Origin of product ions in the MS/MS spectra of peptides in a quadrupole ion trap

Stored waveform inverse Fourier transform and double resonance techniques have been used in conjunction with a quadrupole ion trap to study the dissociation patterns of peptide ions. These experiments provide insight into the origin of individual product ions in an MS/MS spectrum. Results show for a series of leucine enkephalin analogues with five amino acid residues that the b4 ion is the main product ion through which many other product ions arise. It was also observed that the percentage of the a4 product ions that are formed directly from the protonated molecule (M+H)+ depends on the nature of the fourth amino acid residue. In addition, it was determined that in the peptides studied here lower series b ions (e.g., b3 arise from direct dissociation of higher series b ions (e.g., b4 only about 50% of the time.

[1]  A. G. Harrison,et al.  Pathways to Immonium Ions in the Fragmentation of Protonated Peptides , 1997 .

[2]  M. Gross,et al.  Consecutive reactions in triple analyzer mass spectrometry and applications to mixture analysis , 1982 .

[3]  Stephen A. Martin,et al.  Mass spectrometric determination of the amino acid sequence of peptides and proteins , 1987 .

[4]  L. Deterding,et al.  Consecutive reaction monitoring in a four-sector mass spectrometer: MS4 and one step beyond. , 1988, Analytical chemistry.

[5]  A. Marshall,et al.  Tailored excitation for Fourier transform ion cyclotron mass spectrometry , 1985 .

[6]  M. Baldwin,et al.  Factors affecting immonium ion intensities in the high‐energy collision‐induced decomposition spectra of peptides , 1991 .

[7]  I. Csizmadia,et al.  The structure and fragmentation of Bn (n≥3) ions in peptide spectra , 1996, Journal of the American Society for Mass Spectrometry.

[8]  R. Cooks,et al.  Observation of sequence‐specific peptide fragmentation using extended tandem mass spectrometry experiments , 1989 .

[9]  R. Cooks,et al.  A penta-quadrupole instrument for reaction intermediate scans and other MS-MS-MS experiments , 1990 .

[10]  G. Glish,et al.  Effects of heavy gases on the tandem mass spectra of peptide ions in the quadrupole ion trap , 1996, Journal of the American Society for Mass Spectrometry.

[11]  R. Cotter,et al.  Advanced stored waveform inverse Fourier transform technique for a matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometer. , 1996, Rapid communications in mass spectrometry : RCM.

[12]  M. Karas,et al.  Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. , 1988, Analytical chemistry.

[13]  J. Brodbelt,et al.  Use of infrared multiphoton photodissociation with SWIFT for electrospray ionization and laser desorption applications in a quadrupole ion trap mass spectrometer. , 1996, Analytical chemistry.

[14]  K. Tomer,et al.  Delayed dissociation spectra of survivor ions from high-energy collisional activation , 1993, Journal of the American Society for Mass Spectrometry.

[15]  R. Cooks,et al.  Selective Injection and Isolation of Ions in Quadrupole Ion Trap Mass Spectrometry Using Notched Waveforms Created Using the Inverse Fourier Transform , 1994 .

[16]  I. Csizmadia,et al.  Why Are B ions stable species in peptide spectra? , 1995, Journal of the American Society for Mass Spectrometry.

[17]  S. Gaskell,et al.  Sequential mass spectrometry applied to the study of the formation of , 1991 .

[18]  F. McLafferty Tandem mass spectrometry. , 1981, Science.

[19]  Jim X. Shen,et al.  Reactions of Hydantoin and Succinimide Anticonvulsants with Dimethyl Ether Ions in a Quadrupole Ion Trap Mass Spectrometer , 1996 .

[20]  I. Papayannopoulos,et al.  The interpretation of collision‐induced dissociation tandem mass spectra of peptides , 1996 .

[21]  M. F. Bean,et al.  Integration of mass spectrometry in analytical biotechnology. , 1991, Analytical chemistry.

[22]  S. Gaskell,et al.  Elucidation of some fragmentations of small peptides using sequential mass spectrometry on a hybrid instrument. , 1989, Rapid communications in mass spectrometry : RCM.

[23]  G. Glish,et al.  Mass spectrometry/mass spectrometry: techniques and applications of tandem mass spectrometry , 1990 .

[24]  J R Yates,et al.  Protein sequencing by tandem mass spectrometry. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[25]  Michael Barber,et al.  Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry , 1981 .

[26]  P. Schnier,et al.  Dissociation energetics and mechanisms of leucine enkephalin (M+H)+ and (2M+X)+ ions (X=H, Li, Na, K, and Rb) measured by blackbody infrared radiative dissociation , 1997, Journal of the American Society for Mass Spectrometry.

[27]  R. Cooks,et al.  A versatile method of simulation of the operation of ion trap mass spectrometers , 1992 .

[28]  R. Cooks,et al.  Broad-band excitation in the quadrupole ion trap mass spectrometer using shaped pulses created with the inverse Fourier transform , 1993 .

[29]  M. Mann,et al.  Electrospray ionization for mass spectrometry of large biomolecules. , 1989, Science.