Semi-automatic Catheter Reconstruction from Two Views

We propose novel methods for (a) detection of a catheter in fluoroscopic images and (b) reconstruction of this catheter from two views. The novelty of (a) is a reduced user interaction and a higher accuracy. It requires only a single seed point on the catheter in the fluoroscopic image. Using this starting point, possible parts of the catheter are detected using a graph search. An evaluation of the detection using 66 clinical fluoroscopic images yielded an average error of 0.7 mm +/- 2.0 mm. The novelty of (b) is a better ability to deal with highly curved objects as it selects an optimal set of point correspondences from two point sequences describing the catheters in two fluoroscopic images. The selected correspondences are then used for computation of the 3-D reconstruction. The evaluation on 33 clinical biplane images yielded an average backprojection error of 0.4 mm +/- 0.6 mm.

[1]  H. Heidbüchel,et al.  Ablation of Focally Induced Atrial Fibrillation: , 2004, Journal of cardiovascular electrophysiology.

[2]  L. Nicolai A perspective on the requirements and design for advanced cruise missiles , 1979 .

[3]  Hüseyin Tek,et al.  Robust Vessel Tree Modeling , 2008, MICCAI.

[4]  Gabor Fichtinger,et al.  Medical Image Computing and Computer-Assisted Intervention - MICCAI 2008, 11th International Conference, New York, NY, USA, September 6-10, 2008, Proceedings, Part I , 2008, International Conference on Medical Image Computing and Computer-Assisted Intervention.

[5]  Nassir Navab,et al.  Medical Image Computing and Computer-Assisted Intervention - MICCAI 2010, 13th International Conference, Beijing, China, September 20-24, 2010, Proceedings, Part III , 2010, MICCAI.

[6]  Marj Esch TECHNOLOGY PLAN SUMMARY , 2004 .

[7]  E. Rooney,et al.  Correlation full scale wind tunnel and flight measured aerodynamic drag , 1977 .

[8]  Lasse Riis Østergaard,et al.  Active Surface Approach for Extraction of the Human Cerebral Cortex from MRI , 2006, MICCAI.

[9]  Computer-Assisted Intervention,et al.  Medical Image Computing and Computer-Assisted Intervention – MICCAI’99 , 1999, Lecture Notes in Computer Science.

[10]  Rui Liao,et al.  Respiratory motion compensation by model-based catheter tracking during EP procedures , 2010, Medical Image Anal..

[11]  Bertha Fanning Taylor,et al.  C. A. J. , 1953 .

[12]  Michael I. Miga,et al.  Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling , 2009 .

[13]  Z. Azimifar,et al.  Real-time 2D-3D MR cardiac image registration during respiration using extended Kalman filter predictors , 2008, 2008 9th International Conference on Signal Processing.

[14]  S.A.M. Baert,et al.  Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature , 2003, IEEE Transactions on Medical Imaging.

[15]  R. K. Betts,et al.  Cruise Missiles: Technology, Strategy, Politics , 1982 .

[16]  Nikos Paragios,et al.  Guide-Wire Extraction through Perceptual Organization of Local Segments in Fluoroscopic Images , 2010, MICCAI.

[17]  Reinhard Männer,et al.  Reconstruction of 3D Catheter Paths from 2D X-Ray Projections , 1999, MICCAI.

[18]  Thomas Bäck,et al.  Evolutionary computation: comments on the history and current state , 1997, IEEE Trans. Evol. Comput..

[19]  Bart M. ter Haar Romeny,et al.  Detection of Electrophysiology Catheters in Noisy Fluoroscopy Images , 2006, MICCAI.

[20]  Joachim Hornegger,et al.  First steps towards initial registration for electrophysiology procedures , 2011, Medical Imaging.