Simultaneous Robust Coordinated Damping Control of Power System Stabilizers (PSSs), Static Var Compensator (SVC) and Doubly-Fed Induction Generator Power Oscillation Dampers (DFIG PODs) in Multimachine Power Systems

The potential of utilizing doubly-fed induction generator (DFIG)-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of a DFIG power oscillation damper (POD) with other damping controllers is rarely involved. A simultaneous robust coordinated multiple damping controller design strategy for a power system incorporating power system stabilizer (PSS), static var compensator (SVC) POD and DFIG POD is presented in this paper. This coordinated damping control design strategy is addressed as an eigenvalue-based optimization problem to increase the damping ratios of oscillation modes. Both local and inter-area electromechanical oscillation modes are intended in the optimization design process. Wide-area phasor measurement unit (PMU) signals, selected by the joint modal controllability/ observability index, are utilized as SVC and DFIG POD feedback modulation signals to suppress inter-area oscillation modes. The robustness of the proposed coordinated design strategy is achieved by simultaneously considering multiple power flow situations and operating conditions. The recently proposed Grey Wolf optimizer (GWO) algorithm is adopted to efficiently optimize the parameter values of multiple damping controllers. The feasibility and effectiveness of the proposed coordinated design strategy are demonstrated through frequency-domain eigenvalue analysis and nonlinear time-domain simulation studies in two modified benchmark test systems. Moreover, the dynamic response simulation results also validate the robustness of the recommended coordinated multiple damping controllers under various system operating conditions.

[1]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[2]  J. G. Slootweg,et al.  The impact of large scale wind power generation on power system oscillations , 2003 .

[3]  E. Larsen,et al.  Applying Power System Stabilizers Part I: General Concepts , 1981, IEEE Transactions on Power Apparatus and Systems.

[4]  Xiangning Lin,et al.  A Novel DFIG Damping Control for Power System with High Wind Power Penetration , 2016 .

[5]  O. Anaya-Lara,et al.  A power system stabilizer for DFIG-based wind generation , 2006, IEEE Transactions on Power Systems.

[6]  Andrew Keane,et al.  Identification of Critical Wind Farm Locations for Improved Stability and System Planning , 2013, IEEE Transactions on Power Systems.

[7]  S. C. Srivastava,et al.  Robust Wide-Area TS Fuzzy Output Feedback Controller for Enhancement of Stability in Multimachine Power System , 2012, IEEE Systems Journal.

[8]  Andrew Lewis,et al.  Grey Wolf Optimizer , 2014, Adv. Eng. Softw..

[9]  M. A. Abido,et al.  Robust tuning of power system stabilizers in multimachine power systems , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[10]  Xiao-Ping Zhang,et al.  Flexible AC Transmission Systems: Modelling and Control , 2006 .

[11]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[12]  Jing Ma,et al.  Application of Dual Youla Parameterization Based Adaptive Wide-Area Damping Control for Power System Oscillations , 2014, IEEE Transactions on Power Systems.

[13]  Jizhen Liu,et al.  Multi-Polytope-Based Adaptive Robust Damping Control in Power Systems Using CART , 2015, IEEE Transactions on Power Systems.

[14]  Yilu Liu,et al.  Frequency Regulation and Oscillation Damping Contributions of Variable-Speed Wind Generators in the U.S. Eastern Interconnection (EI) , 2015, IEEE Transactions on Sustainable Energy.

[15]  Ramakrishna Gokaraju,et al.  An Add-On Self-Tuning Control System for a UPFC Application , 2014, IEEE Transactions on Industrial Electronics.

[16]  Bikash C. Pal,et al.  Selection of feedback signals for controlling dynamics in future power transmission networks , 2015 .

[17]  I. Kamwa,et al.  Assessment of Two Methods to Select Wide-Area Signals for Power System Damping Control , 2008, IEEE Transactions on Power Systems.

[18]  Joe H. Chow,et al.  Concepts for design of FACTS controllers to damp power swings , 1995 .

[19]  Md. Apel Mahmud,et al.  Investigation of the Impacts of Large-Scale Wind Power Penetration on the Angle and Voltage Stability of Power Systems , 2012, IEEE Systems Journal.

[20]  Issarachai Ngamroo,et al.  Coordinated Robust Control of DFIG Wind Turbine and PSS for Stabilization of Power Oscillations Considering System Uncertainties , 2014, IEEE Transactions on Sustainable Energy.

[21]  A. Gomez-Exposito,et al.  Hierarchical Wide-Area Control of Power Systems Including Wind Farms and FACTS for Short-Term Frequency Regulation , 2012, IEEE Transactions on Power Systems.

[22]  R. Majumder,et al.  Design and real-time implementation of robust FACTS controller for damping inter-area oscillation , 2006, IEEE Transactions on Power Systems.

[23]  Andreas Sumper,et al.  Power oscillation damping supported by wind power: A review , 2012 .

[24]  Lucy Y. Pao,et al.  Control of wind turbines: Past, present, and future , 2009, 2009 American Control Conference.

[25]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[26]  Gerard Ledwich,et al.  An investigation on interarea mode oscillations of interconnected power systems with integrated wind farms , 2016 .

[27]  B. Pal,et al.  Robust Control in Power Systems , 2005 .

[28]  Bikash C. Pal,et al.  Electrical Oscillations in Wind Farm Systems: Analysis and Insight Based on Detailed Modeling , 2016, IEEE Transactions on Sustainable Energy.

[29]  Mohit Singh,et al.  Interarea Oscillation Damping Controls for Wind Power Plants , 2015, IEEE Transactions on Sustainable Energy.

[30]  Yijia CAO,et al.  Sequential design and global optimization of local power system stabilizer and wide-area HVDC stabilizing controller , 2016 .

[31]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[32]  Lingling Fan,et al.  Control of DFIG-Based Wind Generation to Improve Interarea Oscillation Damping , 2009, IEEE Transactions on Energy Conversion.

[33]  Kjetil Uhlen,et al.  Large‐scale wind power integration in Norway and impact on damping in the Nordic grid , 2005 .

[34]  S. Mishra,et al.  Improving Stability of a DFIG-Based Wind Power System With Tuned Damping Controller , 2009, IEEE Transactions on Energy Conversion.

[35]  Huiyong Li,et al.  Research on a Small Signal Stability Region Boundary Model of the Interconnected Power System with Large-Scale Wind Power , 2015 .

[36]  F. Milano,et al.  An open source power system analysis toolbox , 2005, 2006 IEEE Power Engineering Society General Meeting.

[37]  Istvan Erlich,et al.  Variable Speed Wind Turbines Based on Electromechanical Differential Systems , 2014, IEEE Transactions on Energy Conversion.

[38]  Innocent Kamwa,et al.  Wide-area measurement based stabilizing control of large power systems-a decentralized/hierarchical approach , 2001 .

[39]  B.M. Nomikos,et al.  Contribution of Doubly Fed Wind Generators to Oscillation Damping , 2009, IEEE Transactions on Energy Conversion.

[40]  Mohamed Zribi,et al.  Feedback Linearization Controller for a Wind Energy Power System , 2016 .

[41]  I. Kamwa,et al.  Control loops selection to damp inter-area oscillations of electrical networks , 2002 .

[42]  P. Kundur,et al.  Power system stability and control , 1994 .

[43]  M. A. Abido,et al.  Optimal power flow using particle swarm optimization , 2002 .