dan E. Dudgeon,et al.  Multidimensional Digital Signal Processing , 1983 .

[31]  Jeremy D. Schmahmann,et al.  Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers , 2008, NeuroImage.

[32]  V. Wedeen,et al.  Simultaneous echo refocusing in EPI , 2002, Magnetic resonance in medicine.

[33]  Wang Zhan,et al.  In-vivo investigation of the human cingulum bundle using the optimization of MR diffusion spectrum imaging. , 2010, European journal of radiology.

[34]  O Sporns,et al.  Predicting human resting-state functional connectivity from structural connectivity , 2009, Proceedings of the National Academy of Sciences.

[35]  Z-A Luo,et al.  Tract-Specific and Region of Interest Analysis of Corticospinal Tract Integrity in Subcortical Ischemic Stroke: Reliability and Correlation with Motor Function of Affected Lower Extremity , 2010, American Journal of Neuroradiology.

[36]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[37]  Fang-Cheng Yeh,et al.  Estimation of fiber orientation and spin density distribution by diffusion deconvolution , 2011, NeuroImage.

[38]  Yao Wang,et al.  Video Processing and Communications , 2001 .