Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch open

To analyse influences under various fault conditions, a fault model of an inverter-fed permanent magnet (PM) synchronous motor drive that can be used for a performance assessment of a diagnostic algorithm is presented. For fault conditions of a drive system, a short-circuited turn in the stator winding, switching device open in pulse width modulated inverter and the isolation between the inverter and motor are considered. Even though the conventional dq model is widely used to control an AC motor, it cannot be used directly for the analysis of a motor fault, since three-phase balanced condition does not hold under such conditions, and thus, it is not easy to obtain phase voltage inputs of motor from the pole voltage. To overcome this limitation, a fault model of an inverter-fed PM synchronous motor is derived using the line voltage, which can be effectively used to evaluate the performance of a fault detection algorithm. A test motor producing short-circuited turn in the stator winding is built. The validity of the proposed fault model is verified through the comparative simulations and experiments using digital signal processor TMS320F28335 under various fault conditions.

[1]  S. Gopalakrishnan,et al.  Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform , 2006, IEEE Transactions on Energy Conversion.

[2]  R. Spee,et al.  Remedial strategies for brushless DC drive failures , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[3]  Gojko Joksimovic,et al.  The detection of inter-turn short circuits in the stator windings of operating motors , 2000, IEEE Trans. Ind. Electron..

[4]  Thomas G. Habetler,et al.  Stator winding turn-fault detection for closed-loop induction motor drives , 2002 .

[5]  Dong-Choon Lee,et al.  Fault diagnosis of three-phase PWM inverters using wavelet and SVM , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[6]  D. K. Perovic,et al.  Online stator fault diagnosis in induction motors , 2001 .

[7]  Fiorenzo Filippetti,et al.  Recent developments of induction motor drives fault diagnosis using AI techniques , 2000, IEEE Trans. Ind. Electron..

[8]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[9]  S. Gopalakrishnan,et al.  A neuro-fuzzy approach to automatic diagnosis and location of stator inter-turn faults in CSI-fed PM brushless DC motors , 2005, IEEE Transactions on Energy Conversion.

[10]  T.A. Lipo,et al.  Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations , 2003, IEEE Transactions on Power Electronics.

[11]  Makarand Sudhakar Ballal,et al.  Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques , 2008 .

[12]  Silverio Bolognani,et al.  Experimental fault-tolerant control of a PMSM drive , 2000, IEEE Trans. Ind. Electron..

[13]  Bimal K. Bose,et al.  Investigation of fault modes of voltage-fed inverter system for induction motor drive , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[14]  H. G. Sedding,et al.  Current monitoring for detecting inter-turn short circuits in induction motors , 2001 .