Characterization of 176Lu background in LSO-based PET scanners
暂无分享,去创建一个
Maurizio Conti | Thomas Carlier | David Townsend | D. Townsend | G. Rosenqvist | L. Eriksson | M. Conti | T. Carlier | H. Rothfuss | Harold Rothfuss | Lars Eriksson | Therese Sjoeholm | Göran Rosenqvist | Therese Sjoeholm
[1] Christopher Kurz,et al. Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring. , 2015, Medical physics.
[2] E. Browne,et al. Nuclear Data Sheets for A = 176 , 1990 .
[3] W. Moses,et al. Effect of 176Lu background on singles transmission for LSO-based PET cameras. , 2002, Physics in medicine and biology.
[4] Michael Tapner,et al. A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres , 2015, European Journal of Nuclear Medicine and Molecular Imaging.
[5] K Wienhard,et al. The ECAT EXACT HR: Performance of a New High Resolution Positron Scanner , 1994, Journal of computer assisted tomography.
[6] D. Townsend,et al. Beyond 18F-FDG: Characterization of PET/CT and PET/MR Scanners for a Comprehensive Set of Positron Emitters of Growing Application—18F, 11C, 89Zr, 124I, 68Ga, and 90Y , 2015, The Journal of Nuclear Medicine.
[7] Maurizio Conti,et al. (90)Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction. , 2015, Medical physics.
[8] Guy Bormans,et al. PET Imaging of Macrophage Mannose Receptor–Expressing Macrophages in Tumor Stroma Using 18F-Radiolabeled Camelid Single-Domain Antibody Fragments , 2015, The Journal of Nuclear Medicine.
[9] C. Bodet-Milin,et al. Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT , 2013, EJNMMI Research.
[10] D. Townsend,et al. Physical and clinical performance of the mCT time-of-flight PET/CT scanner , 2011, Physics in medicine and biology.
[11] D. Horen,et al. Nuclear data sheets for A = 176 , 1976 .
[12] D. Stout,et al. Validation of a GATE Model of $^{176}$Lu Intrinsic Radioactivity in LSO PET Systems , 2011, IEEE Transactions on Nuclear Science.
[13] Michael E. Casey,et al. Development of a daily quality check procedure for the high resolution research tomograph (HRRT) using natural LSO background radioactivity , 2001 .
[14] C. Melcher,et al. Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.
[15] George Loudos,et al. Effect of 176Lu intrinsic radioactivity on dual head PET system imaging and data acquisition, simulation, and experimental measurements. , 2013, Medical physics.
[16] K Parodi,et al. In-beam PET measurements of beta+ radioactivity induced by proton beams. , 2002, Physics in medicine and biology.
[17] Vladimir Panin,et al. Time alignment of time of flight positron emission tomography using the background activity of LSO , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).
[18] L. V. Elmbt,et al. Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres , 2010, European Journal of Nuclear Medicine and Molecular Imaging.
[19] Vladimir Y. Panin,et al. LSO background radiation as a transmission source using time of flight information , 2013 .
[20] L. Eriksson,et al. Monitoring Energy Calibration Drift Using the Scintillator Background Radiation , 2011, IEEE Transactions on Nuclear Science.
[21] H. Murayama,et al. Reduction method for intrinsic random coincidence events from 176Lu in low activity PET imaging , 2014, Radiological Physics and Technology.
[22] M. Senda,et al. Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET , 2005, Annals of nuclear medicine.
[23] Katia Parodi,et al. In-beam PET measurements of β+ radioactivity induced by proton beams , 2002 .
[24] S. Vandenberghe,et al. Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy , 2011, Physics in medicine and biology.
[25] W. Moses,et al. Calibration of a PEM detector with depth of interaction measurement , 2004, IEEE Transactions on Nuclear Science.
[26] R. Holen,et al. Comparison of yttrium-90 SPECT and PET images , 2010 .
[27] R. Salem,et al. Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of Concept , 2011, The Journal of Nuclear Medicine.
[28] Michael V. Green,et al. Characteristics of a pair of small field-of-view LSO scintillation cameras , 1996 .