Double-setting alpha-tricalcium phosphate cement provided with interconection channels in rabbits after enucleation : A potential implant for the anophthalmic socket

The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alphatricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits’ orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.

[1]  H. Meyer-Rüsenberg,et al.  [Porous orbital implants]. , 2014, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[2]  D. Garcia,et al.  Tissue Ingrowth Into Perforated Polymethylmethacrylate Orbital Implants: An Experimental Study , 2013, Ophthalmic plastic and reconstructive surgery.

[3]  G. Li,et al.  The Psychosocial Benefits of Secondary Hydroxyapatite Orbital Implant Insertion and Prosthesis Wearing for Patients With Anophthalmia , 2012, Ophthalmic plastic and reconstructive surgery.

[4]  Edgar Dutra Zanotto,et al.  Biocompatibility Analysis of Bioglass® 45S5 and Biosilicate® Implants in the Rabbit Eviscerated Socket , 2012, Orbit.

[5]  P. Toft,et al.  One‐stage explant–implant procedure of exposed porous orbital implants , 2012, Acta ophthalmologica.

[6]  M. Kanamura Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho , 2011 .

[7]  K. Ueki,et al.  Use of self-setting α-tricalcium phosphate for maxillary sinus augmentation in rabbit. , 2011, Clinical oral implants research.

[8]  Yahya Baba,et al.  Enucleation , 2010, Radiopaedia.org.

[9]  Liciane Sabadin Bertol,et al.  Projeto, fabricação e avaliação de implantes craniofaciais personalizados : proposta de utilização de materiais combinados , 2010 .

[10]  Kimimitsu Oda,et al.  Histological evaluation on bone regeneration of dental implant placement sites grafted with a self‐setting α‐tricalcium phosphate cement , 2008, Microscopy research and technique.

[11]  J. Laus,et al.  Evaluation of a Double-Setting &agr;-Tricalcium Phosphate Cement in Eviscerated Rabbit Eyes , 2006, Ophthalmic plastic and reconstructive surgery.

[12]  M. K. Sinha,et al.  Synthetic hydroxyapatite-based integrated orbital implants: a human pilot trial. , 2005, Indian journal of ophthalmology.

[13]  C. Luu,et al.  Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients. , 2004, Annals of the Academy of Medicine, Singapore.

[14]  D. Holck,et al.  Use of Bioglass for Orbital Volume Augmentation in Enophthalmos: A Rabbit Model (Oryctolagus Cuniculus) , 2003, Ophthalmic plastic and reconstructive surgery.

[15]  S. Kaltreider,et al.  Orbital implants in enucleation surgery: a report by the American Academy of Ophthalmology. , 2003, Ophthalmology.

[16]  L. Mawn,et al.  The Bioceramic Orbital Implant: Experience With 107 Implants , 2003, Ophthalmic plastic and reconstructive surgery.

[17]  L. Mawn,et al.  Investigation of a Bioresorbable Orbital Implant , 2002, Ophthalmic plastic and reconstructive surgery.

[18]  Luis Alberto De Oliveira Santos,et al.  Desenvolvimento de cimento de fosfato de calcio reforçado por fibras para uso na area medico-odontologica , 2002 .

[19]  L. Mawn,et al.  Brazilian Hydroxyapatite Implant , 2000, Ophthalmic plastic and reconstructive surgery.

[20]  J. O'Brien,et al.  Intraorbital implants after enucleation and their complications: a 10-year review. , 1998, Archives of ophthalmology.

[21]  J. Bilyk,et al.  Comparison of Fibrovascular Ingrowth into Hydroxyapatite and Porous Polyethylene Orbital Implants , 1994, Ophthalmic plastic and reconstructive surgery.

[22]  A. Molteno,et al.  "Physiological" orbital implant. , 1973, The British journal of ophthalmology.